  • Added variables Octane, Nonane and Decane to the ROC800L Internal Map.

    Note
    titleEffect on Published Output

    Octane, Nonane and Decane fields will be published in CFX and CSV for ROC devices.


Teledyne CA Protocol

...

  • Improved the error message logged when an item with an incomplete name is added by an OPC client.
  • Corrected an issue that caused the Sinewave item to stop updating after ACM had been running for an extended period of time.
  • Improved the Archive Record deletion process to prevent reduce the likelihood of timeouts.
  • Modified OPC item updates to use the timestamp from a remote device if the device is capable of sending a timestamp with the value.

...

  • Corrected an issue that caused EFM history records to always be published with a value of 60 for the $$Record.Period$$ field.

    Note
    titleEffect on Published Output

    EFM history records are now published with the correct value in the $$Record.Period$$ field.


  • Corrected an issue that prevented the LogTrigger column from appearing on a CSV Audit Report.

    Note
    titleEffect on Published Output

    The CSV audit report will contain the LogTrigger column by default. This may add an additional column to the CSV report.


  • Modified the contents of the LogTrigger column in a CSV Audit Report to contain the entire T&A value.

    Note
    titleEffect on Published Output

    The LogTrigger column in the CSV audit report will now contain the entire T&A field value.


  • Corrected an issue that could cause non-time triggered audit records to be published even when the ACM device object was not configured to do so.

    Note
    titleEffect on Published Output

    Non time-triggered audit records will only be published if the ACM device object is configured to do so.


  • Corrected an issue that caused history upload to continue despite a failure to read audit configuration.
  • Corrected an issue that prevented the K-Factor value from being published.

    Note
    titleEffect on Published Output

    Non time-triggered audit records will only be published if the ACM device object is configured to do so.


Siemens S7 Protocol

  • Resolved an issue with OPC item Read/Write access showing only Writable and not Readable.

Totalflow Protocol

  • Modified the driver to stop history collection if meter configuration retrieval failed and no meter configuration data has been retrieved previously. If meter configuration data has previously been retrieved the history collection will continue.
  • Modified the initial OPC quality of “MoveEvent” to be “Good” to match the other "Move" items.
  • Corrected an issue that caused the "Request 3 days of history when 2 days history is needed" option to be ignored.