Modbus ETNG OPC Items
Standard Items
Protocol Items
Measurement Items
The Modbus ETNG protocol module does not support item conversion from one data type to another. All items use their native data types.
Item | Data Type | Description |
---|---|---|
ACCUMMCF | R4 | Accum. Volume (MCF) |
BATTVOLTS | R4 | Current battery voltage |
CURRENTAP | R4 | Current AP |
CURRENTDP | R4 | Current DP |
CURRENTMCF | R4 | Current flow rate (MDF/Day) |
CURRENTTF | R4 | Current Temp |
LASTALARMS | UI4 | Last Calculation Period Alarms |
LASTAP | R4 | Last Calculation Period abs. pressure |
LASTAR | R4 | Last Calculation Period Argon |
LASTBTU | R4 | Last Calculation Period BTU |
LASTCD | R4 | Last Calculation Period Cd. Specific to AGA31992 |
LASTCO | R4 | Last Calculation Period Carbon Mon |
LASTCO2 | R4 | Last Calculation Period CO2 |
LASTCOUNTS | UI4 | Last Calculation Period Int. counts |
LASTDP | R4 | Last Calculation Period diff. pressure |
LASTETHANE | R4 | Last Calculation Period Ethane |
LASTEV | R4 | Last Calculation Period Ev. Specific to AGA31992 |
LASTEXT | R4 | Last Calculation Period Extension. |
LASTFA | R4 | Last Calculation Period F(a). Specific to AGA31985 |
LASTFAUX | R4 | Last Calculation Period F(aux) |
LASTFB | R4 | Last Calculation Period F(b). Specific to AGA31985 |
LASTFG | R4 | Last Calculation Period F(g). Specific to AGA31985 |
LASTFIP | R4 | Last Calculation Period FIP. Specific to AGA31992 |
LASTFPB | R4 | Last Calculation Period F(pb). Specific to AGA31985 |
LASTFPV | R4 | Last Calculation Period F(pv) |
LASTFR | R4 | Last Calculation Period F(r). Specific to AGA31985 |
LASTFTB | R4 | Last Calculation Period F(tb). Specific to AGA31985 |
LASTFTF | R4 | Last Calculation Period F(tf). Specific to AGA31985 |
LASTFW | R4 | Last Calculation Period F(w) |
LASTGRAVITY | R4 | Last Calculation Period Gravity |
LASTH | R4 | Last Calculation Period Hydrogen |
LASTH2O | R4 | Last Calculation Period H2O |
LASTH2S | R4 | Last Calculation Period H2S |
LASTHE | R4 | Last Calculation Period Helium |
LASTIBUTANE | R4 | Last Calculation Period IButane |
LASTIPENTANE | R4 | Last Calculation Period IPentane |
LASTMCF | R4 | Last Calculation Period volume (MCF) |
LASTMETHANE | R4 | Last Calculation Period Methane |
LASTN2 | R4 | Last Calculation Period N2 |
LASTNBUTANE | R4 | Last Calculation Period NButane |
LASTNDECANE | R4 | Last Calculation Period NDecane |
LASTNHEPTANE | R4 | Last Calculation Period Nheptane |
LASTNHEXANE | R4 | Last Calculation Period NHexane |
LASTNNONANE | R4 | Last Calculation Period Nnonane |
LASTNOCTANE | R4 | Last Calculation Period NOctane |
LASTNPENTANE | R4 | Last Calculation Period NPentane |
LASTO2 | R4 | Last Calculation Period Oxygen |
LASTPROPANE | R4 | Last Calculation Period Propane |
LASTQM | R4 | Last Calculation Period qm. Specific to AGA31992 |
LASTQV | R4 | Last Calculation Period Qv |
LASTRANGE | UI4 | Last Calculation Period Int. range 4 |
LASTRHOB | R4 | Last Calculation Period Rhob. Specific to AGA31992 |
LASTTF | R4 | Last Calculation Period flowing temp |
LASTY | R4 | Last Calculation Period Y |
YESTMCF | R4 | Yesterday's volume (MCF) |
Measurement – Pulse Input – AGA 7 Items
Item | Data Type | Description |
---|---|---|
PICURRENTPIC | R4 | Current Pulse Input Count. Specific to AGA7 |
PIYESTUVOL | R4 | Yesterday's uncorrected volume. Specific to AGA7 |
PIYESTLOACF | R4 | Yesterday's LO ACF. Specific to AGA7 |
PIYESTHIACF | R4 | Yesterday's HI ACF. Specific to AGA7 |
PIACCUMUVOL | R4 | Accumulated uncorrected volume. Specific to AGA7 |
UPLOADHISTORY | I2 | This item is used to perform an upload of the log period, event, daily and alarm in the device. Set this item to –1 to upload any records that have been logged since the last upload. Set this item to a positive number to upload a number of days' worth of records. The item value will be reset to zero upon completion of a successful upload, or to three if the upload failed. |
AUTOHISTORY | I2 | This item is used to perform an auto upload of the log period, event, daily and alarm in the device. The item value will be reset to zero upon completion of a successful upload, or to three if the upload failed. |
AUTO_SYNCTIME | I4 | This item is used to synch the time in the RTU. Set this item to 1 will trigger the synch or the action will be taken on every interval. The item value will be reset to zero, after a successful upload. |
AUTOTREND | I2 | AutoTrend/TrendNumberis used to retrieve trend data from the device. "/TrendNumber" is 0 based where 0 is the first trend, 1 is the second trend and so on. Trend output is data file only, no Electronic Flow Measurement (EFM) output. The value will return to zero if successful, and three if failed. |
AUTOTRENDNAME | I2 | AutoTrend/TrendNameis used to retrieve trend data from the device."/TrendName" is case sensitive and should match the trend name set up in the device. Trend output is data file only, no EFM output. The value will return to zero if successful, and three if failed. |
Device Setup
Item | Data Type | Description |
---|---|---|
PWDENABLED | UI1 | Password mode enabled |
SECCHECK | UI1 | Check security code? |
ELEMENT | UI1 | Primary element |
CALCMETH | UI1 | FCU volume calc. method |
RPTUNITS | UI1 | FCU report units |
CALCUNITS | UI1 | FCU calculation units |
FPVMETH | UI1 | Supercomp method |
VOLLOGPRD | UI4 | Volume Log period |
VOLCALCPRD | UI2 | Volume calculation period |
CONTRACTHOUR | UI1 | Contract Hour |
ORD | R4 | Orifice diameter |
MONELOR | UI1 | Monel orifice? |
PIPED | R4 | Pipe diameter |
TAPLOC | UI1 | Tap Location |
TEMPBASE | R4 | Temperature base |
PRESSBASE | R4 | Pressure base |
RATIO | R4 | Ratio of specific heats |
VISCOSITY | R4 | Viscosity |
ZEROCUTOFF | R4 | Zero cutoff |
FT | R4 | F(f) |
FP | R4 | F(p) |
BAROPRESS | R4 | Barometric pressure |
FIXEDFAUX | R4 | Fixed F(aux) |
USESQRTAVG | UI1 | Use square root AP, DP avgs |
USEY | UI1 | Use Y |
USEFPV | UI1 | Use F(pv) |
USEFW | UI1 | Use F(w) |
USEFAUX | UI1 | Use F(aux) |
APLOWLIMIT | R4 | AP lo limit |
APHIGHLIMIT | R4 | AP hi limit |
APLOWCAL | R4 | AP low calibration |
APMIDLOWCAL | R4 | AP mid low calibration |
APMIDHIGHCAL | R4 | AP mid high calibration |
APHIGHCAL | R4 | AP high cal |
DPLOWLIMIT | R4 | DP low limit |
DPHIGHLIMIT | UI1 | DP hi limit |
DPLOWCAL | R4 | DP lo calibration |
DPMIDLOWCAL | R4 | DP mid low calibration |
DPMIDHIGHCAL | R4 | DP mid high calibration |
DPHIGHCAL | R4 | DP high calibration |
RTD | UI1 | RTD installed |
USEMEASTEMP | UI1 | Use measured temperature |
FIXEDTEMP | R4 | Fixed temperature |
TEMPBIAS | R4 | Temperature bias |
TFLOWLIMIT | R4 | Tf low limit |
TFHIGHLIMIT | R4 | Tf high limit |
FLOWLOWLIMIT | R4 | Flow Rate low limit (MCF/Day) |
FLOWHIGHLIMIT | R4 | Flow Rate high limit (MCF/Day) |
TRIP1LC | UI1 | Trip contact on LC alarm |
TRIP1DPLOW | UI1 | Trip contact on DP low alarm |
TRIP1DPHIGH | UI1 | Trip contact on DP high alarm |
TRIP1APLOW | UI1 | Trip contact on AP low alarm |
TRIP1APHIGH | UI1 | Trip contact on AP high alarm |
TRIP1REMOTE | UI1 | Trip contact on Remote |
TRIP1SETPT | UI1 | Trip contact on volume set point |
VOL1SETPT | R4 | Volume Set Point for contact |
TRIP1RESET | UI1 | Auto reset contact |
LIVESTREAM | UI1 | Attach to stream |
STREAMID | UI4 | Stream ID |
USEFIXEDERROR | UI1 | Use Fixed Analysis on error |
FIRSTRECEIVED | UI1 | First analysis received |
FIXEDBTU | R4 | Fixed Analysis BTU |
FIXEDGRAVITY | R4 | Fixed Analysis Gravity |
FIXEDN2 | R4 | Fixed Analysis N2 |
FIXEDCO2 | R4 | Fixed Analysis CO2 |
FIXEDH2S | R4 | Fixed Analysis H2S |
FIXEDH2O | R4 | Fixed Analysis H2O |
FIXEDHE | R4 | Fixed Analysis HE |
FIXEDMETHANE | R4 | Fixed Analysis Methane |
FIXEDETHANE | R4 | Fixed Analysis Ethane |
FIXEDPROPANE | R4 | Fixed Analysis Propane |
FIXEDNBUTANE | R4 | Fixed Analysis NButane |
FIXEDIBUTANE | R4 | Fixed Analysis IButane |
FIXEDNPENTANE | R4 | Fixed Analysis NPentane |
FIXEDIPENTANE | R4 | Fixed Analysis IPentane |
FIXEDNHEXANE | R4 | Fixed Analysis NHexane |
FIXEDNHEPTANE | R4 | Fixed Analysis NHeptane |
FIXEDNOCTANE | R4 | Fixed Analysis NOctane |
FIXEDNNONANE | R4 | Fixed Analysis NNonane |
FIXEDNDECANE | R4 | Fixed Analysis NDecane |
FIXEDO2 | R4 | Fixed Analysis Oxygen |
FIXEDCO | R4 | Fixed Analysis Carbon Monoxide |
FIXEDH | R4 | Fixed Analysis Hydrogen |
FIXEDAR | R4 | Fixed Analysis Argon |
TRIP1TFLOW | UI1 | Trip contact on Tf low |
TRIP1TFHIGH | UI1 | Trip contact on Tf high |
TRIP1TFLOWLOW | UI1 | Trip contact on FlowRate low |
TRIP1TFLOWHIGH | UI1 | Trip contact on FlowRate high |
TRIP2LC | UI1 | Trip DO2 on LC alarm |
TRIP2DPLOW | UI1 | Trip DO2 on DP low alarm |
TRIP2DPHIGH | UI1 | Trip DO 2 on DP high alarm |
TRIP2APLOW | UI1 | Trip DO 2 on AP low alarm |
TRIP2APHIGH | UI1 | Trip DO 2 on AP high alarm |
TRIP2REMOTE | UI1 | Trip DO 2 on Remote Sense |
TRIP2SETPT | UI1 | Trip DO 2 on volume set point |
VOL2SETPT | R4 | Volume Set Point for DO 2 |
TRIP2RESET | UI1 | Auto reset DO 2 |
TRIP2TFLOW | UI1 | Trip DO 2 on Tf low |
TRIP2TFHIGH | UI1 | Trip DO 2 on Tf high |
TRIP2FLOWLOW | UI1 | Trip DO 2 on FlowRate low |
TRIP2FLOWHIGH | UI1 | Trip DO 2 on FlowRate high |
SUPPORTPIPE | UI1 | Support Pipe Taps? |
TAPPIPE | UI1 | Tap type |
FIXEDFB | R4 | Fixed F(b) |
USEFB | UI1 | Use F(b) |
USEFR | UI1 | Use F(r) |
USEFPB | UI1 | USE F(pb) |
USEFTB | UI1 | Use F(tb) |
USEFTF | UI1 | Use F(tf) |
USEFG | UI1 | Use F(g) |
USEFA | UI1 | Use F(a) |
ORIFRETEMP | R4 | Orifice reference temp |
PIPEREFTEMP | R4 | Pipe reference temp |
ZB | R4 | Zb |
ORIFCOEF | R4 | Orifice plate coef. Of expansion |
PIPECOEF | R4 | Pipe coef. of expansion |
FIXEDCD | R4 | Fixed Cd |
USECALCCD | UI1 | Use calced Cd? |
APMIDCAL | R4 | AP Mid High Calibration |
DPMIDCAL | DP mid calibration | |
FIXEDAP | R4 | Fixed AP |
UFLOWLOWLIMIT | R4 | Uncorrected Flow Rate Low Limit |
UFLOWHIGHLIMIT | R4 | Uncorrected Flow Rate High Limit |
TRIP1ACFLOW | UI1 | Trip Contact on ACF low alarm |
TRIP1ACFHIGH | UI1 | Trip Contact on ACF high alarm |