Table of Contents |
---|
...
|
...
|
...
|
...
|
Info |
---|
See the General Object Common Device Configuration guide for assistance configuring the General, Options, Details, and Logging tabs. See See the Device Object General Connection/Schedule page for assistance with the Connection tab. |
Device Tab
See the Common Modbus Configuration (Device Tab) page.
Info | ||
---|---|---|
| ||
The Register Set should be set to the Scanner 1150 Register Set. If no register sets are available, use the Import/Export tool to import the “Import_ModbusRegisterSets.txt” file in the Templates folder of the ACM Client folder installation. |
...
Time Synchronization Configuration
Click to select or create the Connection Object assigned to this device. See the Time Synchronization section for more details.
Time Synchronization Interval
Select the desired Time Synchronization Interval relating to the Schedule object assigned on the Connection tab. Time Synchronization checks occur on the frequency of this interval.
Time Synchronization Priority
- Low. Queues up with other Low priority items.
- Medium (Default). Interrupts Low priority items, and queues up with other Medium priority items.
- High. Interrupts Medium and Low priority items, and queues up with other High priority items.
Timezone
Default = UTC-06:00 Central Time (US & Canada).
Archive Collection Tab
Collection Priority
- Low (Default).Queues up with other Low priority items.
- Medium. Interrupts Low priority items, and queues up with other Medium priority items.
- High. Interrupts Medium and Low priority items, and queues up with other High priority items.
Collect
Default = Not selected. Select each type to collect.
Collection Intervals
Select the desired Interval relating to the Schedule object assigned on the Connection tab. Record collection checks occur on the frequency of this interval.
Info | ||
---|---|---|
| ||
If multiple schedule objects are selected for this device (Primary, Secondary, or Alternate), ensure that each Schedule has the same interval numbers configured. |
Retrieval batch size
Default = 24.
Stop retrieval when a blank timestamp is found
Default = Selected.
Publish partial alarms and events
Default = Not Selected. Select this to publish alarms and events even if retrieval can't be completed. This may cause gaps or lost records.
Meter Runs Tab
Meter
Meter Object assigned. Click to select or create one. See the Meter section for more details.
Periodic/Daily/Event/Alarm Archive
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.