Modbus Prosoft Configuration

See the Common Device Configuration guide for assistance configuring the General, Options, Details, and Logging tabs. See the Connection/Schedule page for assistance with the Connection tab.

Device Tab

See the Common Modbus Configuration (Device Tab) page.

Device Tab Register Set Note

This should be set to the “ProSoft Register Set” for non-enhanced modules, and “Prosoft Enhanced Register Set” for enhanced modules. Pre-built Register Sets can be imported from ‘C:\Program Files(x86)\AutoSol\Communication Manager\Client\Templates’ by selecting the ‘Import_ModbusRegisterSets.txt’ import file.

Archive Collection Tab

Collection Priority

  • Low (Default).Queues up with other Low priority items.
  • Medium. Interrupts Low priority items, and queues up with other Medium priority items.
  • High. Interrupts Medium and Low priority items, and queues up with other High priority items.

Collection Intervals

Select the desired Interval relating to the Schedule object assigned on the Connection tab. Record collection will occur at a frequency based on the configuration of this interval.

Process Event Queue (Events and Alarms for non-Enhanced)

Default = Not selected. For non-enhanced: Collect the events and alarms. For enhanced: Collect the events.

Event Archive

Click  to select or create a Configurable Archive. See the Configurable Archive section for more details.

Set download complete site signal, or Commit event session, after retrieving events

Default = Not selected. For non-enhanced flow computers, set the site signal register. For enhanced flow computers, commit the event session.

Event Site Signal Register

Default = 200. Site signal register for acknowledging events. Only used for non-Enhanced Flow Computers.

Process Alarm Queue (Enhanced Only)

Default = Not selected. Select to enable Enhanced Alarm collection. Enhanced Flow Computer only.

Commit alarm session after retrieving alarms

Default = Not selected. Select to commit the alarm session and update the index on the flow computer. Enhanced Flow Computer only.

Alarm Archive

Click  to select or create a Configurable Archive. See the Configurable Archive section for more details.

Meter Runs Tab

Meter 1-16

Click  to select or create the Meter Object assigned for the selected meter run. See the Meter section for more details.

Collect Hourly

Default = Not selected. Select to configure and collect.

Hourly Archive

Click  to select or create a Configurable Archive. See the Configurable Archive section for more details.

Hourly Record Size

Default = 30. The size in WORDs of each hourly record. Only Enhanced flow computer supports values above 40.

Extended File Size (Hourly)

Default = 0. The size in bytes of each extended hourly record.

Collect Daily

Default = Not selected. Select to configure and collect.

Daily Archive

Click  to select or create a Configurable Archive. See the Configurable Archive section for more details.

Daily Record Size

Default = 30. The size in WORDs of each daily record. Only Enhanced flow computer supports values above 40.

Extended File Size (Daily)

Default = 0. The size in bytes of each extended daily record.

Convert Specific Gravity

Default = Not selected. Select to convert the meter's specific gravity value using the equation: outputSG = ((141.5 / inputSG) * 999.016) - 131.5

Important Information

Volume and Energy values are frequently archived in two parts (the whole number value and the fraction). If the archive is configured to store these (or any other values) in two parts, any scaling required must be applied to both parts of the value.

The selected value for the Hourly and Daily record size must be equal or greater than the total number of bytes of data in the selected Advanced Archive Configuration object.

Sample:

If the device has 30 bytes of data in each archive, 30 will be selected as the record size.

If the device has 34 bytes of data in each archive 40 will be selected as the record size since there is not a 34 selection option.

For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.