Dresser OPC Items
Dresser OPC Items
Standard Items
Protocol Items
Item | Data Type | Type Command | Description |
---|---|---|---|
AccumCorrVolCurrDay | VT_I4 | '*' Consumption Data | Accumulated Corrected Volume Current Day |
AccumCorrVolCurrMo | VT_I4 | '*' Consumption Data | Accumulated Corrected Volume Current Month |
AccumCorrVolPrevDay | VT_I4 | '*' Consumption Data | Accumulated Corrected Volume Previous Day |
AccumCorrVolPrevMo | VT_I4 | '*' Consumption Data | Accumulated Corrected Volume Previous Month |
Alarm_HiSpareLimit | VT_R4 | '[' Alarm Settings | Spare Hi Alarm Limit |
Alarm_LoSpareLimit | VT_R4 | '[' Alarm Settings | Spare Low Alarm Limit |
Alarm_OnLCD | VT_UI1 | '[' Alarm Settings | Alarms on LCD select bit mask based on the alarm register |
Alarm_PulseOutput | VT_UI1 | '[' Alarm Settings | Alarms on Pulse outputs select bit mask based on the alarm register |
Alarm_Selection | VT_BOOL | '[' Alarm Settings | Alarm select Enabled should always be true except during config write |
AtmosPressure | VT_R4 | 'r' EEPROM Read | Atmospheric Pressure |
BasePress | VT_R4 | 'r' EEPROM Read | Base Pressure |
BaseTemp | VT_R4 | 'r' EEPROM Read | Base Temperature |
BattVoltage | VT_UI4 | 'l' Live Data | Number without decimal place |
ContractStartTime | VT_UI4 | 'r' EEPROM Read | |
CorrDisplayDigits | VT_UI1 | 'r' EEPROM Read | Correction |
CorrFactor | VT_R4 | 'l' Live Data | Correction Factor |
CorrPulseOutput | VT_UI2 | 'r' EEPROM Read | |
CorrPulseOutputProve | VT_UI2 | 'r' EEPROM Read | |
CorrResidual | VT_R4 | 'l' Live Data | Corrected Residual |
CorrVolMultiplier | VT_UI1 | 'r' EEPROM Read | |
CorrVolMultProve | VT_UI1 | 'r' EEPROM Read | |
CorrVolume | VT_I4 | 'l' Live Data | Corrected Volume |
CurrentMeterCoEfficient | VT_R4 | '|' Secondary Live Data | Current Value of Meter Coefficient (Current Avg Value) |
DailyConsAlarmOccurred | VT_BOOL | 'l' Live Data | Daily Consumption Alarm Occurred |
DailyConsAlarmPresent | VT_BOOL | 'l' Live Data | Daily Consumption Alarm Present |
DataMessageSize | VT_UI1 | 'D' Data Packet Length | |
DateLastConsAlarm | VT_UI4 | '*' Consumption Data | |
DateTime | VT_BSTR | 'l' Live Data | |
DialOutAlarmEnable | VT_BOOL | '{' Dial-Out Settings | |
DialOutAlarmFlag | VT_UI1 | '{' Dial-Out Settings | |
DialOutAlarmPhoneNumber | VT_BSTR | '{' Dial-Out Settings | |
DialOutAlarmSelection | VT_UI1 | '{' Dial-Out Settings | |
DialOutAlarmTime | VT_UI2 | '{' Dial-Out Settings | |
DialOutFaultEnable | VT_BOOL | '{' Dial-Out Settings | |
DialOutFaultFlag | VT_UI1 | '{' Dial-Out Settings | |
DialOutFaultPhoneNumber | VT_BSTR | '{' Dial-Out Settings | |
DialOutFaultSelection | VT_UI1 | '{' Dial-Out Settings | |
DialOutFaultTime | VT_UI2 | '{' Dial-Out Settings | |
DialOutModemBaudRate | VT_UI1 | '{' Dial-Out Settings | |
DPCommonModeOffsetAdj | VT_R4 | '|' Secondary Live Data | DP Common Mode Offset Adjustment (bar) |
DPCommonModeOffsetAdjPeriod | VT_I4 | '|' Secondary Live Data | DP Common Mode Offset Adjustment Period (date/time) |
EnabledorDisabled | VT_UI1 | 'r' EEPROM Read | |
EnableUorC | VT_UI1 | 'r' EEPROM Read | |
Feature_AlarmDialOut | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_Alarms | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_DataLogging | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_DigiInTerm | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_DigiOutTerm | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_DPTransducer | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_DualPressTransducers | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_Email | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_ExtFaultsAndAlarms | VT_BOOL | 'b' Read-Only Firmware Features | Extended Faults And Alarms |
Feature_ExtLoggingMeasurements | VT_BOOL | 'b' Read-Only Firmware Features | Extended Logging Measurements |
Feature_ExtLoggingMemory | VT_BOOL | 'b' Read-Only Firmware Features | Extended Logging Memory |
Feature_FaultDialOut | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_GSMModem | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_LivePressure | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_MeterDiagnostics | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_MeterTrim | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_ModemModelSel | VT_BOOL | 'b' Read-Only Firmware Features | Modem Model Selection |
Feature_Printer | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_SMS | VT_BOOL | 'b' Read-Only Firmware Features | |
Feature_TelemTermSel | VT_BOOL | 'b' Read-Only Firmware Features | Telemetry Terminal Selection |
Feature_ZTable | VT_BOOL | 'b' Read-Only Firmware Features | |
FirmwareRevLevel | VT_BSTR | 'f' Firmware Request | |
FixedPressFactor | VT_R4 | 'r' EEPROM Read | |
FixedSupercompFactor | VT_R4 | 'r' EEPROM Read | |
FixedTemperature | VT_R4 | 'r' EEPROM Read | |
FlowRate | VT_R4 | 'l' Live Data | Flow Rate |
FlowSense | VT_UI1 | 'r' EEPROM Read | Flow Sense 1 = Forward - Reverse 2= Reverse - Forward 3= Reserve 4= Forward 5= Forward + Reverse |
GMSAdditionalTurnOffTime | VT_UI4 | '(' Modem Settings | |
GMSAdditionalTurnOnTime | VT_UI4 | '(' Modem Settings | |
GMSAlarmDialOutType | VT_UI1 | '(' Modem Settings | |
GMSFaultDialOutType | VT_UI1 | '(' Modem Settings | |
GMSModemType | VT_UI1 | '(' Modem Settings | |
GMSTurnOffTime | VT_UI4 | '(' Modem Settings | |
GMSTurnOnTime | VT_UI4 | '(' Modem Settings | |
GSMPowerType | VT_UI1 | '(' Modem Settings | |
HighestDailyVolCurrMo | VT_I4 | '*' Consumption Data | |
HighestDailyVolPrevMo | VT_I4 | '*' Consumption Data | |
HighFlowAlarmLimit | VT_R4 | '[' Alarm Settings | |
HighFlowAlarmOccurred | VT_BOOL | 'l' Live Data | High Flow Alarm Occurred |
HighFlowAlarmPresent | VT_BOOL | 'l' Live Data | High Flow Alarm Present |
HighPressAlarmLimit | VT_R4 | '[' Alarm Settings | |
HighPressAlarmOccurred | VT_BOOL | 'l' Live Data | High Pressure Alarm Occurred |
HighPressAlarmPresent | VT_BOOL | 'l' Live Data | High Pressure Alarm Present |
HighTempAlarmLimit | VT_R4 | '[' Alarm Settings | |
HighTempAlarmOccurred | VT_BOOL | 'l' Live Data | High Temperature Alarm Occurred |
HighTempAlarmPresent | VT_BOOL | 'l' Live Data | High Temperature Alarm Present |
IntegralOrID | VT_UI1 | 'h' Hardware Settings | 0= Wiegand 1= Standard |
InternalFaultOccurred | VT_BOOL | 'l' Live Data | Internal Fault Occurred |
InternalFaultPresent | VT_BOOL | 'l' Live Data | Internal Fault Present |
LCDASelect | VT_UI1 | 'r' EEPROM Read | |
LCDBSelect | VT_UI1 | 'r' EEPROM Read | |
LCDCSelect | VT_UI1 | 'r' EEPROM Read | |
LCDDefault | VT_UI4 | 'r' EEPROM Read | |
LCDEnable | VT_UI4 | 'r' EEPROM Read | |
LinePress | VT_R4 | 'l' Live Data | Pressure |
LinePressFaultOccurred | VT_BOOL | 'l' Live Data | Line Pressure Fault Occurred |
LinePressFaultPresent | VT_BOOL | 'l' Live Data | Line Pressure Fault Present |
LowBattFaultOccurred | VT_BOOL | 'l' Live Data | Low Battery Fault Occurred |
LowBattFaultPresent | VT_BOOL | 'l' Live Data | Low Battery Fault Present |
LowFlowAlarmLimit | VT_R4 | '[' Alarm Settings | |
LowFlowAlarmOccurred | VT_BOOL | 'l' Live Data | Low Flow Alarm Occurred |
LowFlowAlarmPresent | VT_BOOL | 'l' Live Data | Low Flow Alarm Present |
LowPressAlarmLimit | VT_R4 | '[' Alarm Settings | |
LowPressAlarmOccurred | VT_BOOL | 'l' Live Data | Low Pressure Alarm Occurred |
LowPressAlarmPresent | VT_BOOL | 'l' Live Data | Low Pressure Alarm Present |
LowTempAlarmLimit | VT_R4 | '[' Alarm Settings | |
LowTempAlarmOccurred | VT_BOOL | 'l' Live Data | Low Temperature Alarm Occurred |
LowTempAlarmPresent | VT_BOOL | 'l' Live Data | Low Temperature Alarm Present |
MaxDailyConsumption | VT_UI4 | 'r' EEPROM Read | |
MeterDiagDresserCalcVal | VT_R4 | '|' Secondary Live Data | Meter Diagnostic Dresser Calculator Value |
MeterDiagLowFlowLockupThres | VT_R4 | '|' Secondary Live Data | Meter Diagnostic Low Flow Lockup Threshold (bar) |
MeterDiagPresLearntPeriod | VT_I4 | '|' Secondary Live Data | Meter Diagnostic Present Learnt Period |
MeterDiagStatus | VT_UI1 | '|' Secondary Live Data | Meter Diagnostic Status |
MeterDisplay | VT_BSTR | 'r' EEPROM Read | |
MeterSiteID | VT_BSTR | 'r' EEPROM Read | |
MeterSize | VT_UI1 | 'r' EEPROM Read | |
MeterType | VT_UI1 | 'r' EEPROM Read | |
MonitorPressFaultOccurred | VT_BOOL | 'l' Live Data | Pressure Monitor Fault Occurred |
MonitorPressFaultPresent | VT_BOOL | 'l' Live Data | Pressure Monitor Fault Present |
OccurDigInput | VT_BOOL | 'l' Live Data | Digital Input/Tamper Occurred |
OccuredAlarms | VT_UI1 | 'l' Live Data | Occurred Alarms |
OccuredFaults | VT_UI1 | 'l' Live Data | Occurred Faults |
OutputTermMode | VT_UI1 | 'r' EEPROM Read | |
OutputTermPolarity | VT_UI1 | 'r' EEPROM Read | |
PasswordEnabled | VT_BOOL | 'p' Password Enable Query | |
PCBRev | VT_UI1 | 's' PCB Revision Request | |
PresentAlarms | VT_UI1 | 'l' Live Data | Present Alarms |
PresentDigInput | VT_BOOL | 'l' Live Data | Digital Input/Tamper Present |
PresentFaults | VT_UI1 | 'l' Live Data | Present Faults |
PressConversion | VT_R4 | 'r' EEPROM Read | |
PressDecimal | VT_UI1 | 'r' EEPROM Read | |
PressDisplay | VT_UI1 | 'r' EEPROM Read | |
PressFactor | VT_R4 | 'r' EEPROM Read | |
PressLCDLabel | VT_BSTR | 'r' EEPROM Read | |
PressMode | VT_UI1 | 'r' EEPROM Read | Pressure Mode 0=Live 1=Fixed |
PressUnits | VT_UI1 | 'r' EEPROM Read | Pressure Units 1=Bar 2=PSI 3=Other |
PressureMonitor | VT_R4 | '|' Secondary Live Data | Pressure Monitor |
PressureMonitorRaw | VT_R4 | '|' Secondary Live Data | Pressure Monitor (raw) |
PressXducerRange | VT_UI1 | 'h' Hardware Settings | Pressure Range |
PressXducerType | VT_UI1 | 'h' Hardware Settings | Pressure Transducer Type |
ProverCorrDigits | VT_UI1 | 'r' EEPROM Read | |
ProverStartedFaultOccurred | VT_BOOL | 'l' Live Data | Prover Started Fault Occurred |
ProverStartedFaultPresent | VT_BOOL | 'l' Live Data | Prover Started Fault Present |
ProverStoppedFaultOccurred | VT_BOOL | 'l' Live Data | Prover Stopped Fault Occurred |
ProverStoppedFaultPresent | VT_BOOL | 'l' Live Data | Prover Stopped Fault Present |
ProverUncorrDigits | VT_UI1 | 'r' EEPROM Read | |
PulseRevolution | VT_UI1 | 'r' EEPROM Read | |
PulseWidth | VT_R4 | 'r' EEPROM Read | |
RawPress | VT_R4 | 'l' Live Data | Raw Pressure |
RawTemp | VT_R4 | 'l' Live Data | Raw Temperature |
Revolution2 | VT_I2 | 'r' EEPROM Read | |
RevPerUnitVolume | VT_UI4 | 'r' EEPROM Read | |
SerialNo | VT_UI4 | 'n' Serial Number | Unit Serial Number |
SupercompFactor | VT_R4 | 'l' Live Data | Z Factor/ Super Compress-ability |
SupercompMode | VT_UI1 | 'r' EEPROM Read | Super Compress-ability Mode |
TelemetryCorr | VT_UI1 | 'r' EEPROM Read | |
TelemetryEnable | VT_UI1 | 'r' EEPROM Read | |
TelemetryFault | VT_UI1 | 'r' EEPROM Read | |
TelemetryUncorr | VT_UI1 | 'r' EEPROM Read | |
Temp | VT_R4 | 'l' Live Data | Temperature |
TempFaultOccurred | VT_BOOL | 'l' Live Data | Temperature Fault Occurred |
TempFaultPresent | VT_BOOL | 'l' Live Data | Temperature Fault Present |
TempMode | VT_UI1 | 'r' EEPROM Read | Temperature Mode 0=Live 1=Fixed |
TempUnits | VT_UI1 | 'r' EEPROM Read | Temperature Units 1=C 2=F |
TrimFactor | VT_R4 | '|' Secondary Live Data | Trim Factor (value 1.0 if Trim not selected) |
TrimTableCorrFactor1 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor10 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor11 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor12 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor13 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor14 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor15 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor16 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor2 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor3 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor4 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor5 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor6 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor7 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor8 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableCorrFactor9 | VT_R4 | 'g' Read Trim Table | Trim Table Correction Factor |
TrimTableEntries | VT_UI1 | 'g' Read Trim Table | Number of entries in Trim Table (0-16) |
TrimTableQmax | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax1 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax10 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax11 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax12 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax13 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax14 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax15 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax16 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax2 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax3 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax4 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax5 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax6 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax7 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax8 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableQmax9 | VT_R4 | 'g' Read Trim Table | % of QMax |
TrimTableSel | VT_UI1 | 'g' Read Trim Table | Trim Table Selected |
TrimTableTrimFactorLive | VT_R4 | 'g' Read Trim Table | Trim Table Trim Factor (Live Current Value) |
UncorrDisplayDigits | VT_UI1 | 'r' EEPROM Read | |
UncorrFaultVolume | VT_I4 | 'l' Live Data | Uncorrected Under Fault |
UncorrPulseOutput | VT_UI2 | 'r' EEPROM Read | |
UncorrPulseOutputProve | VT_UI2 | 'r' EEPROM Read | |
UncorrResidual | VT_I4 | 'l' Live Data | Uncorrected Residual |
UncorrtVolume | VT_I4 | 'l' Live Data | Uncorrected Volume |
UncorrVolMultiplier | VT_UI1 | 'r' EEPROM Read | |
UncorrVolMultProve | VT_UI1 | 'r' EEPROM Read | |
VolFaultOccurred | VT_BOOL | 'l' Live Data | Volume Fault Occurred |
VolFaultPresent | VT_BOOL | 'l' Live Data | Volume Fault Present |
VolumeUnits | VT_UI1 | 'r' EEPROM Read | Volume Units |
Related content
Weatherford 8500 OPC Items
Weatherford 8500 OPC Items
More like this
Reynolds LVC OPC Items
Reynolds LVC OPC Items
More like this
Flow Automation OPC Items
Flow Automation OPC Items
More like this
SCANCOM OPC Items
SCANCOM OPC Items
More like this
Dresser
Dresser
More like this
Modbus ETNG OPC Items
Modbus ETNG OPC Items
More like this
For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.