Kimray Commands

Common Commands

See Device Object Common Commands for commands that are common to all device types.

Commands

CommandDescriptionParameters

Test Communication

When executed, ACM will poll a known OPC item from the device and wait for the response to see if the communication is good.None
Retrieve meter config during next history pollRetrieves meter configuration data for all meters during the next history retrieval.None
Retrieve CTD HistoryRequests the retrieval of CTD records (for all enabled meters).None
Retrieve ProductionRequests the retrieval of production records.None
Retrieve Trend HourlyRequests the retrieval of trend hourly records.None
Retrieve Trend DailyRequests the retrieval of trend daily records.None
Retrieve AnalogRequests the retrieval of analog records.None
Reset CTD History (Hourly/Daily) PointerClears the CTD history (hourly/daily) retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all metersMeter Number
Reset Production PointerClears the production records retrieval position so retrieval starts at the oldest records. Provide the Flow Computer Number in parameter one, or leave blank for all.Flow Computer Number
Reset Trend Hourly PointerClears the trend hourly records retrieval position so retrieval starts at the oldest records. Provide the Trend Number in parameter one, or leave blank for all.Trend Number
Reset Trend Daily PointerClears the trend daily records retrieval position so retrieval starts at the oldest records. Provide the Trend Number in parameter one, or leave blank for all.Trend Number
Reset Analog PointerClears the analog records retrieval position so retrieval starts at the oldest records. Provide the Analog Number in parameter one, or leave blank for all.Analog Number
Move CTD History Pointer Backward (Hourly/Daily)Moves the saved CTD history (hourly/daily) retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of hours to move back for parameter two.

Meter Number

Hours Count

Move Production Pointer BackwardMoves the saved production pointer retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of seconds to move back for parameter two.

Meter Number

Seconds Count

Move Trend Hourly Pointer BackwardMoves the saved trend hourly pointer retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of hours to move back for parameter two.

Meter Number

Hours Count

Move Trend Daily Pointer BackwardMoves the saved trend daily pointer retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of days to move back for parameter two.

Meter Number

Day Count

Move Analog Pointer BackwardMoves the saved analog pointer retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of hours to move back for parameter two.

Meter Number

Hours Count

Skip CTD History Records (Hourly/Daily)Moves the saved CTD history (hourly/daily) retrieval position forward. Provide the record count in parameter one or leave blank for all meters. Enter the number of records to skip.

Meter Number

Records Count

Skip Production RecordsMoves the saved production records retrieval position forward. Provide the record count in parameter one or leave blank for all meters. Enter the number of records to skip.

Meter Number

Records Count

Skip Trend Hourly RecordsMoves the saved trend hourly records retrieval position forward. Provide the record count in parameter one or leave blank for all meters. Enter the number of records to skip.

Meter Number

Hours Count

Skip Trend Daily RecordsMoves the saved trend daily records retrieval position forward. Provide the record count in parameter one or leave blank for all meters. Enter the number of records to skip.

Meter Number

Hours Count

Skip Analog RecordsMoves the saved analog records retrieval position forward. Provide the record count in parameter one or leave blank for all meters. Enter the number of records to skip.

Meter Number

Hours Count

Time SyncCauses a comparison of the date and time in the device to the host date and time. Once compared, the configured rules of the selected time sync object will be applied - including time zone and daylight saving options.None

For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.