Time Synchronization Configuration

Click Image Modified to select or create the Connection Object assigned to this device. See the Time Synchronization section for more details.

Time Synchronization Interval

Select the desired Time Synchronization Interval relating to the Schedule object assigned on the Connection tab. Time Synchronization checks occur on the frequency of this interval.

Time Synchronization Priority

  • Low. Queues up with other Low priority items.
  • Medium (Default). Interrupts Low priority items, and queues up with other Medium priority items.
  • High. Interrupts Medium and Low priority items, and queues up with other High priority items.

Timezone

Default = UTC-06:00 Central Time (US & Canada).

Archive Collection Tab

Collection Priority

  • Low (Default).Queues up with other Low priority items.
  • Medium. Interrupts Low priority items, and queues up with other Medium priority items.
  • High. Interrupts Medium and Low priority items, and queues up with other High priority items.

Collection Options

  • Acknowledge Alarms: Default = Selected. Acknowledge alarms after retrieval and storage. Note, if this option is not selected, the same alarms may be retrieved more than once.
  • Acknowledge Events: Default = Selected. Acknowledge events after retrieval and storage. Note, if this option is not selected, the same events may be retrieved more than once.
  • Purge DLogs :Default = Not selected. Select to purge records from the data log after retrieval and storage.
  • Publish Audit Batch Fields: Default = Not selected. Select to publish batch related fields contained in audit records. Note, valid only for devices that support batch.
  • Publish Density to Observed Density with Liquid Meters: Default = Not Selected. When selected, the Density value will be published to Observed Density for Liquid Meters.
  • Adjust Record Timestamp: Default = Not selected. Select to round up hourly and daily ending timestamps if they are within one second of the hour.
  • Publish Raw Event Data: Default = Not selected. Select to publish raw event bytes as a field in the event record.
  • Use Leading Timestamp: Default = Not selected. Select to use a leading timestamp in the EFM Record (this setting only applies to 32 Bit Controllers with Flow Computer versions 6.70 and higher).
  • Publish User Data Fields: Default = Not selected.  Select to publish user data fields in audit and batch records for liquid and water runs.

Alarm/Event Block

Default = 13. The number of alarm or event records to retrieve in a single request (this setting only applies to devices with Flow Computer version 5.20 or higher).

History Block Size

Default = 5. The number of hourly or daily records to retrieve in a single request (this setting only applies to devices with Flow Computer version 5.20 or higher).

Gas Composition Format

Default = Percent. Select the desired option to publish gas component data in percent or mole fraction values.

Collection Intervals

Select the desired Interval relating to the Schedule object assigned on the Connection tab. Record collection will occur at a frequency based on the configuration of this interval.

Meter Runs Tab


Meter 1-

...

20

Select the Meter number to edit.

Meter Object

Click Image Modified to select or create the Meter Object assigned for the meter run. See the Meter section for more details.

Collect Meter 1 Alarm

Default = Not selected. Select to configure and collect alarms for the selected meter run.

Alarm Archive

Click Image Modified to select or create an Archive Limits. See the Archive Limits section for more details.

Collect Meter 1 Daily

Default = Not selected. Select to configure and collect daily records for the selected meter run.

Daily Archive

Click Image Modified to select or create an Archive Limits. See the Archive Limits section for more details.

Collect Meter 1 Event

Default = Not selected. Select to configure and collect event records for the selected meter run.

Event Archive

Click Image Modified to select or create an Archive Limits. See the Archive Limits section for more details.

Collect Meter 1 Hourly

Default = Not selected. Select to configure and collect hourly records for the selected meter run.

...

This option is only valid for gas runs and 32 bit controllers running Flow Computer version 6.77 and higher.

Collect Meter 1 Batch

Default = Not selected. Select to configure and collect batch records for the selected meter run.

Batch Archive

Click Image Modified to select or create an Archive Limits. See the Archive Limits section for more details.

Data Logs Tab

Collect DLogs 1-16

Default = Not selected. Select to collect DLog.

DLog Archive

Click Image Modified to select or create an Archive Limits. See the Archive Limits section for more details.

DLog Meter 1-16

Click Image Modified to select or create the Meter Object assigned for the meter run. See the Meter section for more details.

DLog Meter 1-16 Column Header

...