Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info

See the General Object Configuration

...

Options Tab

See the Device Object General Options page.

Details Tab

See the Device Object General Details page.

Logging Tab

See the Device Object General Logging page.

Connection Tab

...

 guide for assistance configuring the General, Options, Details, and Logging tabs.  See the Device Object General Connection/Schedule page for assistance with the Connection tab.

Device Tab

...

Address

The slave address of the controller.

...

Select the type of card buffers to upload.

Buffer Type

Description

Event

Collect the Event buffer. Only applies to controllers that support either function codes FC16EX or FC24. If enabled, event types in the Event Collection group must also be selected.

Pump On

Collect the Pump On buffer.

Shutdown

Collect the Shutdown (Pump Off) buffer.

Present

Collect the Present (Live) buffer.

Downhole

Collect downhole cards in addition to the surface cards. This option is in conjunction with the other buffer type selections: Event, Pump On, Shutdown, and Present. Only applies to the WellPilot RPOC.

Event Collection

Select the type of events to upload. These options only apply if the Card Collection type of Event is enabled.

Event Type

Description

Fault

Collect fault events and associated card data.

Alarms

Collect alarm events and associated card data.

Plain

Collect plain events and associated card data.

Number of Strokes in Set

Enter the number of strokes to upload per card set. Range 0 to 5, with zero signifying to use the maximum allowed.

...