See the Common Device Configuration guide for assistance configuring the General, Options, Details, and Logging tabs. See the Connection/Schedule page for assistance with the Connection tab. |
Default = 1.
Default = Not selected. Select this to allow the RTU group address to be used and enter the appropriate group address.
Default = Not selected. Select this to require the device to be waken before regular communication. This feature is used mostly when the device is setup for power saving mode.
Default = 10. The period of time in seconds to allow for the device to respond to a wake up request.
Default = 50. Retry time out on the device wake up message.
Default = 1. Total number of trends configured in the device including both hourly and daily trends.
Default = Not selected. Enable this option to allow device configuration 1 and 2 to be retrieved on interval defined.
Default = Interval 10. When the defined interval is due, device configuration 1 and 2 will be set to be retrieved on the next polling of base poll items.
Default = Not selected.
Default = Not selected.
Default = Not selected. Select this to configure and allow requests to be made.
Click to select or create the Connection Object assigned to this device. See the Time Synchronization section for more details.
Select the desired Time Synchronization Interval relating to the Schedule object assigned on the Connection tab. Time Synchronization checks occur on the frequency of this interval.
Default = UTC-06:00 Central Time (US & Canada).
Select the desired Interval relating to the Schedule object assigned on the Connection tab.
Default = Not selected. Select this to configure archive and meter for collection.
Click to select or create an Archive Limits. See the Archive Limits section for more details.
Click to select or create the Meter Object assigned to meter 1. See the Meter section for more details.
Default = Not selected. Select to configure the archive and the meter for collection.
Click to select or create an Archive Limits. See the Archive Limits section for more details.
Click to select or create the Meter Object assigned to the production meter. See the Meter section for more details.
Meter 1-32. Select the meter run to configure.
Click to select or create the Meter Object assigned to this meter run number. See the Meter section for more details.
Click to select or create an Archive Limits. See the Archive Limits section for more details.
The Daily and Hourly Trend tabs are similar.
Default = Not selected. Enable to configure collection.
Click to select or create the Meter Object assigned to trend collection. See the Meter section for more details.
The trend record number for trend daily/hourly retrieval. Note, the trend record number is 0 based.
Click to select or create an Archive Limits. See the Archive Limits section for more details.