Kimray History Record Formats
Overview
History records can be retrieved from the RTU and stored in various formats. The sections below describe the field names used for the various history record types.
Analog Record Format
Field Name | Description |
---|---|
Date | The date of the record in YYYY/MM/DD format. |
StartTime | Record start time |
EndTime | Record end time |
AnalogRecordNum | Analog Record Number |
AnalogRecordFlag | Bit map •      0 = History is being stored for this analog •      1 = History is flow-dependent •      2 = Value is the average of square root |
AnalogRecordF.C. | Analog Record attached Flow Computer |
DailyValue | Daily Value |
HourlyValue_0 | Hourly Value for 00:00 |
HourlyValue_1 | Hourly Value for 01:00 |
HourlyValue_2 | Hourly Value for 02:00 |
HourlyValue_3 | Hourly Value for 03:00 |
HourlyValue_4 | Hourly Value for 04:00 |
HourlyValue_5 | Hourly Value for 05:00 |
HourlyValue_6 | Hourly Value for 06:00 |
HourlyValue_7 | Hourly Value for 07:00 |
HourlyValue_8 | Hourly Value for 08:00 |
HourlyValue_9 | Hourly Value for 09:00 |
HourlyValue_10 | Hourly Value for 10:00 |
HourlyValue_11 | Hourly Value for 11:00 |
HourlyValue_12 | Hourly Value for 12:00 |
HourlyValue_13 | Hourly Value for 13:00 |
HourlyValue_14 | Hourly Value for 14:00 |
HourlyValue_15 | Hourly Value for 15:00 |
HourlyValue_16 | Hourly Value for 16:00 |
HourlyValue_17 | Hourly Value for 17:00 |
HourlyValue_18 | Hourly Value for 18:00 |
HourlyValue_19 | Hourly Value for 19:00 |
HourlyValue_20 | Hourly Value for 20:00 |
HourlyValue_21 | Hourly Value for 21:00 |
HourlyValue_22 | Hourly Value for 22:00 |
HourlyValue_23 | Hourly Value for 23:00 |
DailyMinValue | Daily Min Value |
DailyMinTime | Time when reached daily min value |
DailyMaxValue | Daily Max Value |
DailyMaxTime | Time when reached daily max value |
Production Record Format
Field Name | Description |
---|---|
EventSequenceNumber | Event sequence number |
EventType | 1.   Unknown 2.   RTU Powered Down 3.   RTU Powered Up 4.   Maintenance Mode Entered 5.   Maintenance Mode Exited 6.   PROcontrol Turned Off 7.   PROcontrol Turned On 8.   Valve Opened 9.   Valve Failed - Valve is Closed 10. Bypass Opened 11. End Lift 12. Valve Closed 13. Valve Failed – Valve is Open 14. End of Contract Day |
Date | Event occurred date |
Time | Event occurred time |
CasingPress/NumOfLift | Casing Pressure |
TurbingPress/NumOfBypasses | Tubing Pressure |
LinePress/NumOfLiftFail | Line Pressure |
DiffPress/NumOfProductionEvent | Different Pressure |
FlwoRate | Flow Rate |
ValveTime | Valve open/close time |
VolumeProduced | Volume Produced |
MiscellaneousEventStatus | Other status |
Hourly/Daily/Trend Record Format
Field Name | Description |
---|---|
RTUName | RTU Name |
RTUGroup | RTU Group |
RTUAddress | RTU Address |
TrendNumber | Trend Number |
AnalogRecord | Analog Record Number |
Date | Date |
Time | Time |
TrendPointValue | Trend Point Value |