Hex Repeater Configuration
Recommended Configuration Steps
The Hex Repeater device relies on a template that defines what commands can be sent to the device and what items are available for each command. A template object must be assigned on the Template Tab of this configuration. Review the Template guide to understand how this file is structured and how it can be modified if needed.
Device Tab
Address
Default = 1. Address of the target field device. The hex value for the address will appear to the right.
Location Multiplier
Default = 0. Location Multiplier for the field device. The hex value appearing to the right is a calculated value, not the equivalent of the decimal value entered.
User ID
Default = ACM. This is the identification string to use for configuration download commands.
If required, enter the Hop Configuration Addresses and Location Multipliers of any RTU in the path to the target field device (value between 0 and 255). Set any unused hop addresses and location multipliers to zero.
Note
If configuring a Hop Address, you must also enter a Location Multiplier. The hops are used in sequential order, and the first pair that has a zero in either the hop address or location multiplier marks the end of the hop path.
Scheduled Scan Interval
Default = Interval 1. Select the desired collection interval relating to the Schedule object assigned on the Connection tab. Collection occurs on the frequency of this interval.
Scheduled Scan Priority
- Low.Queues up with other Low priority items.
- Medium (Default). Interrupts Low priority items, and queues up with other Medium priority items.
- High. Interrupts Medium and Low priority items, and queues up with other High priority items.
Enable Enhanced Logging Mode
Default = Not selected. Selecting this will configure the polling engine to log additional traffic status information for outgoing and incoming messages to facilitate troubleshooting for difficult communication situations. Only use this feature for short term troubleshooting as it can increase log size considerably.
Example
An example of the information that is logged when ‘Enable Enhanced Logging Mode’ is enabled is shown below:
MSGDBG Item: "AnalogCalibration.Value2 - Digital Value #1"; Value: "819"; Quality = 192; Type = 0x0012; Offset: 3; Length: 2; Hex: 03 33
This Includes:
- The item Description
- The item Value
- The item Quality
- The item data type
- The offset (in bytes) of the item’s data in the receive data buffer
- The length, or number of bytes, that contain the item’s data
- The hexadecimal bytes that make up the item’s value.
Template Tab
Template Name
Click to select or create a Template. See the Template section for more details.
Note
Template objects are created in ACM just like any other ACM object type. Once created, the template xml file is imported into the template object and stored in ACM’s configuration database, so the template xml file is not needed for ACM to run and communicate with Hex Repeater devices.
Action Sequence Group
Modify the Action Sequence Group, if applicable. The Action Sequence Group Enable field will list the name and enabled status of each action group available in the template. Action Sequence Groups are a list of pre-defined commands that are executed (reads or writes) when a “Scan” poll finds that a particular item’s value should trigger the action sequence. Action sequence groups can be disabled to prevent queuing new polls as a result of the data read during a “Scan” poll. Template-defined action sequences will not be queued if the associated Action Sequence Group is disabled.
Action Sequence Groups can also be disabled dynamically by information provided in the template file. Action Sequence Groups have an ‘inhibit’ property that can prevent their execution if specific values are found in a Scan command response. For example, the ‘Lost All Data’ bit can be used to inhibit action sequences related to reading configuration data from the device.
Time Sync Tab
See Common Time Sync Tab for general Time Sync configuration details.
Archive Collection Tab
Maximum Records per Poll
Default = 24. This limits the number of history records retrieved at one time from any given log during a poll cycle.
Enable the appropriate Event Log Collections.
Note
Event log collection is typically disabled and only enabled for major central delivery points. RTU event log data is published as FLOWCAL CFX string event data and is not required for CFX numeric events.
Meter Runs Tab
Meter 1-4
Click to select or create the Meter Object assigned to the selected meter run. See the Meter section for more details.
Station Meter
Click to select or create the Meter Object assigned to the device at the Station level. All historical log data is associated with a meter object in ACM. For data that is not specifically EFM-related, a ‘Station Meter’ is used as the meter object. The Hex Repeater uses the Station Meter for logs such as Production Cycle and Control Logs. See the Meter section for more details.
Note
No Advanced Meter Configuration object is necessary and the settings in the Meter object can be blank. However, a Meter object must be assigned for publishing to work.
Meter Contract Hour 1-4
Default = 0. These values are used only if the contract hour isn’t read from the device.
For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.