ACM 8.2 Release - May 14, 2021
Installation Notes
If you have a support agreement, the new ACM version can be downloaded by using the monthly login credentials received from your sales representative. For more details, please contact us today.
Components from ACM 8 cannot be combined with components from ACM 7.
New Security Options
ACM now provides security options to control access to ACM from the desktop configuration program and from the mobile app. This also includes an option to control whether administrator accounts have access to ACM.
When security is enabled and this option is not selected, it is possible to configure users and roles such that all users are locked out of the server or that no users can change the configuration.
ACM now supports Dynamic Flow Computers MicroMP3 Modbus with EFM
Supports both the truck ticket mode and the full six meter flow computer mode.
Provides the ability to retrieve and publish daily and monthly batch report records.
Allows for time synchronization.
Features Added
GC Write Service
Adds support for a comma separated list to be used as the Area ID in queries against the Flowcal database for GC Writes. This allows multiple Areas to use the same ACM Server for GC Writes.
LoggingAdds the assembly version number to the source column in the Log Viewer.
All Protocols
Adds the device detail tab fields as OPC Items.
BSAP Protocol
Adds the ability for a user to separately configure whether Serial or Ethernet protocol is used on the primary and/or secondary connections.
Adds support for array items to meter configuration polling.
Adds a configuration item token number to each meter run. This number will be used to replace a token in the items for the meter configuration reads and GC writes, so that a single Meter Configuration or Gas Chromatograph object can be used for multiple meter runs.
DNP3 Protocol
Adds a rule option in the Meter Configuration object for yes/no fields and RelativeDensitySaturationCondition.
Makes FactorFwv and FwvFactorUsed fields interchangeable.
When a Meter Configuration object (the Advanced Configuration assigned to the Meter object) is used to publish meter configuration data, the fields below now use predefined constants for the "Constant" and "Rule" options. For the CSV publisher, that means that these values will be published as the text strings "Yes"/"No" (or "Wet"/"Dry"/"AsDelivered" for RelativeDensitySaturationCondition) if translation is used, and as numeric codes if translation is not used. For the XML publisher, all of the fields below will be now published within the <Common> node, rather than the <Extended> node as some of them were before:
FlowingPressureEffectEnabled, Live Analysis, Live BTU, Live Gravity, Live Temperature, HasDefaultTemperature, UseRTD, FwvFactorUsed, FwvsFactorUsed, HasRTD, TemperatureCompensated, PressureCompensated, FactorFa, FactorFb, FactorFg, FactorFpv, FactorFr, FactorFt, FactorFwv, FactorY, RelativeDensitySaturationCondition
Adds support for new objects, parameters, measurements, and units in Emerson FBx firmware through 02.07.00.80.
Flow Automation Protocol
Adds history collection support for the Flow Automation Williams Gas load.
The CFX publisher will now show valid data for GC data in the meter configuration section where previously it was invalid.
Adds read and write item support for function types Plunger Lift (config and instantaneous) and Drip Control for Flow Automation devices with the Coastal Flow load.
FlowX ProtocolAdds a new command that allows for copying an existing tag file from a configured device.
Micro MP3 Protocol
Adds support for Dynamic Flow Computer's MicroMP3 Liquid Flow Computer using the Modbus/MicroMP3 protocol.
MicroMP3 supports both the truck ticket mode and the full six meter flow computer mode.
MicroMP3 provides the ability to retrieve and publish daily and monthly batch report records.
MicroMP3 allows for time synchronization.
ROC Protocol
Adds a new option "Combine data from all segments into the same archive records" to combine a meter's data from different segments into the same record.
Adds more units for ROC meter configuration such as differential pressure units, uncorrected volume units to the CFX Output.
Adds the ability to set a ROC device date/time to any value required via new Extended OPC tag ClockSet.
Adds support for publishing data to Flowcal Ultrasonic Diagnostic area.
SCADAPack Protocol
Adds the ability to upload batch history records.
Teledyne CA Protocol
Adds the ability to retrieve a specific bit address and width from Analog, Greycode and Digital items.
Totalflow Protocol
Adds 'TIMESTAMP' and 'TIMESTAMPUTC' modifiers for app.array.index items to provide date/time in local and UTC timestamp format.
Publishing
Adds the ability to use tokens in the form $$Fieldn$$ (where 'n' represents the one-based index of a field in a history record) in a path or file name of the CSV publisher.
Adds non-configuration and DPTransducerRangeLow events for CFX7/CFX8.
Improves error messages generated by the PGAS XML publisher by providing more detail in the logged message.
Provides an option to adjust the timestamp of gas quality records published through the PGAS XML output object.
Server
Adds new security options to control access to ACM from the desktop configuration program and from the mobile app. This also includes an option to control whether administrator accounts have access to ACM. Note that with these new settings, it is possible to leave the server in a state where no one has permission to change any configuration, or even access the server.
Server MonitorAdds the ability to run individual SQL scripts via the ACM Monitor Database Wizard.
Adds the ability to save a custom database connection setting in the ACM Monitor.
TCP Listen Connection
Adds a new option "Delay polling on same connection" to the TCP Listen connection to delay polling a device if it uses the same connection as another device that is currently polling, even if there is a session available. This will prevent multiple conflicting connections to the same IP address and Port.
Adds a property to the TCP Listen connection object to configure an initial data timeout after an incoming socket connection is accepted.
Issues Addressed
Archive Management
Adds validation to the Missing Hourly and Daily calculation for Archive Management in order to handle a scenario in which the same meter is being used on multiple devices
Client Application
Modifies the Alias Group validation to prevent empty alias and item names from being saved.
Modifies the ACM security login to accept "." in the user object's domain name.
Configuration Database
Corrects an issue that could cause replication to fail if the tblMeterRecordsHistory is being replicated.
General
Corrects an issue that prevented items in the $Perf object from being validated and added from OPC clients.
Modifies the client application to display the "Out of Sync" message on an open form if that object was modified during an import.
OPC Client
Modifies the OPC test client to allow for a value to be written to an item more than once, even if the value didn't change.
Standardizes the initialization of writeable Extended items to "Good" quality.
BSAP Protocol
Adds support for user strings and user doubles to GC write.
DF1 Protocol
In situations where two responses are in the buffer at the same time, the driver will move over the first packet and validate the second one as the response to process.
DNP3 Protocol
Converts new DNP3 FBx unit types for use in the ACM publishers.
Adds FBx to ACM unit mappings that were left out of previous updates.
History fields may be published with new unit types.
Flow Automation Protocol
Corrects a GC Write issue in the Williams Gas Load that could cause the GC Write to fail after reading partial GC items.
FlowX Protocol
Adds validation to the Flow-X History Map to prevent duplicate Field Identifiers from being used.
Hex Repeater Protocol
Corrects an issue that prevented writes to device configuration items unless the ACM license has the 'history' feature enabled.
ROC Protocol
Adds stricter validation on ROC T.P:L items.
Corrects an issue where external mapping with an EFM ID of UNKNOWN produced unexpected results.
Corrects an issue where an external mapping with the ACM field identifier "Unknown" could cause incorrect results in published history records.
Corrects an issue where configuring a "First Collection Count" of 0 caused no records to be retrieved. Instead, a limit of 0 is now treated as if no limit is defined and all available records will be collected.
Corrects an issue where some history point mappings could lead to sporadic partial history records.
Romet-Adem Protocol
Corrects an issue in referenced object text boxes that caused names to be truncated in the display.
Publishing
Adds Flow Time to the CFX8 batch records.
Server
Adds the ability to delete history on a hourly interval. This option is found in the Manage Database wizard of ACM Monitor.
Corrects an issue that prevented items in the "Alias" branch from displaying correctly when browsing ACM from Ignition.
Server Monitor
Improves the description for the FlowCal Area Index property.
TCP Listen Connection
Prevents a TCPIP Listen connection attempt from lasting more than two minutes.
TCPIP Connection
Prevents a TCPIP connection attempt from lasting more than two minutes.