See the Common Device Configuration guide for assistance configuring the General, Options, Details, and Logging tabs. See the Connection/Schedule page for assistance with the Connection tab. |
Device Tab
Default = 33333. The five digit instrument access code for the device.
The sign-on code is optional. If left blank, ACM will negotiate the correct code to use with the device based on the configured device type.
Default = 00000000. Site ID 1 of 2 to provide verification/identify of which Romet device to communicate with.
Default = 00000000. Site ID 2 of 2 to provide verification/identify of which Romet device to communicate with.
Default = Not selected. If the Romet device is communicating through a Mercury MI Modem then select this and enter the Port letter and the MI Modem ID for that device.
When doing cry-outs, set the MI modem port in the drop down list to the one the Romet device is attached to. This option is only relevant for processing unsolicited messages and will not matter when simply polling through an MI modem.
Default = A. Mercury Modem Port Number.
Default = 10000000. Mercury Modem ID Number.
Settings that determine how or if certain field values will be included in the historical published data. Archive collection must be enabled, on the Archive Collection tab, for these settings to take effect.
Publish the raw record timestamp.
Publish the historical record log trigger and alarm field.
Publish the instrument type.
Publish the Site Id 1 value.
Publish the Site Id 2 value.
Publish the alarm field contained in historical EFM records.
Default = UserFloat1. Click to select the identifier to use when publishing the Corrected Flow field from the Daily EFM history record.
Default = Not selected. This prints very verbose messages in the ACM log about the current state of the protocol engine and/or EFM upload.
Default = Selected. When un-selected, ACM will poll for meter configuration data after a communication failure.
Default = Not selected. Publish the audit trail item as column names in CSV report.
Default = Not selected. This option will produce an extra column for each audit trail item with the current audit trail item number.
Default = Not selected. This option will produce an extra column for each audit trail item with the current unit used for that audit trail item, if known.
Default = Not selected. This option changes the units of some published items.
Default = Not selected. By default, ACM will convert the KFactor value from Pulses per Cubic Meters to Pulses per Cubic Feet. Enable this option to publish the KFactor in Pulses per Cubic Meter when the field device is using Pulses per Cubic Meter units.
Default = Not selected. This option will cause history records generated by events or alarms to be published along with time triggered ones.
Default = Not selected. This option will initiate a history upload after a user initiated demand poll completes.
Default = Not selected. Select this to configure and allow requests to be made.
Click to select or create the Connection Object assigned to this device. See the Time Synchronization section for more details.
Select the desired Time Synchronization Interval relating to the Schedule object assigned on the Connection tab. Time Synchronization checks occur on the frequency of this interval.
Default = UTC-06:00 Central Time (US & Canada).
Click to select or create the Meter Object assigned to the meter. See the Meter section for more details.
The Meter object may be configured with an Advanced Meter Configuration object. This will allow user configured values to be published in addition to pre-defined meter configuration properties read from the RTU. |
Select the desired Meter Configuration, Audit, Alarm, and Event Interval relating to the Schedule object assigned on the Connection tab.
Select to edit the settings for either Audit 1 (Hourly) or the Daily audit.
Default = Not selected. Select to configure collection.
Click to select or create an Archive Limits object. See the Archive Limits section for more details.