SCANCOM Commands
Common Commands
See Device Object Common Commands for commands that are common to all device types.
Commands
Command | Description | Parameters |
---|---|---|
Test Communication | When executed, ACM will poll a known OPC item from the device and wait for the response to see if the communication is good. | None |
Retrieve meter config during next history poll | Retrieves meter configuration data during the next history retrieval. | None |
Retrieve History | Requests the retrieval of history records (for all enabled meters). | None |
Ad hoc Retrieval of Hourly History | Triggers ad hoc retrieval of hourly history records for all enabled meters at record position selected. Provide the record position date/time. | Record Position Date/Time |
Ad hoc Retrieval of Daily History | Triggers ad hoc retrieval of daily history records for all enabled meters at record position selected. Provide the record position date/time. | Record Position Date/Time |
Ad hoc Retrieval of Event History | Triggers ad hoc retrieval of event history records for the selected record position. Provide the record position date/time. | Record Position Date/Time |
Ad hoc Retrieval of User Change Log History | Triggers ad hoc retrieval of user change log history records for the selected record position. Provide the record position date/time. | Record Position Date/Time |
Ad hoc Retrieval of DLog History | Triggers ad hoc retrieval of DLog history records for the selected record position. Provide the record position date/time. | Record Position Date/Time |
Retrieve Hourly History | Requests the retrieval of hourly history records (for all enabled meters). | None |
Retrieve Daily History | Requests the retrieval of daily history records (for all enabled meters). | None |
Retrieve Event History | Requests the retrieval of event history records (for all enabled meters). | None |
Retrieve User Change Log History | Requests the retrieval of user change log history records. | None |
Retrieve DLog History | Requests the retrieval of DLog history records. | None |
Reset Hourly Pointer | Clears the hourly retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Meter Number |
Reset Daily Pointer | Clears the daily retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Meter Number |
Reset Event Pointer | Clears the event retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one (if applicable). | Meter Number |
Reset DLog Pointer | Clears the Dlog retrieval position so retrieval starts at the oldest record. Provide the Dlog number in parameter one. Provide the Dlog number in parameter one, or leave blank for all Dlogs. | Meter Number |
Reset User Change Log Pointer | Clears the user change log retrieval position so retrieval starts at the oldest record. | Meter Number |
Set Hourly Record Pointer | Moves the saved hourly retrieval position to the specified position. Provide the meter number in parameter one, or leave blank for all meters. Provide the record position date/time. | Meter Number Record Position Date/Time |
Set Daily Record Pointer | Moves the saved daily retrieval position to the specified position. Provide the meter number in parameter one, or leave blank for all meters. Provide the record position date/time. | Meter Number Record Position Date/Time |
Set Event Record Pointer | Moves the saved event retrieval position to the specified position. Provide the record position date/time. | Record Position Date/Time |
Set User Change Log Record Pointer | Moves the saved event retrieval position to the specified position. Provide the record position date/time. | Record Position Date/Time |
Set DLog Record Pointer | Moves the saved DLog retrieval position to the specified position. Provide the DLog number in parameter one, or leave blank for all DLogs. Provide the record position date/time. | DLog Number Record Position Date/Time |
Time Sync | Causes a comparison of the date and time in the device to the host date and time. Once compared, the configured rules of the selected time sync object will be applied - including time zone and daylight saving options | None |