Modbus OMNI Commands
Common Commands
See Device Object Common Commands for commands that are common to all device types.
Commands
Command | Description | Parameters |
---|---|---|
Test Communication | When executed, ACM will poll a known OPC item from the device and wait for the response to see if the communication is good. | None |
Retrieve History | Requests the retrieval of history records (for all enabled meters). | None |
Retrieve meter config during next history poll | Retrieves meter configuration data during the next history retrieval | None |
Reset Archive | Clears the archive retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Archive Number |
Move Archive | Moves the saved archive retrieval position to an older record. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of records to move back. | Archive Number Record Count |
Skip Archive | Moves the saved daily retrieval position forward. Provide the record count in parameter one, or leave blank for all meters. Enter the number of records to skip. | Archive Number Reset Archive |
Time Sync | Causes a comparison of the date and time in the device to the host date and time. Once compared, the configured rules of the selected time sync object will be applied - including time zone and daylight saving options. | None |
Request Batch Report | Request one of the available batch text reports. Enter the report number (1 = most recent; 8 = oldest) or leave blank for the most recent report. | Report Number |
Request Prove Report | Request one of the available prove reports. Enter the report number (1 = most recent; 8 = oldest) or leave blank for the most recent report. | Report Number |
Request Daily Report | Request one of the available daily text reports. Enter the report number (1 = most recent; 8 = oldest) or leave blank for the most recent report. | Report Number |
Request Snapshot Report | Request the snapshot report. | None |
Request Miscellaneous Report | Request the miscellaneous report. | None |
Request Template Report | Request one of the available template reports. Enter the value for the desired template (1=Snapshot; 2=Batch; 3=Daily; 4=Prove). | Report Number |
Request Ethernet Configuration Report | Request one of the available Ethernet configuration reports. Enter the value for the desired report (1 - 3). | Report Number |
Read Custom Packet Configuration | Re-read the custom packet configuration from the OMNI. | None |
Read Archive Configuration | Re-read the archive configuration from the OMNI. Use this command to make ACM read the configuration of one or more OMNI archives. Note that this command is sent automatically if ACM detects that the data size of an archive record does not match the size reported in a previous archive configuration read. | None |
Reset Report | Reset the positions for auto-report collection. | None |
Read Product Information | Re-read the product names and data from the OMNI. | None |
Document Periodic Register | Write the internal register map used for periodic records to the server machine file "C:\ProgramData\AutoSol\CommunicationManager\7\asiMODBUS_OMNI_PERIODIC_REGISTER_DOC.txt" | None |
Document Batch Register | Write the internal register map used for batch records to the server machine file "C:\ProgramData\AutoSol\CommunicationManager\7\asiMODBUS_OMNI_BATCH_REGISTER_DOC.txt" | None |
Document Prove Register | Write the internal register map used for prove records to the server machine file "C:\ProgramData\AutoSol\CommunicationManager\7\asiMODBUS_OMNI_PROVE_REGISTER_DOC.txt" | None |
For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.