ABB® Totalflow

ABB® Totalflow

General Configuration

Property

Description

Property

Description

Name

The name of this item

Enabled

If checked,

Edge ACM will poll this device when running

Device ID

The ID of the End Device

Security Code

Second level of security used by the End Device to allow read and write if security is turned on. Field accepts a four-character ASCII string.

Max Data Block

Defines the maximum data block size, valid values 50-1024. Common values: 128, 256, 512, 1024.

Max Registers

The maximum number of registers to request in a single poll message, valid values 1-255

Tag Groups

The Tag Group(s) that are associated with this device. Edge ACM will only poll this device for the tags in the groups selected here

Connection Settings

The object that contains the connection settings Edge ACM will use to connect to the End Device

Folder

The parent folder for this item

Comm Stats

See the Comm Stats entry on the Common Tabs page: Common Tabs | Comm Stats

 

For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.