See the General Object Common Device Configuration guide for assistance configuring the General, Options, Details, and Logging tabs.   See See the Device Object General Connection/Schedule page for assistance with the Connection tab.

Device Tab

See the  Common Modbus Configuration (Device Tab)  page.

Info
titleDevice Tab Register Set Note

The Register Set should be set to the Scanner 1150 Register Set. If no register sets are available, use the Import/Export tool to import the “Import_ModbusRegisterSets.txt” file in the Templates folder of the ACM Client folder installation.

...

Time Synchronization Configuration

Click Image Modified to select or create the Connection Object assigned to this device. See the Time Synchronization section for more details.

Time Synchronization Interval

Select the desired Time Synchronization Interval relating to the Schedule object assigned on the Connection tab. Time Synchronization checks occur on the frequency of this interval.

Time Synchronization Priority

  • Low. Queues up with other Low priority items.
  • Medium (Default). Interrupts Low priority items, and queues up with other Medium priority items.
  • High. Interrupts Medium and Low priority items, and queues up with other High priority items.

Timezone

Default = UTC-06:00 Central Time (US & Canada).

Archive Collection Tab

Collection Priority

  • Low (Default).Queues up with other Low priority items.
  • Medium. Interrupts Low priority items, and queues up with other Medium priority items.
  • High. Interrupts Medium and Low priority items, and queues up with other High priority items.

Collect

Default = Not selected. Select each type to collect.

Collection Intervals

Select the desired Interval relating to the Schedule object assigned on the Connection tab. Record collection checks occur on the frequency of this interval.


Info
titleNote

If multiple schedule objects are selected for this device (Primary, Secondary, or Alternate), ensure that each Schedule has the same interval numbers configured.

Retrieval batch size

Default = 24.

Stop retrieval when a blank timestamp is found 

Default = Selected.

Publish partial alarms and events

Default = Not Selected.  Select this to publish alarms and events even if retrieval can't be completed. This may cause gaps or lost records.

Meter Runs Tab

Meter

Meter Object assigned. Click Image Modified to select or create one. See the Meter section for more details.

Periodic/Daily/Event/Alarm Archive

Click Image Modified to select or create a Configurable Archive. See the Configurable Archive section for more details.