Weatherford 8500 Configuration

See the Common Device Configuration guide for assistance configuring the General, Options, Details, and Logging tabs. See the Connection/Schedule page for assistance with the Connection tab.

Device Tab

Address

The slave address of the controller.

Device Type

Select the field device type for this object.

  • WellPilot RPOC - default

  • ePic VSD

  • ePic RPC

  • EXS-1000

  • M2000

  • M8800

  • M8750

  • M8500/8650

Max Parameters

The maximum number of parameters to request in one poll read message. This property allows the size of the response message to be adjusted.

  • Range - 1 to 100

  • Default - 40

Protocol Options

Enable Enhanced Logging Mode

  • Default = Not Selected. This prints very verbose messages in the ACM log about the current state of the protocol engine and/or card upload.

Always use FC16 for card upload

  • Default = Not Selected. This enables the user to change the Function Code (FC) used to upload card buffer data from the default used for a particular controller type. If the controller supports FC25, this option will cause the driver to use FC16EX instead. If the controller supports FC16EX, this option will cause the driver to use FC16 instead.

Time Sync Tab

Enable Time Synchronization

Default = Not selected. Select this to configure and allow requests to be made. 

Time Synchronization Configuration

Click {…}  to select or create the Connection Object assigned to this device. See the Time Synchronization section for more details.

Time Synchronization Interval

Select the desired Time Synchronization Interval relating to the Schedule object assigned on the Connection tab. Time Synchronization checks occur on the frequency of this interval.

Time Synchronization Priority

  • Low. Queues up with other Low priority items.

  • Medium (Default). Interrupts Low priority items, and queues up with other Medium priority items.

  • High. Interrupts Medium and Low priority items, and queues up with other High priority items.

Timezone

Default = UTC-06:00 Central Time (US & Canada).

Card Collection Tab

Collection Priority

  • Low (Default). Queues up with other Low priority items.

  • Medium. Interrupts Low priority items, and queues up with other Medium priority items.

  • High. Interrupts Medium and Low priority items, and queues up with other High priority items.

Card Collection Interval

Select the automatic collection Interval relating to the Schedule object assigned on the Connection tab.

Card Meter

Click {…} to select or create the Meter Object assigned to this device object.  See the Meter section for more details.

In order to publish data to the ACM database, a device object must have an associated meter object. Each device object should have a unique meter object. If card data is to be published to the database, assign a meter object to this property.

If card data is not to be published to the database, but only returned in the associated card data OPC items, this property may be left as {Unassigned}.

Card Collection

Select the type of card buffers to upload.

Buffer Type

Description

Buffer Type

Description

Event

Collect the Event buffer. Only applies to controllers that support either function codes FC16EX or FC24. If enabled, event types in the Event Collection group must also be selected.

Pump On

Collect the Pump On buffer.

Shutdown

Collect the Shutdown (Pump Off) buffer.

Present

Collect the Present (Live) buffer.

Downhole

Collect downhole cards in addition to the surface cards. This option is in conjunction with the other buffer type selections: Event, Pump On, Shutdown, and Present. Only applies to the WellPilot RPOC.

Event Collection

Select the type of events to upload. These options only apply if the Card Collection type of Event is enabled.

Event Type

Description

Event Type

Description

Fault

Collect fault events and associated card data.

Alarms

Collect alarm events and associated card data.

Plain

Collect plain events and associated card data.

Number of Strokes in Set

Enter the number of strokes to upload per card set. Range 0 to 5, with zero signifying to use the maximum allowed.

Max Card Points per Message

Enter the maximum number of card points to return in each response message. This property allows the size of the response message to be adjusted. Range 0 to 280, with zero signifying to use the maximum allowed.

Some controllers allow more than 280 points per message. Enter a zero for this property to allow the controller maximum to be used if desired.

FC16 Card Upload Option

These properties only apply if the controller uses FC16 or FC16EX for card buffer upload. The properties determine the data returned in the card.

Load Type

  • Pounds - actual pounds of load

  • Fractional - fractional pump/off boxed value

Fractional Load Precision

Only applies if Fractional is selected for Load Type

  • Two Digit - two digit precision

  • Three Digit - three digit precision

Position Type

  • Fractional - actual fractional position values

  • Marking - marking of well cycle tops or bottoms. This option generates marking indexes and load values only, no position values.

  • Synthesized - synthesized position values

  • Voltage - voltage position values

Fractional Position Precision

Only applies if Fractional or Synthesized is selected for Position Type

  • Two Digit - two digit precision

  • Three Digit - three digit precision

Marking Type

Only applies if Marking is selected for Position Type

  • Top - mark the top of stroke

  • Bottom - mark the bottom of stroke

For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.