Totalflow Commands

Common Commands

See Device Object Common Commands for commands that are common to all device types.

Commands

CommandDescriptionParameters

Test Communication

ACM will poll a known OPC item from the device and wait for the response to see if the communication is good.None
Retrieve HistoryRequests the retrieval of history records (for all enabled meters).None
Retrieve TrendRequests the retrieval of trend records (for all enabled trends).None
Retrieve Log PeriodRequests the retrieval of log period records (for all enabled meters).None
Retrieve DailyRequests the retrieval of daily records (for all enabled meters).None
Retrieve EventRequests the retrieval of event records (for all enabled meters).None
Adhoc Log Period RetrievalRequests the retrieval of log period records for all enabled meters without changing the history position information.None
Adhoc Daily RetrievalRequests the retrieval of daily records for all enabled meters without changing the history position information.None
Adhoc Event RetrievalRequests the retrieval of event records for all enabled meters without changing the history position information.None
Retrieve meter config during next history pollRetrieves meter configuration data for all meters during the next history retrieval.Meter Number
Reset History (LogPeriod/Daily/Event) PointerClears the history (LogPeriod/Daily/Event) retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters.Meter Number
Reset Log Period PointerClears the Log Period retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters.Meter Number
Reset Daily PointerClears the Daily retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters.Meter Number
Reset Event PointerClears the Event retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters.Meter Number
Reset Trend PointerClears the trend retrieval position so retrieval starts at the oldest record. Provide the trend number.Trend Number
Set Log Period PointerSets the log period history retrieval position to a specified date and time. Provide the meter number in parameter one, or leave blank for all meters. Provide the record position date/time for parameter two.

Meter Number

Record Position Date/Time

Set Daily PointerSets the daily history retrieval position to a specified date and time. Provide the meter number in parameter one, or leave blank for all meters. Provide the record position date/time for parameter two.

Meter Number

Record Position Date/Time

Set Trend PointerSets the trend history retrieval position to a specified date and time. Provide the trend number in parameter one, or leave blank for all trends. Provide the record position date/time for parameter two.

Trend Number

Record Position Date/Time

Move EventMoves the saved history retrieval position backwards to an older number. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of records to move.

Meter Number

Record Count

Skip Event RecordsMoves the saved history retrieval position forward. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of records to move.

Meter Number

Record Count

Time Sync Causes a comparison of the date and time in the device to the host date and time. Once compared, the configured rules of the selected time sync object will be applied - including time zone and daylight saving options.None
Re-load Extra Data FileRe-loads the external ABB file containing extra data field descriptions.None

For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.