See the Common Device Configuration guide for assistance configuring the General, Options, Details, and Logging tabs. See the Connection/Schedule page for assistance with the Connection tab. |
See the Common Modbus Configuration (Device Tab) page.
Default = Not selected. Select this to configure and allow requests to be made.
Click to select or create the Connection Object assigned to this device. See the Time Synchronization section for more details.
Select the desired Time Synchronization Interval relating to the Schedule object assigned on the Connection tab. Time Synchronization checks occur on the frequency of this interval.
Default = UTC-06:00 Central Time (US & Canada).
Default = Not selected. Select this if the device does not send a response or acknowledgment to a time sync command.
Select 'Separate' if date and time are addressed separately. Select 'Combined' if date and time are stored in one location.
The format of the date value (example: YYMMDD).
The I/O address in the device that contains the date.
The format of the time value (example: HHMMSS).
The I/O address in the device that contains the time.
Date/Time Format.
Modbus register for Date/Time.
If Date or Time are in separate 16 bit consecutive registers (Example:6101=Hour, 6102=Minute, 6103=Second), then Time Format would be “HHmmss”, and Time Location would be “6101[3]”. If Date and Time are in combined type then the timestamp format could be “JULIAN” (seconds since midnight of 01/01/1970), “4BYTEDATE” (BSAP) or string (MMddyyHHmmss). |
Select the desired Interval relating to the Schedule object assigned on the Connection tab. History record collection will occur at a frequency based on the configuration of this interval.
If multiple schedule objects are selected for this device (Primary, Secondary, or Alternate), ensure that each Schedule has the same interval numbers configured. |
Default = Not selected. Select this option if this device splits each meter's history across two archives (e.g. 701 and 702)
Default = "As-is". Select "As- is" to publish records with data as it comes from the device. Select "Start of interval" to combine two records into one record with correct hourly values (instead of accumulations).
Default = Not selected. Select if this device is a chromatograph which uses a history pointer that wraps back to one after it reaches 9999.
Check Collect Events if required.
Click to select or create an EFM Alarm Configuration. See the EFM Alarm Configuration section for more details.
Click to select or create an Archive Access. See the Archive Access section for more details.
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
Click to select or create an EFM Event Configuration. See the EFM Event Configuration section for more details.
Default = Not selected. Select to include the record index number.
Default = Not selected. Select to configure the meter collection.
Click to select or create the Meter Object assigned to selected meter run number. See the Meter section for more details.
Click to select or create a Archive Access. See the Archive Access section for more details.
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
Click to select or create the GC object that is configured with IO addresses for gas component data. See the Gas Chromatograph section for more details.