See the Common Device Configuration guide for assistance configuring the General, Options, Details, and Logging tabs. See the Connection/Schedule page for assistance with the Connection tab. |
See the Common Modbus Configuration (Device Tab) page.
This should be set to the “ProSoft Register Set” for non-enhanced modules, and “Prosoft Enhanced Register Set” for enhanced modules. Pre-built Register Sets can be imported from ‘C:\Program Files(x86)\AutoSol\Communication Manager\Client\Templates’ by selecting the ‘Import_ModbusRegisterSets.txt’ import file. |
Select the desired Interval relating to the Schedule object assigned on the Connection tab. Record collection will occur at a frequency based on the configuration of this interval.
Default = Not selected. For non-enhanced: Collect the events and alarms. For enhanced: Collect the events.
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
Default = Not selected. For non-enhanced flow computers, set the site signal register. For enhanced flow computers, commit the event session.
Default = 200. Site signal register for acknowledging events. Only used for non-Enhanced Flow Computers.
Default = Not selected. Select to enable Enhanced Alarm collection. Enhanced Flow Computer only.
Default = Not selected. Select to commit the alarm session and update the index on the flow computer. Enhanced Flow Computer only.
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
Click to select or create the Meter Object assigned for the selected meter run. See the Meter section for more details.
Default = Not selected. Select to configure and collect.
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
Default = 30. The size in WORDs of each hourly record. Only Enhanced flow computer supports values above 40.
Default = 0. The size in bytes of each extended hourly record.
Default = Not selected. Select to configure and collect.
Click to select or create a Configurable Archive. See the Configurable Archive section for more details.
Default = 30. The size in WORDs of each daily record. Only Enhanced flow computer supports values above 40.
Default = 0. The size in bytes of each extended daily record.
Default = Not selected. Select to convert the meter's specific gravity value using the equation: outputSG = ((141.5 / inputSG) * 999.016) - 131.5
Volume and Energy values are frequently archived in two parts (the whole number value and the fraction). If the archive is configured to store these (or any other values) in two parts, any scaling required must be applied to both parts of the value. The selected value for the Hourly and Daily record size must be equal or greater than the total number of bytes of data in the selected Advanced Archive Configuration object. Sample: If the device has 30 bytes of data in each archive, 30 will be selected as the record size. If the device has 34 bytes of data in each archive 40 will be selected as the record size since there is not a 34 selection option. |