TGP OPC Items
TGP OPC Items
Standard Items
Protocol Items
F.S.T.B (WO)[M]
- F specifies the desired function code.
- For TGP Standard devices the function code is between 0 and 1023.
- For TGP SBC60 devices the function code is between 0 and 511.
- S specifies the desired sub function code.
- For TGP Standard Devices the sub function code is between 0 and 65535.
- For TGP SBC60 devices the sub function code is between 0 and 255.
- The default sub function code is 0.
- T specifies the item type index.
- An item type index of 0 represents data quality.
- An item type index of 1 represents a floating point data type.
- An item type index of 2 represents a long data type.
- An item type index of 5 represents a date string in the following format: YY/MM/DD, where YY represents the year, MM represents the month, and DD represents the day.
- An item type index of 6 represents a time string in the following format: HH:MM:SS, where HH represents the hour, MM represents the minute, and SS represents the second.
- An item type index of 8 represents a status data type.
- The default item type index is 1
- B specifies the bit designator (for use with item index type 8 only).
- The B bit designator is a value between 0 and 31.
- Writes for item index type 8 must be performed as a DWORD.
- The default bit designator is 32 (DWORD).
- If an item name has a (WO) to the right of the item name definition then the item will be a “Write Only” item. A “Write Only” item will not be polled from the field device.
- If an item name has a [M] to the far right of the item name definition then the item will be flagged as a “Multi-function Code Write” item. When a “Multi-function Code Write” item is written to by the OPC Client, the TGP Protocol component will generate a write message to the item function code and a write message to the next consecutive function code. The sub function code and value of the subsequent function code will be identical to the first item. The “Multi- function Code Write” is not supported for item type index 8.
- If an item name has a [RO] to the right of the item name definition, then the item will be Read Only.
Item Syntax Patterns
Item.Type.Index[M]
Item.Type.Index[WO]
Item.Type.Index[RO]
Related content
BenchMark OPC Items
BenchMark OPC Items
More like this
Romet OPC Items
Romet OPC Items
More like this
Weatherford 8500 OPC Items
Weatherford 8500 OPC Items
More like this
BSAP OPC Items
BSAP OPC Items
More like this
SCANCOM OPC Items
SCANCOM OPC Items
More like this
Teledyne CA OPC Items
Teledyne CA OPC Items
More like this
For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.