Kimray Commands

Kimray Commands

Common Commands

See Device Object Common Commands for commands that are common to all device types.

Commands

Command

Description

Parameters

Command

Description

Parameters

Test Communication

When executed, ACM will poll a known OPC item from the device and wait for the response to see if the communication is good.

None

Retrieve meter config during next history poll

Retrieves meter configuration data for all meters during the next history retrieval.

None

Retrieve CTD History

Requests the retrieval of CTD records (for all enabled meters).

None

Retrieve Production

Requests the retrieval of production records.

None

Retrieve Trend Hourly

Requests the retrieval of trend hourly records.

None

Retrieve Trend Daily

Requests the retrieval of trend daily records.

None

Retrieve Analog

Requests the retrieval of analog records.

None

Reset CTD History (Hourly/Daily) Pointer

Clears the CTD history (hourly/daily) retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters

Meter Number

Reset Production Pointer

Clears the production records retrieval position so retrieval starts at the oldest records. Provide the Flow Computer Number in parameter one, or leave blank for all.

Flow Computer Number

Reset Trend Hourly Pointer

Clears the trend hourly records retrieval position so retrieval starts at the oldest records. Provide the Trend Number in parameter one, or leave blank for all.

Trend Number

Reset Trend Daily Pointer

Clears the trend daily records retrieval position so retrieval starts at the oldest records. Provide the Trend Number in parameter one, or leave blank for all.

Trend Number

Reset Analog Pointer

Clears the analog records retrieval position so retrieval starts at the oldest records. Provide the Analog Number in parameter one, or leave blank for all.

Analog Number

Move CTD History Pointer Backward (Hourly/Daily)

Moves the saved CTD history (hourly/daily) retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of hours to move back for parameter two.

Meter Number

Hours Count

Move Production Pointer Backward

Moves the saved production pointer retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of seconds to move back for parameter two.

Meter Number

Seconds Count

Move Trend Hourly Pointer Backward

Moves the saved trend hourly pointer retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of hours to move back for parameter two.

Meter Number

Hours Count

Move Trend Daily Pointer Backward

Moves the saved trend daily pointer retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of days to move back for parameter two.

Meter Number

Day Count

Move Analog Pointer Backward

Moves the saved analog pointer retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of hours to move back for parameter two.

Meter Number

Hours Count

Skip CTD History Records (Hourly/Daily)

Moves the saved CTD history (hourly/daily) retrieval position forward. Provide the record count in parameter one or leave blank for all meters. Enter the number of records to skip.

Meter Number

Records Count

Skip Production Records

Moves the saved production records retrieval position forward. Provide the record count in parameter one or leave blank for all meters. Enter the number of records to skip.

Meter Number

Records Count

Skip Trend Hourly Records

Moves the saved trend hourly records retrieval position forward. Provide the record count in parameter one or leave blank for all meters. Enter the number of records to skip.

Meter Number

Hours Count

Skip Trend Daily Records

Moves the saved trend daily records retrieval position forward. Provide the record count in parameter one or leave blank for all meters. Enter the number of records to skip.

Meter Number

Hours Count

Skip Analog Records

Moves the saved analog records retrieval position forward. Provide the record count in parameter one or leave blank for all meters. Enter the number of records to skip.

Meter Number

Hours Count

Time Sync

Causes a comparison of the date and time in the device to the host date and time. Once compared, the configured rules of the selected time sync object will be applied - including time zone and daylight saving options.

None