ItemData TypeFBNet VersionDescription
MPCAL1ENG1R4V1, V2Meter parameters calibration engineering value
MPCAL1ENG2R4V1, V2Meter parameters calibration engineering value
MPCAL1ENG3R4V1, V2

Pressure Overrides

ItemData TypeFBNet VersionDescription
V1, V2Meter parameters calibration engineering value
MPCAL1ENG4R4V1, V2Meter parameters calibration engineering value
MPCAL1ENG5R4V1, V2Meter parameters calibration engineering value
MPCAL1SAMPLE1UI2V1, V2Meter parameters calibration sample
MPCAL1SAMPLE2UI2V1, V2Meter parameters calibration sample
MPCAL1SAMPLE3UI2V1, V2Meter parameters calibration sample
MPCAL1SAMPLE4UI2V1, V2Meter parameters calibration sample
MPCAL1SAMPLE5UI2V1, V2Meter parameters calibration sample
MPCAL2ENG1R4V1, V2Meter parameters calibration engineering value
MPCAL2ENG2R4V1, V2Meter parameters calibration engineering value
MPCAL2ENG3R4V1, V2Meter parameters calibration engineering value
MPCAL2ENG4R4V1, V2Meter parameters calibration engineering value
MPCAL2ENG5R4V1, V2Meter parameters calibration engineering value
MPCAL2SAMPLE1UI2V1, V2Meter parameters calibration sample
MPCAL2SAMPLE2UI2V1, V2Meter parameters calibration sample
MPCAL2SAMPLE3UI2V1, V2Meter parameters calibration sample
MPCAL2SAMPLE4UI2V1, V2Meter parameters calibration sample
MPCAL2SAMPLE5UI2V1, V2Meter parameters calibration sample
MPCAL3ENG1R4V1, V2Meter parameters calibration engineering value
MPCAL3ENG2R4V1, V2Meter parameters calibration engineering value
MPCAL3ENG3R4V1, V2Meter parameters calibration engineering value
MPCAL3ENG4R4V1, V2Meter parameters calibration engineering value
MPCAL3ENG5R4V1, V2Meter parameters calibration engineering value
MPCAL3SAMPLE1UI2V1, V2Meter parameters calibration sample
MPCAL3SAMPLE2UI2V1, V2Meter parameters calibration sample
MPCAL3SAMPLE3UI2V1, V2Meter parameters calibration sample
MPCAL3SAMPLE4UI2V1, V2Meter parameters calibration sample
MPCAL3SAMPLE5UI2V1, V2Meter parameters calibration sample
MPCAL4ENG1R4V1, V2Meter parameters calibration engineering value
MPCAL4ENG2R4V1, V2Meter parameters calibration engineering value
MPCAL4ENG3R4V1, V2Meter parameters calibration engineering value
MPCAL4ENG4R4V1, V2Meter parameters calibration engineering value
MPCAL4ENG5R4V1, V2Meter parameters calibration engineering value
MPCAL4SAMPLE1UI2V1, V2Meter parameters calibration sample
MPCAL4SAMPLE2UI2V1, V2Meter parameters calibration sample
MPCAL4SAMPLE3UI2V1, V2Meter parameters calibration sample
MPCAL4SAMPLE4UI2V1, V2Meter parameters calibration sample
MPCAL4SAMPLE5UI2V1, V2Meter parameters calibration sample
MPCAL5ENG1R4V1, V2Meter parameters calibration engineering value
MPCAL5ENG2R4V1, V2Meter parameters calibration engineering value
MPCAL5ENG3R4V1, V2Meter parameters calibration engineering value
MPCAL5ENG4R4V1, V2Meter parameters calibration engineering value
MPCAL5ENG5R4V1, V2Meter parameters calibration engineering value
MPCAL5SAMPLE1UI2V1, V2Meter parameters calibration sample
MPCAL5SAMPLE2UI2V1, V2Meter parameters calibration sample
MPCAL5SAMPLE3UI2V1, V2Meter parameters calibration sample
MPCAL5SAMPLE4UI2V1, V2Meter parameters calibration sample
MPCAL5SAMPLE5UI2V1, V2Meter parameters calibration sample
MPCAL6ENG1R4V1, V2Meter parameters calibration engineering value
MPCAL6ENG2R4V1, V2Meter parameters calibration engineering value
MPCAL6ENG3R4V1, V2Meter parameters calibration engineering value
MPCAL6ENG4R4V1, V2Meter parameters calibration engineering value
MPCAL6ENG5R4V1, V2Meter parameters calibration engineering value
MPCAL6SAMPLE1UI2V1, V2Meter parameters calibration sample
MPCAL6SAMPLE2UI2V1, V2Meter parameters calibration sample
MPCAL6SAMPLE3UI2V1, V2Meter parameters calibration sample
MPCAL6SAMPLE4UI2V1, V2Meter parameters calibration sample
MPCAL6SAMPLE5UI2V1, V2Meter parameters calibration sample
MPCAL7ENG1R4V1, V2Meter parameters calibration engineering value
MPCAL7ENG2R4V1, V2Meter parameters calibration engineering value
MPCAL7ENG3R4V1, V2Meter parameters calibration engineering value
MPCAL7ENG4R4V1, V2Meter parameters calibration engineering value
MPCAL7ENG5R4V1, V2Meter parameters calibration engineering value
MPCAL7SAMPLE1UI2V1, V2Meter parameters calibration sample
MPCAL7SAMPLE2UI2V1, V2Meter parameters calibration sample
MPCAL7SAMPLE3UI2V1, V2Meter parameters calibration sample
MPCAL7SAMPLE4UI2V1, V2Meter parameters calibration sample
MPCAL7SAMPLE5UI2V1, V2Meter parameters calibration sample
MPCAL8ENG1R4V1, V2Meter parameters calibration engineering value
MPCAL8ENG2R4V1, V2Meter parameters calibration engineering value
MPCAL8ENG3R4V1, V2Meter parameters calibration engineering value
MPCAL8ENG4R4V1, V2Meter parameters calibration engineering value
MPCAL8ENG5R4V1, V2Meter parameters calibration engineering value
MPCAL8SAMPLE1UI2V1, V2Meter parameters calibration sample
MPCAL8SAMPLE2UI2V1, V2Meter parameters calibration sample
MPCAL8SAMPLE3UI2V1, V2Meter parameters calibration sample
MPCAL8SAMPLE4UI2V1, V2Meter parameters calibration sample
MPCAL8SAMPLE5UI2V1, V2Meter parameters calibration sample

Pressure Overrides

ItemData TypeFBNet VersionDescription
CPHIGHFASTADJI2V1, V2The amount of adjustment the RTU makes to the CPhighsetpoint for a fast arrival
CPHIGHNOADJI2V1, V2The amount of adjustment the RTU makes to the CPhighsetpoint for a no arrival
CPHIGHSETPOINTI2V1, V2Opens the plunger (sales) valve it the CP >= this set point
CPHIGHSLOWADJI2V1, V2The amount of adjustment the RTU makes to the CPhighsetpoint for a slow arrival
CPLOWFASTADJI2V1, V2The amount of adjustment the RTU makes to the CPlowsetpoint for a fast arrival
CPLOWNOADJI2V1, V2The amount of adjustment the RTU makes to the CPlowsetpoint for a no arrival
CPLOWSETPOINTI2V1, V2Close the plunger (sales) valve if the CP is <= this set point
CPLOWSLOWADJI2V1, V2The amount of adjustment the RTU makes to the CPlowsetpoint for a slow arrival
DPLOWFASTADJI2V1, V2The amount of adjustment the RTU makes to the DPlowsetpoint for a fast arrival
DPLOWNOADJI2V1, V2The amount of adjustment the RTU makes to the DPlowsetpoint for a no arrival
DPLOWSETPOINTI2V1, V2Close the plunger (sales) valve if the DP is <= this set point
DPLOWSLOWADJI2V1, V2The amount of adjustment the RTU makes to the DPlowsetpoint for a slow arrival
FLUIDSLUGSETPOINTR4V1, V2Opens the plunger (sales) valve it the (CP-TP)/(CP-LP) <= this set point
HLINECLEARDELAYR4V1, V2High line pressure shut in clear delay
HLINECLEARSETPOINTR4V1, V2High line pressure clear set point
HLINETIMEI4V1, V2High line pressure delay time on 0.1 seconds
LDIFFTIMEI4V1, V2Low differential pressure delay time in 0.1 seconds
LPHIGHSETPOINTI2V1, V2Close the plunger (sales) valve if the LP is => this set point
LPLOWSETPOINTI2V1, V2Closes the plunger valve if LP <= this set point
MAXCPSHUTDOWNI2V1, V2Contains the integer portion of the maximum CP the RTU allows before shutting the well down for a safety override.
MAXDPSETPOINTR4V1, V2Maximum DP pressure set point
MAXIPSHUTDOWNI2V1, V2Contains the integer portion of the maximum IP the RTU allows before shutting the well down for a safety override
MAXTPSHUTDOWNI2V1, V2Contains the integer portion of the maximum TP the RTU allows before shutting the well down for a safety override
MININJECTPRESSI2V1, V2Minimum injection pressure required before the RTU opens the injection valve
MINTPSHUTDOWNI2V1, V2Contains the integer portion of the minimum TP the RTU allows before shutting the well down for a safety override
MININJECTPRESSI2V1, V2Minimum injection pressure set point
OPENPURGEONARRBOOLV1, V2Not used by the RTU, contents undefined
TPHIGHFASTADJI2V1, V2The amount of adjustment the RTU makes to the TPhighsetpoint for a fast arrival
TPHIGHNOADJI2V1, V2The amount of adjustment the RTU makes to the TPhighsetpoint for a no arrival
TPHIGHSETPOINTI2V1, V2Opens the plunger (sales) valve it the TP >= this set point
TPHIGHSLOWADJI2V1, V2The amount of adjustment the RTU makes to the TPhighsetpoint for a slow arrival
TPLOWFASTADJI2V1, V2The amount of adjustment the RTU makes to the TPlowsetpoint for a fast arrival
TPLOWNOADJI2V1, V2The amount of adjustment the RTU makes to the TPlowsetpoint for a no arrival
TPLOWSETPOINTI2V1, V2Close the plunger (sales) valve if the TP is <= this set point
TPLOWSLOWADJI2V1, V2The amount of adjustment the RTU makes to the TPlowsetpoint for a slow arrival
TPLPDIFFSETPOINTI2V1, V2Opens the plunger (sales) valve it the (TP – LP) >= this set point
USEUTFORLPUI1V1, V2Contains TRUE if the RTU is to use the UT (unit temperature) analog channel for LP overrides, FALSE otherwise

Remote Shutin

ItemData TypeFBNet VersionDescription
PERMITTEDUI2V1, V2Enable remote shut in
REVISIONUI2V1, V2
STATUSUI2V1, V2Status
STRUCTSIZEUI2V1, V2

...