/
Database Create Script Column Syntax Reference
Database Create Script Column Syntax Reference
Overview
Below is a list of the column syntax used for each data type in the supported script generators.
Microsoft SQL Server | |
boolean/bit | [column_name][bit] NULL |
character | [column_name][tinyint] NULL |
unsigned character | [column_name][smallint] NULL |
short integer | [column_name][smallint] NULL |
unsigned short integer | [column_name][int] NULL |
long integer | [column_name][real] NULL |
unsigned long integer | [column_name][float] NULL |
single-precision float | [column_name][float] NULL |
double-precision float | [column_name][float] NULL |
string/text | [column_name][nvarchar](max_length) NULL |
date | [column_name][datetime] NULL |
Microsoft Access | |
boolean/bit | [column_name][YESNO] NULL |
character | [column_name][SMALLINT] NULL |
unsigned character | [column_name][SMALLINT] NULL |
short integer | [column_name][SMALLINT] NULL |
unsigned short integer | [column_name][INTEGER] NULL |
long integer | [column_name][INTEGER] NULL |
unsigned long integer | [column_name][FLOAT] NULL |
single-precision float | [column_name][REAL] NULL |
double-precision float | [column_name][FLOAT] NULL |
string/text | [column_name][TEXT](max_length) NULL |
date | [column_name][DATETIME] NULL |
Oracle | |
boolean/bit | column_name NUMBER(1) NULL |
character | column_name NUMBER(5) NULL |
unsigned character | column_name NUMBER(5) NULL |
short integer | column_name NUMBER(5) NULL |
unsigned short integer | column_name NUMBER(11) NULL |
long integer | column_name NUMBER(11) NULL |
unsigned long integer | column_name BINARY_DOUBLE NULL |
single-precision float | column_name BINARY_FLOAT NULL |
double-precision float | column_name BINARY_DOUBLE NULL |
string/text | column_name VARCHAR2(max_length) NULL |
date | column_name DATE NULL |
MySQL | |
boolean/bit | [column_name] BOOL NULL |
character | [column_name] TINYINT NULL |
unsigned character | [column_name] SMALLINT NULL |
short integer | [column_name] SMALLINT NULL |
unsigned short integer | [column_name] INT NULL |
long integer | [column_name] INT NULL |
unsigned long integer | [column_name] DOUBLE NULL |
single-precision float | [column_name] FLOAT NULL |
double-precision float | [column_name] DOUBLE NULL |
string/text | [column_name] VARCHAR(max_length) NULL |
date | [column_name] DATETIME NULL |
Sybase | |
boolean/bit | [column_name] BIT NULL |
character | [column_name] TINYINT NULL |
unsigned character | [column_name] SMALLINT NULL |
short integer | [column_name] SMALLINT NULL |
unsigned short integer | [column_name] INTEGER NULL |
long integer | [column_name] INTEGER NULL |
unsigned long integer | [column_name] DOUBLE NULL |
single-precision float | [column_name] REAL NULL |
double-precision float | [column_name] DOUBLE NULL |
string/text | [column_name] VARCHAR(max_length) NULL |
date | [column_name] DATETIME NULL |
, multiple selections available,
Related content
Database
Database
Read with this
SCANCOM Data Types
SCANCOM Data Types
More like this
Modbus Enron Data Types
Modbus Enron Data Types
More like this
Modbus SCADAPack Data Types
Modbus SCADAPack Data Types
More like this
Daniels RTU/ASCII Default Registers
Daniels RTU/ASCII Default Registers
More like this
Weatherford 8500 OPC Items
Weatherford 8500 OPC Items
More like this
For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.