Eagle Configuration

Eagle Configuration

 

See the Common Device Configuration guide for assistance configuring the General, Options, Details, and Logging tabs.  See the Connection/Schedule page for assistance with the Connection tab.

Device Tab

image-20250214-124930.png

HostID

  • Default = 0. Device Host ID.

SiteID

  • Default = 0. Device Site ID.

ModbusHexAscii Enabled

  • Default = Not selected. Communicate to the ModbusHexAscii enabled Eagle device with the Eagle Hex Ascii protocol.

First Modbus Process

  • Default = 0. This valid process number is used to switch the device back to the ModbusHexAscii protocol at the end of the poll cycle when communicating via the the Eagle Hex Ascii protocol.  If 0 or no process number is provided, the device might switch it back automatically if configured in the device hardware configuration.

Use V2 Hex ASCII header

  • Default = Not selected. 

Retrieve history during call-in

  • Default = Not selected. This will automatically retrieve all enabled histories on receiving an unsolicited message.

ContractDay

  • Default = Empty. Device Contract Day.

ContractHour

  • Default = Empty. Device Contract Hour.

Security Enabled

  • Default = Not selected. Communicate to the User Access Control (UAC) enabled Eagle device with the credentials provided.

Username

  • Default = Empty. Username in the RTU’s User Access Control (UAC) configuration.

Password

  • Default = Empty. Password in the RTU’s User Access Control (UAC) configuration.

Time Sync Tab

See the Common Time Sync Tab page.

Archive Collection Tab

Collection Priority

  • Low (Default)Queues up with other Low priority items.

  • Medium. Interrupts Low priority items, and queues up with other Medium priority items.

  • High. Interrupts Medium and Low priority items, and queues up with other High priority items.

Extended History/Meter Config/Audit Trail Interval

  • Default = Interval 15. Select the desired Interval relating to the Schedule object assigned on the Connection tab. Retrievals occur on the frequency of this interval.

Audit Trail Enable

  • Default = Not selected. Select to configure collection.

Audit Trail Map

Audit Trail Archive

  • Click  to select or create an Archive Limits. See the Archive Limits section for more details.

Audit Trail Reset

  • Default = Not selected. When selected, will reset the audit trail record. After reset, the audit trail records will not be deleted, it will only be marked in the RTU to be overwritten.

Alarm Processes

  • List all device alarm processes for each meter separated by a comma with no space (i.e. Device1,Device2,Device3).

Meter Runs Tab

Meter Runs - Meter

  • Meter 1-6. Select the meter run to configure.

Meter

  • Meter Object assigned to this meter run number. Click  to select or create one. See the Meter section for more details.

Note

For Meter Rule Mapping, see Eagle Advanced Meter Configuration

Collect Meter Extended History

  • Default = Not selected. Select to configure collection.

Extended History Archive

Extended History GC IO

  • Click  to select or create the Gas Chromatograph assigned to the selected meter run. See the Gas Chromatograph section for more details.

History Processes

  • The device history collection processes lists all processes for each meter. For more than one process, separate each one with a colon without a space (i.e. 23:24:25)

Max Records Collect Enable

  • Default = Not selected. Select to set the maximum records per interval for the Extended History Collect. Default = 50. 

 

Related content

Eagle
More like this
Eagle OPC Items
Eagle OPC Items
More like this
Eagle Advanced Meter Configuration
Eagle Advanced Meter Configuration
Read with this
Modbus
More like this
Protocols
Read with this
BenchMark Configuration
BenchMark Configuration
More like this

For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.