History Map

Optionally referenced from the Archive Collection tab of the ROC Protocol object. May be used to either append-to or override the internal mapping for a ROC EFM archive.

History Map Configuration

One or more History Map Record objects may be assigned to each History Map object. Click View Children to view/edit the referenced History Map Record objects.

image-20240327-212116.png

Property

Description

Property

Description

Name

Name of this object.

History Point Base

Defines whether the first point is “0” or the first point is “1”. The example above shows ROCLink history configuration, specifically for Segment 6 (called “#6, Segment 6”). The first point (CCF) is listed as point “1”. If “History Point Base” is configured with “0” then in the map it should be referred to as point “0”.

Folder

A reference to the parent folder object.

History Map Record Configuration

Property

Description

Property

Description

RecordId

Name of this object.

Map Type

  • History Point

  • TLP & Archive Type (Default)

Point Type

Specify if Map Type is assigned to “TLP & Archive Type” otherwise leave at 0.

Logical

Specify if Map Type is assigned to “TLP & Archive Type” otherwise leave at 0.

Parameter

Specify if Map Type is assigned to “TLP & Archive Type” otherwise leave at 0.

Archive Type

Should match the archive type as defined in the ROCLink history segment configuration.

  • Accumulated

  • Average (Default)

  • Current

  • Totalize

History or Batch Segment

Should match the ROCLink history segment configuration for that meter.

History Point

The index down History Point List in ROCLink if Map Type is assigned to the History Point value. Zero if Map Type is TLP.

Field Identifier

The EFM FlowCal field identifier that will be used.

Meter Run

Meter 01-18

History Map

Reference to History Map object.

For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.