See the DF1 Configuration page.

Time Sync Tab

Image RemovedImage Added

Enable Time Synchronization

...

Time Synchronization Configuration

Connection Object assigned to this device. Click Image Modified to select or create one. See the Time Synchronization section for more details.

Time Synchronization Interval

Select the desired Time Synchronization Interval relating to the Schedule object assigned on the Connection tab. Time Synchronization checks occur on the frequency of this interval.

Time Synchronization Priority

  • Low. Queues up with other Low priority items.
  • Medium (Default). Interrupts Low priority items, and queues up with other Medium priority items.
  • High. Interrupts Medium and Low priority items, and queues up with other High priority items.

Timezone

Default = UTC-06:00 Central Time (US & Canada).

Time Sync Read Addresses

Define where ACM can find the PLC’s current time. Data is expected to be in the following order: Year, Month, Day, Hour, Minute, Second.

Time Sync Write Addresses

Define where ACM should write time to set the PLC’s clock.

Archive Collection Tab

Image AddedImage Removed

Collection Priorities

Set the Collection Interval for Daily History, Hourly History, Event, and Meter Config collection.

Collection Intervals

Set the Collection Priority for Daily History, Hourly History, Event, and Meter Config collection.

GC Write Config

Click on Image Modified and to select or create the appropriate Gas Chromatograph object. This object will be used to provide addresses for GC Download (ACM write to PLC).

Collection Limits

Set the Collection Limits for Daily, Event and Hourly.

Set the Record Upload Timeout

The maximum time in seconds allowed for PLC to upload a record from the flow computer.

Meter Runs Tab

Image RemovedImage Added

Meter Run Settings

...

Default = Not Selected. Select to enable collection.

Meter

Click Image Added to select or create the Meter Object assigned to this meter run number.

Click Image Removed to select or create one. See the Meter section for more details.

Alarm/Daily/Event/Hourly/Meter Archive

Click Image Modified to select or create a Configurable Archive. See the Configurable Archive section for more details.