DF1

DF1

General Configuration

 

device.png

 

Property

Description

Name

The name of the item

Enabled

If checked, Edge ACM will poll this device when running

Description

Optional description. This does not affect the object settings.

Slave Type

Select the Slave Type. There are 2 options.

  1. PLC/SLC Channel 0

  2. Date Highway Module

Host ID

Set Host ID.

Minimum: 0

Maximum: 255

Slave ID

Set Slave ID.

Minimum: 0

Maximum: 255

Dest ID

Set Dest ID.

Minimum: 0

Maximum: 255

Error Check Type

Set Error Check Type. There are 2 options.

  1. BCC

  2. CRC

Comm Mode

Select the Comm Mode. There are 3 options.

  1. Master (Half Duplex)

  2. Point-to-Point (Full Duplex)

  3. Peer-to-Peer (Full Duplex)

Processor

Select the processor. There are 11 options.

  1. 1774-PLC

  2. ControlLogix

  3. Micro Logix 1000

  4. Micro Logix 1200

  5. Micro Logix 1500

  6. PLC-2

  7. PLC-5

  8. SLC-500

  9. SLC-5/03

  10. SLC-5/04

  11. SLC-5/05

Primary Connection Type

Set the primary connection type. There are 2 options.

  1. Serial

  2. Ethernet

Secondary Connection Type

Set the secondary connection type. There are 2 options.

  1. Serial

  2. Ethernet

Max Data Bytes

Used to control the maximum number of data bytes requested from the PLC. The length is capped at this setting or the the maximum supported for the selected processor.

Minimum: 0

Maximum: 255

ASCII Addr

Set the Ascii Addr. There are 2 options.

  1. Logical Binary

  2. Logical ASCII

Word Range

Set the Word Range RW. There are 2 options.

  1. Typed

  2. Word Range

Processor Slot Number

Set Processor Slot Number.

Minimum: 0

Maximum: 255

Protocol Options - Enhanced logging for EtherNetIP/CIP message traffic

Check to enable enhanced logging for EtherNetIP/CIP message traffic.

Tag Groups

The Tag Group(s) that are associated with this device. Edge ACM will only poll this device for the tags in the groups listed here.

Connection Settings

The object that contains the connection settings Edge ACM will use to connect to the End Device.

Folder

The parent folder for this item.

Logging

 

logging.png

 

Property

Description

Property

Description

Logging

Logging from the perspective of this device object.

  • Errors. When selected, protocol and operation errors are logged.

  • Send messages. When selected, contents of poll request messages are logged.

  • Receive messages. When selected, contents of complete responses (including errors) are displayed in the log viewer.

  • Device and item activity. When selected, ACM will generate the appropriate log message when items or devices are removed, added, activated, or deactivated.

  • Communication status changes. When selected, ACM will log whenever communication status changes from bad to good or vice-versa.

  • Data values received from device. When selected, an item’s raw value, data type and quality will be logged after a poll that receives a good response or a poll that receives no response. The value will be in raw units.

  • Data values sent to device. When selected, an item’s value will be logged when the publisher writes to an item, but before the write message is sent to the device. The value will be in raw units.

  • Data values written by clients. When selected, an item’s value and data type will be logged when a publisher writes to an item, but before the write message is sent to the device. The value logged will be in engineering units.

  • Data values sent to clients. When selected, an item’s data value, data type and quality will be logged after polling of such item is complete. This log is from host level. The value logged will be in engineering units (if it differs from the raw units used when writing the value to the device).

  • Configuration changes. When selected, eACM will produce a log entry logging the configuration that was loaded on startup.

  • Unsolicited messages from device. When selected, a message will be displayed when the device initiates a request to be polled (often called a report by exception).

  • Items in messages. When selected, a message will be displayed when items are added or removed which changes the contents of poll request messages.

  • Warnings. When selected, a warning will be logged when eACM detects a potential problem, eACM may continue requested processes.

  • Suppress time sync detail. When selected, eACM will not log detailed messages pertaining to what is happening when a time sync occurs.

  • Suppress write entries

Comm Stats

See the Comm Stats entry on the Common Tabs page: Common Tabs | Comm Stats

For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.