GE SRTP
- 1 Introduction
- 2 Tabs
- 2.1 General
- 2.2 Advanced
- 2.3 Comm Stats
Introduction
A driver for GE PLCs that support the SRTP protocol, full ACM writeup here: https://autosoln.atlassian.net/wiki/x/LYRsD
Tabs
General
Property | Description |
|---|---|
Name | The name of this GE SRTP Protocol object. The name is used when data is published. |
Description | A note field for information about the device |
Enabled | If checked, Edge ACM will poll this device when running |
Bytes Per Reference Request | Default = 2048. This setting restricts the maximum number of bytes per message during reference (‘%’) value reads. If you request more bytes than specified here then the request will be split into multiple poll messages. The only reason to adjust this setting is if you are getting consistent timeouts on a slow connection due to message size. |
Symbolic Variable Metadata Request Per Message | Default = 100. Max number of symbolic variable metadata items to resolve per message. |
Symbolic Variable Value Request Bytes Per Message | Default = 1024. Max number of symbolic variable value bytes to request per message. |
Symbolic Variable Value Request Count Per Message | Default = 500. Max count of symbolic variable values to request per message. |
Tag Groups | The Tag Groups that are associated with this device. Edge ACM will only poll this device for the tags in the groups selected here |
Connection Settings | The object that contains the connection settings Edge ACM will use to connect to the End Device |
Folder | The parent folder for this item |
Advanced
It is recommended that the advanced values not be changed unless advised by technical support to do so.
Property | Description |
|---|---|
Destination Node | Default = 3600. |
Symbolic Variable Pathname | Default = Not selected. This setting is only used when Override Retrieved Symbolic Variable Pathname with Manual Setting in Protocol Options is checked. |
Override Retrieved Symbolic Variable Pathname with Manual Setting | Default = Not selected. Selecting this will use the entry in the Symbolic Variable Pathname property for the protocol’s symbolic variable handle and metadata read messages. |
Use Verbose Logging | Default = Not selected. Selecting this will turn on more verbose logging during symbolic variable reads. This is useful when needing more information to diagnose issues with polling for symbolic variables and other similar situations. |
Comm Stats
See the Comm Stats entry on the Common Tabs page: Common Tabs | Comm Stats
For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.