Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

 Table Of Contents

Overview

The defaults in the Properties tab will function for most systems.

Note

If changes have been applied, click the button to Save the current configuration on screen. If the changes have not been saved, a notification window will appear prompting a Save or Cancel choice. In case the default properties need to be restored, click the Reset button.

Gas Analysis Processing Blackout Periods Properties

There are four available blackout periods during which no write requests will be processed or sent. The display shows a short description of the blackout.

To alter it:

  1. Click the editing box ... to the right of the short description
  2. Make the alterations
  3. Click Save and then Save again on the parent page.

Gas Analysis Write File Service

There are eight settings associated with the Gas Analysis Write File Service that can be modified by the users:

  1. Archive Completed Folder: The Archive folder for files that have succeeded with at least one request.
  2. Archive Failed Folder: The Archive folder for the files that have failed to create any requests.
  3. Field Delimiter: The field delimiter used in the file. The default setting is (,).
  4. Field Mapping: The column mapping scheme used to read values from each file line into a predetermined GC Write Request field. By default: GCIDENTIFIER,ARGON,CO,CO2,ETHANE,H2,H2O,H2S,HELIUM,IBUTANE,IPENTANE,METHANE,N2,NBUTANE,NDECANE,NEOPENTANE,NHEPTANE,NHEXANE,NNONANE,NOCTANE,NPENTANE,O2,PROPANE,HEATINGVALUE,SPECIFICGRAVITY
  5. Has Column Headers: Set to true if the first row of the file contains column headers. The default setting is True. To change this setting, select the cell marked “True” and use the drop-down menu.
  6. Import Folder: The import folder for new files to be processed.
  7. Meter Resolution Mode: Resolves the meters in ACM by RecordField or FileName. The default setting is RecordField. To change this setting select the cell marked RecordsField and type in FileName.
  8. Validation Tolerance: The value +/- of the mole component total used to create a tolerance window. 100 would let any sum validate. The default setting is 100.

Gas Analysis Writes

There are six settings associated with Gas Analysis Writes that can be modified by users:

  1. Exclude Non-External: Use the External GC Reference or External Meter Reference properties to find the correct meter name and device. The default setting is False. To change this setting, select the cell marked “False” and use the drop-down menu.
  2. Fail Orphaned Requests: Any gas analysis writes that occur during a server shutdown will be marked as “failed”. The default setting is False. To change this setting, select the cell marked “False” and use the drop-down menu.
  3. FlowCal Area Index: The FlowCalScadaRequest measurement area index to use for requests. Leave empty to specify all areas. The default setting is empty.
  4. Max Concurrent Writes: The maximum number of gas analysis writes that can be queued simultaneously. The default setting is 25. To change this setting, select the cell with the numerical value and use keyboard input.
  5. Request Service Interval Timer: The interval time (in seconds) for the asiGCRequestManager service to process requests. Default is 30. Changes require a restart of the service.
  6. Trace Logging: This enables logging of gas analysis related progress messages. The default setting is False. To change this setting, select the cell marked “False” and use the drop-down menu.

Gas Analysis Writes Retry

There are six settings associated with the Gas Analysis Writes Retry that can be modified by the users:

  1. Max Tries: The maximum number of tries to attempt a gas analysis write for a specific request. This is not used when Switch to Slow Mode is enabled. The default value is 3.
  2. Slow Timeout: The maximum time (in seconds) to allow for a gas analysis write to complete before putting in the retry list. The default value is 300.
  3. Switch to Slow Timeout: The maximum time (in seconds) to allow the Write Timeout to complete a gas analysis write before switching to the Slow Timeout. The default value is 500.
  4. User Switch to Slow Mode: Enable Slow Timeout schedule for request and retry attempts one the Switch to Slow Timeout has triggers. Max Tries is ignored when Enabled. The default value is False.
  5. Write Timeout: The maximum time (in seconds) to allow for a gas analysis write to complete before putting it in the retry list. The default value is 180.

Report Services

There are two settings associated with the Report Services that can be modified by the users:

  1. Archive Schedule: This enables users to configure when the Archive Manager process runs.
    1. Do not run automatically:  The archive process will only run if triggered to run manually
    2. Run every hour at # minutes past the hour:  If 55 is entered for minutes, the archive process will run at 1:55, 2:55, 3:55 and so on.
    3. Run once a day at entered time
  2. Detail Logging: This option allows users to show logging messages for starting and completing calls through the Report Service, such as, Archive Management and Scheduled Reports.

Server

The following settings associated with Server can be modified by users:

  1. DataPath: This points to the folder used for data file storage; includes View filters and RTU configuration files. The default data path is: C:\ProgramData\AutoSol\Communication Manager\7\DataFiles
  2. DotNaming: This option allows “Object.Item” naming syntax. Otherwise, “[Object]Item” syntax must be used. The default value is True.
  3. LogStartupConfig: This option allows users to log all configuration properties during server startup. The default setting is False.

    Important!

    Enabling LogStartupConfig may slow down the startup process.

  4. OPC Trace: OPC trace information between clients and server is possible when this option is enabled. The default setting is False

    Important!

    Enabling OPC Trace may produce large log files and add significant overhead to the server.

  5. SQLTimeout – Bulk Insert: This is the maximum time, in seconds, allowed for a SQL command to complete. The default value is 60.
  6. SQLTimeout – Publisher Commands: This is the maximum time, in seconds, allowed for a Publisher SQL command to complete. The default value is 60.
  7. SQLTimeout – Report Commands: This is the maximum time, in seconds, allowed for a Report SQL command to complete. The default value is 60.
  8. UniqueNamesWithinType:Enabling this option forces unique object names within each object type. The default setting is False.
  9. UseCacheForDeviceReads: This property is not visible in the Server properties list. It controls how ACM provides data to OPC clients that request a read from field devices. The default setting is False, which makes ACM follow the OPC specification for data updates. If OPC clients request a read from field devices while this setting is True, ACM will update OPC clients with data from its internal cache instead of polling field devices for data. Contact technical support if you believe this alternate behavior will benefit your application.

Service Ports

The TCP ports used for communication between the ACM Configuration client and the server components can be configured in the Service Ports section. If another application on the computer is already using one of these ports, the associated service will not be able start successfully. The port numbers to use can be modified in this section:

  • Archive Service Tcp Port: The port used to connect to the asiREPORTSERVER.exe service. This service houses both reporting and archive management features.
  • Command Service Tcp Port: The port used to connect to the asiCONFIGSERVER.exe service. This services houses both the configuration and command features.
  • Config Service Tcp Port: The port used to connect to the asiCONFIGSERVER.exe service.
  • Item Service Tcp Port: The port used to connect to the asiITEMSERVER.exe service.
  • Logging Service Tcp Port: The port used to connect to the asiLOGSERVER.exe service.
  • Report Service Tcp Port: The port used to connect to the asiREPORTSERVER.exe service.

Totalflow Laptop File Import Service

These are settings associated with TotalFlow Laptop File Import Service that can be modified by users:

Configuration: Select the ellipses to open the configuration properties of this service.

  • Import file folder: The folder where the service looks for the files to import. You have to create this folder if it does not already exist.
  • Completed File Folder: the folder where import files are moved if everything works successfully and data is imported.
  • Failed file folder: The folder where import files are moved if something fails.
  • Frequency to check for new files: A timer. The service looks in the import folder at this interval to see if new files are available.
  • Prevent Duplicate Records: An option to skip importing history records if they are already in our database. (If you have already imported the same file, or there is some overlap in multiple files, this should be enabled.)
  • Update History Position: Option to update the saved history position in ACM, this option should typically be enabled.
  • Enable Diagnostic Logging: Extra logging for troubleshooting.
  • No labels