See the Common Device Configuration guide for assistance configuring the General, Options, Details, and Logging tabs. See the Connection/Schedule page for assistance with the Connection tab. |
See the Common Modbus Configuration (Device Tab) page.
Enable Time Synchronization
Default = Not selected. Enable this to configure and allow requests to be made.
Click to select or create the Connection Object assigned to this device. See the Time Synchronization section for more details.
Select the desired Time Synchronization Interval relating to the Schedule object assigned on the Connection tab. Time Synchronization checks occur on the frequency of this interval.
Default = UTC-06:00 Central Time (US & Canada).
Default = Not selected. Select this if the device does not send a response or acknowledgment to a time sync command.
Date and time type. Select 'Separate' if date and time are addressed separately. Select 'Combined' if date and time are stored in one location.
The format of the date value (example: YYMMDD).
The I/O address in the device that contains the date.
The format of the time value (example: HHMMSS).
The I/O address in the device that contains the time.
Date/Time Format.
Modbus register for Date/Time.
If Date or Time are in separate 16 bit consecutive registers (Example:6101=Hour, 6102=Minute, 6103=Second), then Time Format would be “HHmmss”, and Time Location would be “6101[3]”. If Date and Time are in combined type then the timestamp format could be “JULIAN” (seconds since midnight of 01/01/1970), “4BYTEDATE” (BSAP) or string (MMddyyHHmmss). |
Select the desired Interval relating to the Schedule object assigned on the Connection tab. History record collection will occur at a frequency based on the configuration of this interval.
Check Collect Events if required.
Click to select or create a EFM Alarm Configuration. See the EFM Alarm Configuration section for more details.
Click to select or create a Archive Access. See the Archive Access section for more details.
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
Click to select or create a EFM Event Configuration. See the EFM Event Configuration section for more details.
Select the unsolicited message format for this device if it supports cryouts.
Default = Not Selected. Select to include the record index number.
Click to select or create the Meter Object assigned to selected meter run number.
Default = Not selected. Select to configure collection.
The type of data in the archive.
Click to select or create an Archive Access. See the Archive Access section for more details.
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
Default = Not selected. Select to configure GC.
Selected hourly GC for this archive.
Click to select or create the GC object that is configured with IO addresses for gas component data.
See the Gas Chromatograph section for more details.
Default = Not selected. Select to configure collection.
The type of data in the archive.
Click to select or create an Archive Access. See the Archive Access section for more details.
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
Default = Not Selected. Select to configure GC.
Selected daily GC for this archive.
Click to select or create a Archive Access. See the Archive Access section for more details.
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
The RTU Config tab is used in conjunction with the upper level RTU Configuration tab to set up collection and downloading of configuration register data. Both tabs must be configured correctly in order for the functionality to work.
Default = Not selected. Select to automatically read the configuration register values and store them in a persistent file.
Select the desired Interval relating to the Schedule object assigned on the Connection tab. RTU Read Configuration will occur at a frequency based on the configuration of this interval.
Default = Not selected. Select to allow the writing of configuration register data to the RTU.