Reynolds LVC OPC Items

Reynolds LVC OPC Items

Standard Items

See Device Standard Items.

Protocol Items

The Reynolds LVC protocol implementation supports register numbers as item names. To access a register, client applications specify the register number that is within one of the register ranges in the selected register set for the device.

Item

Data Type

Description

Item

Data Type

Description

BasePressure

R4

Base Pressure.

BaseTemperature

R4

Base Temperature in Deg F.

CallReportContractDay

BOOL

Exception call reporting contract day.

CalibrationInProgress

BOOL

Calibration in progress.

CallReportContractMonth

BOOL

Exception call reporting contract month.

CallReportHighPressure

BOOL

Exception call reporting high pressure.

CallReportHighTemperature

BOOL

Exception call reporting high temperature.

CallReportLowBattery

BOOL

Exception call reporting low battery.

CallReportLowTemperature

BOOL

Exception call reporting low temperature.

CallReportMonthWarning

BOOL

Exception call reporting month warning.

CaseTemperature

R4

Case temperature, Deg F.

ClockwiseIndexRotation

BOOL

Decode clock wise index rotation.

ContractDailySCF

R8

Contract day accumulated SCF in units of cvsf.

ContractDay

I2

Contract Day.

ContractDayAlarmActive

BOOL

High contract day alarm active.

ContractDayAlarmEnable

BOOL

Enable high contract day alarm.

ContractHour

I2

Contract Hour

ContractHourlySCF

R8

Contract hourly accumulated SCF in units of cvsf.

ContractMonthAlarmActive

BOOL

High contract month alarm active.

ContractMonthAlarmEnable

BOOL

Enable high contract month alarm.

ContractMonthlySCF

R8

Contract month accumulated SCF in units of cvsf.

ContractMonthWarningActive

BOOL

Warning contract month alarm active.

ContractMonthWarningEnable

BOOL

Enable warning contract month alarm.

CorrectedOutputFactor

R4

Corrected volume pulse output scale factor.

CorrectedVolAccumulator

R8

Corrected Volume accumulator.

CorrectedVolRemainder

R4

Correct volume remainder.

CorrectedVolumeFactor

R4

Float, Corrected volume display scale factor.

CorrectionFactor

R4

Correction factor.

CurrentMonthCorrectedVol

R8

Current month corrected volume.

CurrentMonthUncorrectedVol

R8

Current month uncorrected volume.

DoorAjar

BOOL

Door ajar.

DoorAlarm

BOOL

Door alarm.

EnableCallubration

BOOL

Enable Calibration.

EnableFastIndexing

BOOL

Enable fast index sampling.

EnableHighPressureAlarm

BOOL

Enable Alarm 1, High pressure.

EnableHighTemperatureAlarm

BOOL

Enable Alarm 3, High temp.

EnableLowBatteryAlarm

BOOL

Enable Alarm 5, Low battery.

EnableLowPressureAlarm

BOOL

Enable Alarm 2, Low pressure.

EnableLowTemperatureAlarm

BOOL

Enable Alarm 4, Low temp.

ExternalPower

R4

External power.

FirmwareModel

R8

Firmware Model.

FixedFpv

R4

Fixed FPV.

FixedPressure

R4

Fixed Pressure.

FixedTemperature

R4

Fixed Temperature.

FpvSquaredFactor

R4

Fpv squared factor.

GasPressure

R4

Gas Pressure.

GasTemperature

R4

Gas Temperature.

HighPressureAlarmActive

BOOL

High pressure alarm active.

HighPressureAlarmLimit

R4

Alarm limit, high pressure

HighTemperatureAlarmActive

BOOL

High temp alarm active.

HighTemperatureAlarmLimit

R4

Alarm limit, high temperature

InputScaleFactor

R4

Input scale factor

LcdPreviousMonthEnable

BOOL

Enable previous month accumulators on LCD

LowBatteryAlarmActive

BOOL

Low battery alarm active.

LowBatteryAlarmLimit

R4

Alarm limit, low battery voltage

LowPressureAlarmActive

BOOL

Low pressure alarm active.

LowPressureAlarmLimit

R4

Alarm limit, low pressure

LowTemperateAlarmActive

BOOL

Low temp alarm active.

LowTemperatureAlarmLimit

R4

Alarm limit, low temperature

MaximumDailyFlow

R8

Maximum daily flow.

MaximumHourlyFlow

R8

Maximum hourly flow.

MeterKFactor

R4

Meter calibration adjustment  factor

MeterNumber

R8

Meter Number.

MinimumDailyFlow

R8

Minimum daily flow.

MinimumHourlyFlow

R8

Minimum hourly flow.

PercentCO2

R4

Percent Cardbon Dioxide.

PercentNirtogen

R4

Percent Nitrogen.

PressureDecimals

BOOL

Pressure decimals, 0 = 2, 1 = 1.

PressureFactor

R4

Pressure factor

PreviousMaxDailyFlow

R8

Previous maximum daily flow.

PreviousMaxHourlyFlow

R8

Previous maximum hourly flow.

PreviousMinDailyFlow

R8

Previous minimum daily flow.

PreviousMinHourlyFlow

R8

Previous minimum hourly flow.

PreviousMonthCorrectedVol

R8

Previous month corrected volume.

PreviousMonthUncorrectedVol

R8

Previous month uncorrected volume.

PulseOutEnable

BOOL

Pulse out enable

RtcDay

I2

Real-time clock Day

RtcHour

I2

Real-time clock Hour

RtcMinute

I2

Real-time clock Minute

RtcMonth

I2

Real-time clock Month

RtcSecond

I2

Real-time clock Second

RtcYear

I2

Real-time clock Year

SandiaUnitId

I2

Sandia Unit id

SerialNumber

R8

Serial Number

SiteAddress1

String

Site Address 1

SiteAddress2

String

Site Address 2

SiteAddress3

String

Site Address 3

SpecificGravity

R4

Specific Gravity

TemperatureFactor

R4

Temperature factor

TimeZoneString

String

Time zone

TurbineDivisor

I2

Turbine interface vivisor

TurbineKFactor

R8

Turbine K factor

TurbineMeterUsed

BOOL

Turbine meter used

UncorrectedOutputFactor

R4

Uncorrected volume pulse output count.

UncorrectedVolAccumulator

R8

Uncorrected Volume accumulator.

UncorrectedVolRemainder

R4

Uncorrect volume remainder

UncorrectedVolumeFactor

R4

Uncorrect vol display scal factor

UseContinuousWakeup

BOOL