 Table Of Contents

Overview

This object is used to map events and values from the device to defined EFM events and values.

Configuration

General Properties

See General Object Configuration page.

EFM Event Configuration Tab

Click Edit Configuration to open the EFM Event Configuration Record Collection window and view the event configuration records. 

In the EFM Event Configuration Record Collection window:

  • Click Add to add new event configuration record.
  • Click Add Multi to add multiple new event configuration records.
  • Click the up arrow or down arrow to move an event configuration record up or down by one position in the collection.
  • Click Remove to delete an event configuration record.
  • Click Copy to add a copy of the selected event configuration record to the end of the collection.
  • Click Tabular Display to view all New Record items at once.
  • Click Close to return to the EFM Event Configuration tab.

Saving Record Collection Changes

Once back in the the EFM Event Configuration tab, click the Save button  to save any changes made to the record collection.

New Record Configuration

All Meter Runs

Default = False. Select True to publish event record to all meter runs. 

Data Source

The value for an event record from the device that should be mapped to the selected Field Identifier.

Event Description

Descriptive string to be published as part of the mapped event record.

Field Identifier

Identifier for the EFM field to which the event record should be mapped.

RecordId

Name of this record in the collection.

Run Number

The one-based run number for the meter that the event record will be published to, if it is not published to all meter runs.

Translator

The object used to translate the Data Source value of an event record into a defined EFM value.

Click the  and select the appropriate Event Translator object. See Event Translator for more information. 

Unit Identifier

Default = Unitless. Select the unit of the event value from the Custom Unit selection form.