ROC Commands
ROC Commands
Common Commands
See Device Object Common Commands for commands that are common to all device types.
Commands
Command | Description | Parameters |
---|---|---|
Test Communication | When executed, ACM will poll a known OPC item from the device and wait for the response to see if the communication is good. | None |
Retrieve meter config during next history poll | Retrieves meter configuration data for all meters during the next history retrieval. | None |
Time Sync | Causes a comparison of the date and time in the device to the host date and time. Once compared, the configured rules of the selected time sync object will be applied - including time zone and daylight saving options. | None |
Reinitialize | Reinitializes OPC items, rebuilds poll message, and rereads field device configuration. | None |
Retrieve History | Requests the retrieval of all enabled archive record types. | None |
Reset Hourly Pointer | Clears the hourly retrieval position so retrieval starts at the oldest record. | None |
Reset Daily Pointer | Clears the daily retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one. | None |
Reset Minute Pointer | Clears the minute retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one. | None |
Reset Event Pointer | Clears the event retrieval position so retrieval starts at the oldest record. | None |
Reset Alarm Pointer | Clears the alarm retrieval position so retrieval starts at the oldest record. | None |
Reset Batch Pointer | Clears the batch retrieval position so retrieval starts at the oldest record. | None |
Reset Extended Pointer | Clears the extended retrieval position so retrieval starts at the oldest record. | None |
Move Hourly Pointer Back | Moves the saved hourly retrieval position to an older record. Enter the number of records to move back. | Record Count |
Move Daily Pointer Back | Moves the saved daily retrieval position to an older record. Enter the number of records to move back. | Record Count |
Skip Hourly Records | Moves the saved hourly retrieval position forward. Enter the number of records to skip. | Record Count |
Skip Daily Records | Moves the saved daily retrieval position forward. Enter the number of records to skip. | Record Count |
Document Archive History Point Maps | Write the internal archive history point maps to the server machine file "C:\ProgramData\AutoSol\Communication Manager\7\RocInternalArchiveMapDocumentation.txt" | None |
, multiple selections available,
Related content
Device Protocols
Device Protocols
Read with this
BenchMark Commands
BenchMark Commands
More like this
Protocols
Protocols
Read with this
Romet Commands
Romet Commands
More like this
ROC
Read with this
Eagle Commands
Eagle Commands
More like this