Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Overview

This object is used to map events and their values from the device to defined EFM fields and values when publishing to an EFM file format.

...

Default = False. Select True to publish event record to all meter runs. If this property is false, the 'Run Number' property determines which meter run(s) the event applies to.

Data Source

The value of the field in the event record from the device that maps the event to the selected Field Identifier. Which event record field is used for the Data Source is determined by the Device Protocol.

...

Label used for this event configuration record in the collection.

Run Number

The Enter the meter run number (one-based run number for the meter that the event record will be published to, if it is not published to all meter runsvalue) or collection of meter runs that this event should be published to. The value can be a single run number, such as '1'; or a collection of runs formatted similar to '1,2,3' or '1,3-4'. If the 'All Meter Runs' property is enabled, this property is not used.

Info
titleEnron Modbus Only

Enron Modbus is the only protocol that supports the 'collection' syntax. Other protocols accept only a single run number value.


Translator

The object used to translate the old and new values of an event record into defined EFM values.

Click the Image Modified and select the appropriate Event Translator object. See Event Translator for more information. 

Unit Identifier

Default = Unitless. Select the unit of the event old and new values from the Custom Unit selection form.