Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Collection Priority

  • Low (Default).Queues up with other Low priority items.

  • Medium. Interrupts Low priority items, and queues up with other Medium priority items.

  • High. Interrupts Medium and Low priority items, and queues up with other High priority items.

Collection Intervals

Select the desired collection intervals relating to the Schedule object assigned on the Connection Tab. Collections occur on the frequency of this interval.

Info

If multiple schedule objects are selected for this device (Primary, Secondary, or Alternate) ensure that each Schedule has the same interval numbers configured.

Collect Audits

Default = Not selected. Select to enable and configure collection archives.

Audit Access

Click Image Added to select or create the Archive Access object. See the BSAP Archive Access section for more details.

Audit Archive

Click Image Added to select or create a Configurable Archive. See the Configurable Archive section for more details.

Event Map

Click Image Added to select or create a EFM Event Configuration. See the EFM Event Configuration section for more details.

Alarm Map

Click Image Added to select or create a EFM Alarm Configuration. See the EFM Alarm Configuration section for more details.

PGAS Flow Extension Filter Type

Select the filtering algorithm to apply to the Flow Extension value for the PGAS EFM format.

  • No Filter (Default)

  • Standard Filter

  • Teleflow Filter