Recommended Configuration Steps
...
Info |
---|
See the General Object Configuration |
...
Options Tab
See the Device Object General Options page.
Details Tab
See the Device Object General Details page.
Logging Tab
See the Device Object General Logging page.
Connection Tab
...
guide for assistance configuring the General, Options, Details, and Logging tabs. See the Device Object General Connection/Schedule page for assistance with the Connection tab. |
Device Tab
See the Common Modbus Configuration page.
...
Time Synchronization Configuration
Click to select or create the Connection Object assigned to this device. See the Time Synchronization section for more details.
Time Synchronization Interval
Select the desired Time Synchronization Interval relating to the Schedule object assigned on the Connection tab. Time Synchronization checks occur on the frequency of this interval.
Time Synchronization Priority
- Low. Queues up with other Low priority items.
- Medium (Default). Interrupts Low priority items, and queues up with other Medium priority items.
- High. Interrupts Medium and Low priority items, and queues up with other High priority items.
Timezone
Default = UTC-06:00 Central Time (US & Canada).
Device Time Read Start Address
Default = 40101.
Device Time Read End Address
Default = 40106.
Device Time Write Year Address
Default = 40093.
Device Time Write Month Address
Default = 40094.
Device Time Write Day Address
Default = 40095.
Device Time Write Hour Address
Default = 40096.
Device Time Write Minute Address
Default = 40097.
Device Time Write Second Address
Default = 40098.
Archive Collection Tab
Daily Collection Priority
- Low (Default).Queues up with other Low priority items.
- Medium. Interrupts Low priority items, and queues up with other Medium priority items.
- High. Interrupts Medium and Low priority items, and queues up with other High priority items.
Daily Collection Interval
Select the desired Daily Interval relating to the Schedule object assigned on the Connection tab.
Contract Hour
Default = 0.
Day Request Address
Default = 40099.
Day Loaded Address
Default = 40107.
Record Load Timeout
Default = 5.
Meter Runs Tab
Meter Run Settings 1-10
Enable
Default = Not Selected.
Meter
Meter Object assigned. Click to select or create one. See the Meter section for more details.
Daily History Archive
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
Daily History Start Address
Default = 40108 - 40252.
Daily History End Address
Default = 40123 - 40267.
Gas Chromatograph Tab
GC Read Config
Click to select or create the GC object that is configured with IO addresses for gas component data. See the Gas Chromatograph section for more details.
GC Write Config
Click to select or create the GC object that is configured with IO addresses for gas component data. See the Gas Chromatograph section for more details.
GC Write Staged Address
Default = 22. Address used to inform device that GC data has been written.
GC Write Status Address
Default = 15. Address used by device to signal GC write success/failure.
GC Write Status Check Delay
Default = 0. Delay (in ms) between staging GC write and checking status.