Out of Maintenance Software Release Contents

Out of Maintenance Software Release Contents

Information about ACM Security can be found:  AUTOSOL Security Center

Out of Maintenance Releases

Release

Category

Type

Text

Affects Published Output

Addresses Security Vulnerability

Release

Category

Type

Text

Affects Published Output

Addresses Security Vulnerability

8.2.1

Issue

ACM Server

Corrects a property load error that can occur when processes ACM relies upon aren't available.

 

 

8.2.1

Issue

Client Application

Corrects the tool tip message for the Details tab User01 property.

 

 

8.2.1

Issue

Client Application

Corrects the checkbox list initial focus issue on multiple tabbed pages

 

 

8.2.1

Issue

Client Application

The date-time parameters in reports will now correctly display the saved date and time when editing a scheduled report.

 

 

8.2.1

Issue

Client Application

Corrects an issue that prevented using the "Edit Multiple" feature to edit the Protocol Options on multiple New Honeywell Mercury devices.

 

 

8.2.1

Issue

Client Application

Removes erroneous log messages that were displayed when writing to an item with "ReadUserOnly" disabled.

 

 

8.2.1

Issue

Configuration Database

Improves performance of the Archive Management/Gap Detection Process.

 

 

8.2.1

Issue

Configuration Database

Improves performance of resetting a publisher, both with and without a filter.  Note:  Will be more efficient if appropriate indexes exist on the tables.  Run the manual update script to create missing indexes.

 

 

8.2.1

Issue

Configuration Database

Improves overall publishing performance. Note:  Will be more efficient if appropriate indexes exist on the tables.  Run the manual update script to create missing indexes.

 

 

8.2.1

Issue

Configuration Database

Adds three reports for verifying data and schema integrity. 
-The "Data Integrity Report" returns information regarding potential errors in the configuration.

-The "Frequent alarm and event Report" returns information regarding meters with alarms and events above a given quantity .
-The "Database Schema Integrity Report" returns details about the production schema that does not match the installed ACM version such as missing or mismatched indexes and triggers.

 

 

8.2.1

Issue

Configuration Database

Adds a table to the ACM Database for keeping track of database version history.

 

 

8.2.1

Issue

Configuration Database

Provides a script to create all expected but missing indexes on ACM tables.

 

 

8.2.1

Issue

Configuration Database

Modifies the stored procedure that is responsible for deleting archive records to make it more efficient.

 

 

8.2.1

Issue

Connections: Base Connection

Increases the Connection Settings Reply Timeout maximum value from two minutes to three minutes.

 

 

8.2.1

Issue

Connections: Serial Connection

Corrects an issue that prevented saving configuration changes in Serial Ports.

 

 

8.2.1

Issue

Connections: TCP Listen Connection

Corrects a crash in connection modules that occurred during poll interruption.

 

 

8.2.1

Issue

GC Write Service

Corrects an issue to prevent GC Write Requests from getting stuck after 32,767 retries when using "slow mode".

 

 

8.2.1

Issue

General

Corrects the OPC item ->Server/CfgCount value update when multiple ACMConfig Clients are connected.

 

 

8.2.1

Issue

General

Corrects an issue that allowed Async Writes from an OPC client when they should have been blocked.

 

 

8.2.1

Issue

General

Corrects an issue that could cause the initial OPC refresh to fail when used by a managed language client.

 

 

8.2.1

Issue

Logging

Corrects a crash in asiLOGSERVER service.

 

 

8.2.1

Issue

Protocols: Benchmark Protocol

Corrects an issue that caused asiData to hang when uploading history from a Benchmark device if the server did not have DST setup.

 

 

8.2.1

Issue

Protocols: ControlLogix Protocol

Adds a new option to "Invalidate read items on Forward Open failures". When selected, the driver will Invalidate read items on Forward Open connection errors that are non-recoverable, resulting in no poll messages with item value updates during that poll cycle attempt. Improved logging details for Forward Open connection errors.

 

 

8.2.1

Issue

Protocols: ControlLogix Protocol

Lowers the Timeout Multiplier for CIP connections to help avoid running out of connection resources during rapid polling schedules.

 

 

8.2.1

Issue

Protocols: ControlLogix Protocol

Corrects an issue with Bit offsets for INT data types that stopped getting read updates after being written to with the Verify Writes option enabled.

 

 

8.2.1

Issue

Protocols: ControlLogix Protocol

Corrects an issue where invalid messages present in the buffer could cause validation logic to hang up the polling engine.

 

 

8.2.1

Issue

Protocols: Enron Modbus Protocol

Corrects an issue where EFM configuration requests were being built individually, even when poll block was enabled and registers were within range.  Now these will be built as combined messages for Enron, Kinder Morgan, Prosoft, Scadapack and Scanner1150 Modbus protocol.

 

 

8.2.1

Issue

Protocols: Flow Automation Protocol

Modifies the driver to output the correct meter configuration record for Coastal Flow device type.

 

 

8.2.1

Issue

Protocols: FlowX Protocol

Provides missing device destination IP and Port as part of requested message to meet possible firewall rules.

 

 

8.2.1

Issue

Protocols: FlowX Protocol

Corrects an issue that could prevent history collection when not using an alarm map.

 

 

8.2.1

Issue

Protocols: Honeywell - Mercury Protocol

Corrects an issue that prevented items from being successfully added during a restart of ACM if the device firmware did not support the new RG command.

 

 

8.2.1

Issue

Protocols: Honeywell - Mercury Protocol

Corrects an issue that prevented messages from being consolidated after items were removed.

 

 

8.2.1

Issue

Protocols: Honeywell - Mercury Protocol

Corrects an issue when writing TS, GCWrite and NextCallinSchedule that prevented the write message from using the configured access code.

 

 

8.2.1

Issue

Protocols: Honeywell - Mercury Protocol

Modifies the driver to correctly handle an error returned during an ACK or NAK request so that a poll cycle retry will be triggered.

 

 

8.2.1

Issue

Protocols: Honeywell - Mercury Protocol

Modifies several protocols such as the new Mercury protocol and Omni protocol to update meter record time stamp after recollection. *Effect On Published Output: Meter configuration records will be republished after re-collection without requiring a restart of asiData.

X

 

8.2.1

Issue

Protocols: Modbus Protocol

Corrects an error that prevented using the modbus "block read" item.

 

 

8.2.1

Issue

Protocols: ROC Protocol

Corrects a logger warning message which resulted when some ROC configurations published meter configuration information.

 

 

8.2.1

Issue

Protocols: Scancom Protocol

Corrects an issue with Demand GC message not correctly building for Adept 4.0 message format.

 

 

8.2.1

Issue

Protocols: Scancom Protocol

Corrects an issue with variable length strings in EFM records that resulted in reading incorrect characters from the buffer beyond the record. *Effect On Published Output: Invalid characters from the buffer will no longer be output in a variety of record types.

X

 

8.2.1

Issue

Protocols: Scancom Protocol

Corrects OPC validation of hardware items so that they will will not be added if parameter and slot are not entered correctly.

 

 

8.2.1

Issue

Protocols: Scancom Protocol

Modifies the driver so that items not updated due to an error with an item id in a read are now marked as invalid.

 

 

8.2.1

Issue

Protocols: Siemens S7 Protocol

Adds configuration settings to directly control TSAP values on S7-200 model connections.

 

 

8.2.1

Issue

Protocols: Totalflow Protocol

Corrects the log messages displayed when executing the "Retrieve Meter config during next history poll" and "Reset History (LogPeriod/Daily/Event) Pointer" commands.

 

 

8.2.1

Issue

Protocols: Totalflow Protocol

Corrects an issue in the meter configuration record where multiple sets of duplicated fields were output when using the Number of Days history collection option. *Effect On Published Output: Meter Configuration records will no longer contain multiple duplicate fields.

X

 

8.2.1

Issue

Publishing

Corrects an issue that could cause the FlowCal Transaction Queue publisher to insert a zero into a GC or history field when the field has no value. *Effect On Published Output: Empty GC and history record fields will now be blank instead of displaying a 0 in the Flowcal Transaction Queue.

X

 

8.2.1

Issue

Configuration Database

Modifies the meter historization process to run in a stored procedure instead of a trigger to prevent issues with replication and clustering.

 

 

8.2.1

Issue

Configuration Database

Modifies the meter historization process to only keep unique meter FieldData

 

 

8.2.1

Issue

Honeywell - Mercury Protocol

Corrects an issue that resulted in response packet noise byte characters being included in the CRC calculation.

 

 

8.2.1

Issue

Honeywell - Mercury Protocol

Corrects an issue that could result in a failed EFM upload completing with a Successful Poll result.

 

 

8.2

Archive Management

Issue

Adds validation to the Missing Hourly and Daily calculation for Archive Management to handle a scenario in which the same meter is being used on multiple devices

 

 

8.2

asiDATA

Issue

Corrects an issue that prevented items in the $Perf object from being validated and added from OPC clients.

 

 

8.2

Base Protocol

Feature

Adds the device detail tab fields as OPC Items.

 

 

8.2

BSAP Protocol

Feature

Adds the ability for a user to separately configure whether Serial or Ethernet protocol is used on the primary and/or secondary connections.

 

 

8.2

BSAP Protocol

Feature

Adds support for array items to meter configuration polling.

 

 

8.2

BSAP Protocol

Feature

Adds a configuration item token number to each meter run.  This number will be used to replace a token in the items for the meter configuration reads and GC writes, so that a single Meter Configuration or Gas Chromatograph object can be used for multiple meter runs.

 

 

8.2

BSAP Protocol

Issue

Adds support for user strings and user doubles to GC write.

 

 

8.2

Client Application

Issue

For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.