Flow Automation Commands
Common Commands
See Device Object Common Commands for commands that are common to all device types.
Commands
Command | Description | Parameters |
|---|---|---|
Test Communication | When executed, ACM will poll a known OPC item from the device and wait for the response to see if the communication is good. | None |
Retrieve meter config during next history poll | Retrieves meter configuration data for all meters during the next history retrieval. | None |
Retrieve History | Requests the retrieval of all enabled archive record types (for all enabled meters) | None |
Reset Hourly Pointer | Clears the hourly retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Meter Number |
Reset Daily Pointer | Clears the daily retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Meter Number |
Reset Event Pointer | Clears the event retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Meter Number |
Reset Alarm Pointer | Clears the alarm retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Meter Number |
Move Hourly Pointer Back | Moves the saved hourly retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number | Meter Number Record Count |
Move Daily Pointer Back | Moves the saved daily retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number | Meter Number Record Count |
Move Event | Moves the saved event retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of records | Meter Number Record Count |
Move Alarm | Moves the saved alarm retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of records | Meter Number Record Count |
Skip Hourly Records | Moves the saved hourly retrieval position forward. Provide the record count in parameter one, or leave blank for all meters. Enter the number of records to | Meter Number Record Count |
Skip Daily Records | Moves the saved daily retrieval position forward. Provide the record count in parameter one, or leave blank for all meters. Enter the number of records to skip. | Meter Number Record Count |
Skip Event Records | Moves the saved event retrieval position forward. Provide the record count in parameter one, or leave blank for all meters. Enter the number of records to skip. | Meter Number Record Count |
Skip Alarm Records | Moves the saved alarm retrieval position forward. Provide the record count in parameter one, or leave blank for all meters. Enter the number of records to skip. | Meter Number Record Count |
Time Sync | Causes a comparison of the date and time in the device to the host date and time. Once compared, the configured rules of the selected time sync object will be applied - including time zone and daylight saving options. | None |