Out of Maintenance Software Release Contents

Information about ACM Security can be found:  AUTOSOL Security Center

Out of Maintenance Releases


Release

Category

Type

Text

Affects Published OutputAddresses Security Vulnerability
8.2Archive ManagementIssueAdds validation to the Missing Hourly and Daily calculation for Archive Management to handle a scenario in which the same meter is being used on multiple devices

8.2asiDATAIssueCorrects an issue that prevented items in the $Perf object from being validated and added from OPC clients.

8.2Base ProtocolFeatureAdds the device detail tab fields as OPC Items.

8.2BSAP ProtocolFeatureAdds the ability for a user to separately configure whether Serial or Ethernet protocol is used on the primary and/or secondary connections.

8.2BSAP ProtocolFeatureAdds support for array items to meter configuration polling.

8.2BSAP ProtocolFeatureAdds a configuration item token number to each meter run.  This number will be used to replace a token in the items for the meter configuration reads and GC writes, so that a single Meter Configuration or Gas Chromatograph object can be used for multiple meter runs.

8.2BSAP ProtocolIssueAdds support for user strings and user doubles to GC write.

8.2Client ApplicationIssueModifies the ACM security login to accept ".\" in the user object's domain name.

8.2Client ApplicationIssueCorrects error that occurs when changing the ROC Max Message Length property using the multi editor.

8.2Client ApplicationIssueModifies the Alias Group validation to prevent empty alias and item names from being saved.

8.2Client ApplicationIssueModifies the Alias Group validation to prevent duplicate alias names.

8.2Configuration DatabaseIssueCorrects an issue that could cause replication to fail if the tblMeterRecordsHistory is being replicated.

8.2DF1 ProtocolIssueIn situations where two responses are in the buffer at the same time, the driver will move over the first packet and validate the second one as the response to process.

8.2DNP3 ProtocolFeatureAdds support for new objects, parameters, measurements, and units in Emerson FBx firmware release 02.07.00.80. *Effect on published output: Corrects viscosity unit name from pound-feet per second (wrong) to pounds mass per foot-second (right according to CFX5 documentation), changes DPCalibrationRangeHigh to match DPCalibrationLow, and fixes unit ID issue with ENUM16 and BIN* data types.

8.2DNP3 ProtocolFeatureAdds support for new objects, parameters, measurements, and units in Emerson FBx firmware release 02.05.01.10.

X


8.2DNP3 ProtocolIssueAdds FBx to ACM unit mappings that were left out of previous updates. *Effect on published output: History fields may be published with new unit types.

8.2DNP3 ProtocolFeatureAdds support for new objects, parameters, measurements, and units in Emerson FBx firmware release 02.04.01.09.

8.2DNP3 ProtocolIssueConverts new DNP3 FBx unit types for use in the ACM publishers.

8.2DNP3 ProtocolFeatureAdds a rule option in the Meter Configuration object for yes/no fields and RelativeDensitySaturationCondition. Makes FactorFwv and FwvFactorUsed fields interchangeable. *Effect on published output: When a Meter Configuration object (the Advanced Configuration assigned to the Meter object) is used to publish meter configuration data, the fields below now use predefined constants for the "Constant" and "Rule" options.  For the CSV publisher, that means that these values will be published as the text strings "Yes"/"No" (or "Wet"/"Dry"/"AsDelivered" for RelativeDensitySaturationCondition) if translation is used, and as numeric codes if translation is not used.  For the XML publisher, all of the fields below will be now published within the <Common> node, rather than the <Extended> node as some of them were before: FlowingPressureEffectEnabled, Live Analysis, Live BTU, Live Gravity, Live Temperature, HasDefaultTemperature, UseRTD, FwvFactorUsed, FwvsFactorUsed, HasRTD, TemperatureCompensated, PressureCompensated, FactorFa, FactorFb, FactorFg, FactorFpv, FactorFr, FactorFt, FactorFwv, FactorY, RelativeDensitySaturationCondition

8.2Flow Automation ProtocolFeatureAdds history collection support for the Flow Automation Williams Gas load. *Effect on published output: The CFX publisher will now show valid data for GC data in the meter configuration section where previously it was invalid.

8.2Flow Automation ProtocolFeatureAdds read and write item support for function types Plunger Lift (config and instantaneous) and Drip Control for Flow Automation devices with the Coastal Flow load.

8.2Flow Automation ProtocolIssueCorrects a GC Write issue in the Williams Gas Load that could cause the GC Write to fail after reading partial GC items.

8.2FlowX ProtocolFeatureAdds a new command that allows for copying an existing tag file from a configured device. 

8.2FlowX ProtocolIssueAdds validation to the Flow-X History Map to prevent duplicate Field Identifiers from being used.

8.2GC Write ServiceFeatureAdds support for a comma separated list to be used as the Area ID in queries against the Flowcal database for GC Writes. This allows multiple Areas to use the same ACM Server for GC Writes.

8.2Hex Repeater ProtocolIssueCorrects an issue that prevented writes to device configuration items unless the ACM license has the 'history' feature enabled.

8.2LoggingFeatureAdds the assembly version number to the source column in the Log Viewer.

8.2Micro MP3 ProtocolIssueAdds support for Dynamic Flow Computer's MicroMP3 Liquid Flow Computer using the Modbus/MicroMP3 protocol.  - MicroMP3 supports both the truck ticket mode and the full six meter flow computer mode.  - MicroMP3 provides the ability to retrieve and publish daily and monthly batch report records.  - MicroMP3 allows for time synchronization. *Effect on published output: This release adds support for Dynamic Flow Computer's MicroMP3 Liquid Flow Computer using the Modbus/MicroMP3 protocol.

X


8.2OPC ClientIssueModifies the OPC test client to allow for a value to be written to an item more than once, even if the value didn't change. 

8.2OPC ClientIssueStandardizes the initialization of writeable Extended items to "Good" quality.

8.2PublishingFeatureAdds non-configuration and DPTransducerRangeLow events for CFX7/CFX8.  *Effect on published output: Some events that were not previously published as CFX events now will be.

8.2PublishingFeatureImproves error messages generated by the PGAS XML publisher by providing more detail in the logged message.

8.2PublishingIssueAdds Flow Time to the CFX8 batch records.  *Effect on published output: Flow Time will now be included in CFX8 batch records. 

X


8.2PublishingFeatureAdds the ability to use tokens in the form $$Fieldn$$ (where 'n' represents the one-based index of a field in a history record) in a path or file name of the CSV publisher. *Effect on published output: When the new token is used in a path or file name of the CSV publisher, the CSV output will be split into multiple files and/or folders according to the field value.

8.2PublishingFeatureProvides an option to adjust the timestamp of gas quality records published through the PGAS XML output object. *Effect on published output: The timestamp of gas quality records will be published according to the PGAS XML setting.

X


8.2PublishingIssueAdds the ability to use the syntax "Name"="Value" in the CSV publisher field collection. The resulting published file will have the fixed value "Value" in every row of column "Name". *Effect on published output: When the syntax "Name"="Value" is used in the CSV publisher field collection, the resulting published file will have the fixed value "Value" in every row of column "Name".

8.2ROC ProtocolFeatureAdds more units for ROC meter configuration such as differential pressure units, uncorrected volume units to the CFX Output. *Effect on published output: For ROC meter configuration, more units (such as differential pressure units, uncorrected volume units) will be output.

8.2ROC ProtocolIssueCorrects an issue where external mapping with an EFM ID of UNKNOWN produced unexpected results. *Effect on published output: Corrects an issue where an external mapping with the ACM field identifier "Unknown" could cause incorrect results in published history records.

X


8.2ROC ProtocolFeatureAdds a new option "Combine data from all segments into the same archive records" to combine a meter's data from different segments into the same record. *Effect on published output: If the new option "Combine data from all segments into the same archive records" is selected and the user has a meter mapped with fields in different segments, then the fields will be combined into the same record.

8.2ROC ProtocolIssueCorrects an issue where some history point mappings could lead to sporadic partial history records.  *Effect on published output: This corrects an issue where some history point mappings can lead to sporadic partial history records. 

8.2ROC ProtocolIssueCorrects an issue where configuring a "First Collection Count" of 0 caused no records to be retrieved.  Instead, a limit of 0 is now treated as if no limit is defined and all available records will be collected. *Effect on published output: When the archive limit is set to zero, all records will be returned.

X


8.2ROC ProtocolFeatureAdds the ability to set a ROC device date/time to any value required via new Extended OPC tag ClockSet.

X


8.2Romet-Adem ProtocolIssueCorrects an issue in referenced object text boxes that caused names to be truncated in the display. 

X


8.2SCADAPack ProtocolIssueAdds the ability to publish batch fields in audit records. *Effect on published output: When batch information is included in audit trail records, columns will be added to the CSV output.  When batch record user data fields are included in audit trail records or batch records for liquid type runs, columns will be added to the CSV report and Batch Custom Records will be added to the CFX report.

X


8.2SCADAPack ProtocolFeatureAdds the ability to upload batch history records. *Effect on published output: Historical batch records can now be published.

8.2ServerIssueAdds the ability to delete history on a hourly interval.  This option is found in the Manage Database wizard of ACM Monitor. 

X


8.2ServerIssueAdds new security options to control access to ACM from the desktop configuration program and from the mobile app. This also includes an option to control whether administrator accounts have access to ACM. Note that with these new settings, it is possible to leave the server in a state where no one has permission to change any configuration, or even access the server.

X


8.2ServerIssueCorrects an issue that prevented items in the "Alias" branch from displaying correctly when browsing ACM from Ignition.

X


8.2Server MonitorFeatureAdds the ability to run individual SQL scripts via the ACM Monitor Database Wizard.

X


8.2Server MonitorFeatureAdds the ability to save a custom database connection setting in the ACM Monitor.

X


8.2Server Object ModelIssueModifies the client application to display the "Out of Sync" message on an open form if that object was modified during an import.

8.2TCP Listen ConnectionFeatureAdds a new option "Delay polling on same connection" to the TCP Listen connection to delay polling a device if it uses the same connection as another device that is currently polling, even if there is a session available. This will prevent multiple conflicting connections to the same IP address and Port.

8.2TCP Listen ConnectionFeatureAdds a property to the TCP Listen connection object to configure an initial data timeout after an incoming socket connection is accepted.

8.2TCP Listen ConnectionIssuePrevents a TCPIP Listen connection attempt from lasting more than two minutes.

8.2TCPIP ConnectionIssuePrevents a TCPIP connection attempt from lasting more than two minutes.

X


8.2Teledyne CA ProtocolFeatureAdds the ability to retrieve a specific bit address and width from Analog, Greycode and Digital items.

8.2Totalflow ProtocolFeatureAdds 'TIMESTAMP' and 'TIMESTAMPUTC' modifiers for app.array.index items to provide date/time in local and UTC timestamp format.

X


ACM 8.1

Protocols: Totalflow Protocol

Issue

Corrects an issue that caused that the "Request 3 days of history when 2 days history is needed" option to be ignored



ACM 8.1

Protocols: Totalflow Protocol

Issue

Made a modification to stop history collection if meter configuration retrieval failed and no meter configuration data has been retrieved previously.  If meter configuration data has previously been retrieved the history collection will continue.



ACM 8.1

Protocols: Totalflow Protocol

Issue

Modified the initial OPC quality of MoveEvent to be good to match the other "Move" items.



ACM 8.1

Publishing

Feature

Adds mapping for SP Transducer Range High to SP_HIGH_RANGE in the PGASXML publisher. *Effect on published output: When an EFM record contains SP Transducer Range High, SP_HIGH_RANGE is assigned and present in the output file.

X


ACM 8.1

Publishing

Issue

Corrects an issue in the EFM Database that caused duplicate records to be added. *Effect on published output: The EFM Database will update all existing meter records if 1 or more meter records are found instead of adding new meter records.

X


ACM 8.1

Publishing

Issue

Modified the PGASXML history type to convert the energy units that do not match MMBTU, DTH or GJ to DTH. *Effect on published output: When an unsupported energy unit is submitted with a PGAS record, the value and unit will be converted to DTH.

X


ACM 8.1

Server Monitor

Issue

Corrects an issue that prevented the display of Meter Resolution Mode options in the Gas Analysis Write File Service section of ACM Monitor properties.



ACM 8.0.1

ACM Server

Issue

Corrects an issue that occasionally caused comm stats to show values greater than 100 percent. *Effect on published output: Reports that may have shown comm stats greater than 100 percent should now show the correct values.

X


ACM 8.0.1

OPC Items

Issue

Corrects an issue that caused the 'ItemCount' OPC item value to lag behind the actual count of items.



ACM 8.0.1

Protocols: FlowX Protocol

Issue

Prevent an invalid meter record from being stored in the meter history table, when generated due to misconfigured station meters on a device.



ACM 8.0.1

Protocols: Honeywell - Mercury Protocol

Feature

Adds OPC items "LastPollD" and "LastPollN" for compatibility with AES.



ACM 8.0.1

Protocols: Honeywell - Mercury Protocol

Feature

Adds support in the new Honeywell Mercury protocol for fixed temperature and pressure in audit records.



ACM 8.0.1

Protocols: Honeywell - Mercury Protocol

Issue

Corrects issue in the new Honeywell Mercury protocol that could cause the unit types for pressure and volume to be published incorrectly for an EC350 device. *Effect on published output: Unit type fields for pressure and volume now have the correct value for EC350.

X


ACM 8.0.1

Protocols: Honeywell - Mercury Protocol

Issue

Corrects an issue that could cause EFM audit records to be skipped if comm failure occurred during upload.



ACM 8.0.1

Protocols: Mercury Protocol

Issue

Corrects issue that prevented demand to be issued using OPC item.



ACM 8.0.1

Protocols: Mercury Protocol

Issue

Corrects an issue in the new Honeywell Mercury protocol that caused communication timeout if an item's return data was an empty string.



ACM 8.0.1

Protocols: Mercury Protocol

Issue

Corrects issue in new Honeywell Mercury protocol that caused incorrect parsing of D1 audit record if units field was empty. *Effect on published output: Published audit data will have correct values for 350 series.

X


ACM 8.0.1

Protocols: Mercury Protocol

Issue

Corrects the call-in message sequence in the old Honeywell Mercury protocol to correctly ACK call-ins before proceeding other requests.



ACM 8.0.1

Protocols: Mercury Protocol

Issue

Corrects issue in new Honeywell Mercury protocol that caused incorrect values to be published for a EC350 meter's K-Factor. *Effect on published output: Published Meter Configuration K-Factor values for EC350 are now correct.  K-Factor units are now published. This will add a new column to a CSV report.

X


ACM 8.0.1

Protocols: Mercury Protocol

Issue

Corrects an issue in the new Honeywell Mercury protocol that caused the gas quality configuration value for nPentane to be published as nHeptane. *Effect on published output: Meter gas quality configuration values nPentane and nHeptane will now have correct values.

X


ACM 8.0.1

Protocols: Mercury Protocol

Issue

Corrects an issue in the new Honeywell Mercury protocol that caused the meter configuration static pressure units to be published multiple times. *Effect on published output: Static pressure units will only be published once. This will reduce the number of columns in a CSV meter configuration report.

X


ACM 8.0.1

Protocols: Mercury Protocol

Issue

Adds support for additional Live Read items to the new Honeywell Mercury protocol.



ACM 8.0.1

Protocols: Mercury Protocol

Issue

Implemented GC Write Service support in the new Honeywell Mercury protocol.



ACM 8.0.1

Protocols: ROC Protocol

Issue

Corrects issue in LastHourlyRecord, LastDailyRecord, LastEventRecord and LastAlarmRecord when items are not updated after successful history collection. Extended items to include "/meter" for each meter result. If no /meter is specified by default it outputs first run result.



ACM 8.0.1

Protocols: Romet-Adem Protocol

Issue

Corrects an issue in the ROMET AdEM protocol that caused the TimeSync item to appear in  OPC browse list twice. Corrects an issue in the ROMET AdEM protocol that prevented the RequestMeterConfig item from appearing in the OPC browse list.



ACM 8.0.1

Protocols: Romet-Adem Protocol

Issue

Corrects an issue in the new Honeywell Mercury protocol that caused the log on message to be sent multiple times when using a Continuous Scan cycle.



ACM 8.0.1

Protocols: Romet-Adem Protocol

Issue

Corrects an issue in the new Honeywell Mercury protocol that could cause the RetrieveHistory item to maintain a value of negative one (-1).  Corrects an issue in the new Honeywell Mercury protocol that prevented the TimeSync item's value from updating.  Corrects an issue in the Romet-Adem protocol that could cause the RetrieveHistory item to maintain a value of negative one (-1).  Corrects an issue in the Romet-Adem protocol that prevented the TimeSync item's value from updating.



ACM 8.0.1

Protocols: Teledyne CA Protocol

Issue

Adds validation to the Greycode conversion.



ACM 8.0.1

Publishing

Issue

Corrects to CFX publishers so ACM correctly publishes the Differential Pressure or Pulse value from a history record based on the meter type and the presence of either the Differential Pressure value, the Pulse value, neither, or both. *Effect on published output: CFX publishers will determine the value to store in the DP or Pulse field of history records based on the meter type and the presence of DP or Pulse data.

X


ACM 8.0

ACM Server

Feature

Adds communication statistics items for each port within the TCPPool port object. Note: These components must be applied as part of a full ACM update.  This feature changes the method used by ACM components to track communication statistics data. It affects all protocol modules, all connection port modules, the main polling engine, and the database. They should not be applied as a single module update.



ACM 8.0

ACM Server

Feature

Improved security configuration to allow authorized users to: - Assign permissions for Create/Update/Delete operations on all objects, objects of a specific type, or specific properties on objects of specific types. - Assign permissions for command execution on all objects, objects of a specific type, or specific commands on objects of specific types.



ACM 8.0

ACM Server

Feature

Adds "Abort Current Task" and "Dump Item List" as commands available to each protocol.  These commands were previously only available via an OPC Client.



ACM 8.0

ACM Server

Feature

Adds a new option to control how often ACM updates values for items subscribed through the custom Item Server interface. Items can now be updated only when their value or quality changes, or they can be updated on every poll.  This new option was added to the "Server" tab of the $Server object and is labeled "Item Update Frequency".



ACM 8.0

ACM Server

Issue

Corrects an issue that caused asiDATA to send back an unscaled value for an item with scaling flags when an OPC client did a synchronous read request before ACM had polled the item.



ACM 8.0

Archive Management

Issue

Corrects an issue in the Archive Manager causing ACM to close due to an Application Hang error.



ACM 8.0

Archive Management

Issue

Modified the Archive Management process to display the correct type of periodic history based on the "Type" selection of Hourly or Daily.



ACM 8.0

Archive Management

Issue

Resolved an issue where the toolbar on the Archive Detail screen was not functioning.



ACM 8.0

Archive Management

Issue

Updated the Archive Management tab buttons and tool tip labels to better describe the form functions.   Added a refresh button to the Archive Management grid to refresh the data in the grid.



ACM 8.0

Client Application

Feature

Adds an option to the Dashboard "View" drop-down to select no active view, which cancels item subscriptions.



ACM 8.0

Client Application

Feature

Adds an option to the User Preferences to use the default datetime format or to establish a custom datetime format.  All datetime tags shown within the client for the logged in user will follow this setting.



ACM 8.0

Client Application

Feature

Adds a button to the Log Viewer to mimic the behavior of the keyboard short-cut Ctrl+M to add a mark to the log.



ACM 8.0

Client Application

Feature

Adds the sub-option "Shutdown even when auto-poll enabled" under "Auto-Shutdown" to the UI form of the Server Object.  This was previously only visible in the property grid view.



ACM 8.0

Client Application

Issue

Corrects an issue in the Record Collection "Add-Multi" form that allowed values greater than the maximum to be entered.



ACM 8.0

Client Application

Issue

Corrects issues that caused unexpected results when pasting into a Multi-editor grid.



ACM 8.0

Client Application

Issue

Updated messages when importing ACM configuration data to make it clear when a rename is related to leading or trailing spaces having been deleted.



ACM 8.0

Client Application

Issue

Corrects an error that prevented the selection of RTU Configuration files located on a different drive than where ACM is installed.



ACM 8.0

Client Application

Issue

Corrects an issue that displayed many pop-up error messages when the connection to the ACM Server was lost.



ACM 8.0

Client Application

Issue

Adds platform version details to the Server Information form.



ACM 8.0

Client Application

Issue

Update verbiage on the Reconnect dialog to make the options clearer.  This dialog appears if the connection to the ACM Server is lost.



ACM 8.0

Client Application

Issue

Corrects the right-click action on multi-edit grids for unit fields so that all highlighted fields will be updated.



ACM 8.0

Client Application

Issue

Corrects an issue in the Archive Collection and Meter Run forms that made it appear object names were being truncated.



ACM 8.0

Client Application

Issue

Corrects an issue that caused the application to lose focus when turning off Tabular View in a record collection window.



ACM 8.0

Client Application

Issue

Allow Server Information dialog to detect greater than 4.0 versions of .NET



ACM 8.0

Configuration Database

Issue

Modified the history deletion process to keep the correct number of periodic records and to improve the speed at which records are deleted.



ACM 8.0

Configuration Database

Issue

The Safe Mode option was updated to use the Microsoft ACE OLEDB 12.0 database driver. This driver is now required for those users who enable the Safe Mode option. It is a free download from Microsoft here: https://www.microsoft.com/en-us/download/details.aspx?id=13255



ACM 8.0

Configuration Database

Issue

Corrects an issue in the Bulk Manager that caused staging tables to grow continuously with unprocessed records after timeouts.



ACM 8.0

Connection: Base Connection

Issue

Modified all port types to enforce the maximum allowed Transmit Delay of 60 seconds to prevent a very long delay period from blocking polling on the port.



ACM 8.0

Connection: TCP Listen Connection

Issue

Adds a check to Serial, TCP/IP, TCPPool and TCPListen port types to monitor transmit delay time and ensure it is limited to the 60 second maximum setting.



7.1.306

ACM Server

Feature

Adds new option for persistent data troubleshooting logging.Corrects an issue that could store the wrong user name with configuration change history.



7.1.306

ACM Server

Feature

Adds new reports for Archive Daily & Hourly Summary.



7.1.306

ACM Server

Feature

Adds optional troubleshooting logging.



7.1.306

ACM Server

Feature

Adds support for Emerson FBx tunnel command parameter reads and writes for FB3000.



7.1.306

Archive Management

Feature

Adds more granular control over the frequency and time of the gap detection process.



7.1.306

Client Application

Feature

Adds the ability to copy/paste into and out of the Multi-Object Editor.



7.1.306

Connections

Issue

Corrects an issue where the Queue Viewer showed ‘success’ when an I/O write failed.



7.1.306

Connections: TCP Pool

Issue

Improves TCPPool port to try other available modems upon failure of initialization when using 'Release when done'.



7.1.306

Protocols: Base Protocols

Issue

Corrects an issue that could leave the ‘demand’ status ‘true’ after a device was disabled.



7.1.306

Protocols: Base Protocols

Issue

Corrects an issue that could prevent history collection from resuming after a higher priority task interruption.



7.1.306

Protocols: Base Protocols

Issue

Corrects an issue that could result in a driver crash if a session object was invalid.



7.1.306

Protocols: Base Protocols

Issue

Corrects an issue that prevented license information from displaying correctly if the license file had trailing characters. This was an issue with display only, not with the server’s use of the license information.



7.1.306

Protocols: Base Protocols

Issue

Corrects an issue where a poorly configured scheduled report could terminate the report server.



7.1.306

Protocols: ControlLogix Protocol

Issue

Corrects an issue where writes to items of type D3 resulted in communication timeouts during later writes to the same items.



7.1.306

Protocols: ControlLogix Protocol

Issue

Corrects an issue where, in some conditions, user strings were being converted to floating point numbers. *Effect on Published Output: This will change the output of string fields. R4 or R8 device data type conversion to string will remain the same. String device data type conversion to string will remain the same.



7.1.306

Protocols: ControlLogix Protocol

Issue

Corrects an issue where, using the PGAS xml publisher, an incorrect time stamp could occur if more than one publisher published the same meter.



7.1.306

Protocols: ControlLogix Protocol

Issue

Corrects an issue with a DB1 device reading device setup.



7.1.306

Protocols: ControlLogix Protocol

Issue

Corrects an issue with the item used for a Test Communication poll. The item wasn’t supported for all instrument types.



7.1.306

Protocols: ControlLogix Protocol

Issue

Corrects an issue with the OLTP history map to include Mercury EFM IDs for Volume Indexes. This change will populate volume indexes that were missing from the OLTP publisher. Note: Publishing to OLTP output is not supported for Mercury devices with any of the PGAS options enabled in the Mercury protocol setup.



7.1.306

Protocols: FlowX Protocol

Issue

Corrects an issue where the service crashed upon processing a record with null string data.



7.1.306

Protocols: FlowX Protocol

Issue

Corrects an issue where time synchronization priority was using the EFM history priority.



7.1.306

Protocols: FlowX Protocol

Issue

Corrects an issue where using an invalid host name or address in the multi-server search caused an error.



7.1.306

Protocols: FlowX Protocol

Issue

Corrects an issue where writes failed when using unlisted integer tags polled as bit values.



7.1.306

Protocols: Kinder Morgan Modbus Protocol

Feature

Adds an option to skip the ‘sequence number reset check’ for Kinder Morgan devices.



7.1.306

Protocols: Kinder Morgan Modbus Protocol

Feature

Adds capabilities on the multi-record dialog grid-view for add/remove records, and to add multiple records at once.



7.1.306

Protocols: Kinder Morgan Modbus Protocol

Feature

Adds dashboard for current data views.



7.1.306

Protocols: Omni Modbus Protocol

Feature

Adds the flow computer Id (from register 4836) to the collection of meter configuration data output for FLOWCAL CFX formats. *Effect on published output:  This change will add a column for the new flow computer Id value to published outputs that use the Database or CSV publishers and will fill in the Flow Computer ID field in CFX files.



7.1.306

Protocols: ROC Protocol

Feature

Adds an option to not write to E2PROM upon a gas chromatograph write. Some older versions of firmware caused the ROC to restart when this write was done.



7.1.306

Protocols: SCADAPack Protocol

Issue

Corrects an issue where history collection from a liquid meter in a SCADAPack could terminate prematurely if the ‘Leading Timestamp’ was not checked. Collection now works correctly with and without the ‘Leading Timestamp’ option enabled.



7.1.306

Protocols: SCADAPack Protocol

Issue

Corrects an issue where leading or trailing spaces on history map tag names caused errors.



7.1.306

Protocols: SCADAPack Protocol

Issue

Corrects an issue where message responses may not be processed correctly when their list of items changed.



7.1.306

Protocols: SCADAPack Protocol

Issue

Corrects an issue where PGAS xml was not treating specific gravity and relative density the same way.



7.1.306

Protocols: SCADAPack Protocol

Issue

Corrects an issue where right-clicking on a folder and selecting 'Retrieve History From Children' was attempting to retrieve history from non-device objects.



7.1.306

Protocols: SCADAPack Protocol

Issue

Corrects an issue where some of the $System object properties related to persistent data would not save properly.



7.1.306

Protocols: SCADAPack Protocol

Issue

Corrects an issue where tag names were case-sensitive.



7.1.306

Protocols: Totalflow Protocol

Feature

Adds an option to adjust timestamp of trend records when retrieving as trend (not when retrieving for merge to volume history).



7.1.306

Protocols: Totalflow Protocol

Feature

Adds an option to check meter name in remote device against ACM meter object name and stop collection if they don't match.



7.1.306

Protocols: Totalflow Protocol

Feature

Adds an option to publish trend records as periodic history or gas chromatograph history. This option is only available through the property grid view of the device setup (not on the form view).



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects an issue where AGA factor values were being interpreted incorrectly (inverse value) when producing the Yes/No factor string for the Factors field in outputs like CFX.  *Effect on Published Output: This may result in modified output for Totalflow AGA factor values.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects an issue where an incorrect data type was reported for unlisted integer tags polled as bit values.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects an issue where Calculate Average Flowrate field was missing in PFX output.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects an issue where certain fields in PGAS xml such as Flowing Density and Uncorrected Density were not converted correctly if in any format other than double precision.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects an issue where Connection object's 'Quiet Delay' and 'Transmit Delay' were mislabeled.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects an issue where error code ORA-03149 was not detected properly.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects an issue where history collection could loop if the device returned an error/status ‘33’.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects an issue where the driver may not correctly calculate the sequence number for the last available record, resulting in re-collection and a duplicate record.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects an issue where the maximum allowed value for the 'Slow Timeout" property for GC Writes was changed from a previous version and became too limiting.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects an issue with time sync when RBAC security (operator ID and Password) is used.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects issues where re-sizing windows caused control layout problems.



7.1.306

Protocols: Totalflow Protocol

Issue

Corrects various issues that could result in history collection stopping if a time gap was detected or if multiple duplicate records were detected.



7.1.306

Protocols: Totalflow Protocol

Issue

For ROC800L added missing data for EFM fields ending in "IndexEnd".  *Effect on Published Output: This change will add a column for the new Index End value to published outputs that use the Database or CSV publishers and will fill in the Index End field in CFX files.



7.1.306

Protocols: Totalflow Protocol

Issue

Improves history collection logic to allow better handling of invalid records.



7.1.306

Protocols: Totalflow Protocol

Issue

Improves Log Viewer and Queue Viewer so they save configured column widths.



7.1.306

Protocols: Totalflow Protocol

Issue

Improves performance on Archive Management views and queries.



7.1.306

Protocols: Totalflow Protocol

Issue

Improves Totalflow protocol to prevent publishing repeated alarm records when the alarm state hasn't changed.  *Effect on Published Output: This may result in modified output for Totalflow. This change prevents publishing repeated Totalflow alarm records when the alarm state hasn't changed. Also fixes the alarm bits value published as part of the log record.



7.1.306

Publishing

Feature

Adds an option to control the insertion of a quality element from meter configuration data.



7.1.306

Publishing

Feature

Adds an option to convert trailing timestamps to leading for AutoSol EFM Database and XML publishers.



7.1.306

Publishing

Feature

Adds an option to convert trailing timestamps to leading.



7.1.306

Publishing

Feature

Adds an option to create analysis records from volume records in PGAS xml publisher.



7.1.306

Publishing

Feature

Adds an option to create gas quality records from gas component data in meter configuration records.



7.1.306

Publishing

Issue

Improves PGAS processing speed by restructuring the XML content.  *Effect on Published Output: This change will result in a difference in the structure of PGAS XML file.



7.1.306

Publishing

Issue

Modified the PGAS xml publisher to refrain from converting numbers into scientific notation.   *Effect on Published Output: This change will result in a difference in the structure of PGAS XML file.



7.1.306

Publishing

Issue

Moved GQ_PERIODIC records out to their own transaction. *Effect on Published Output: This change will result in a difference in the structure of PGAS XML file.



7.1.306

Publishing

Issue

Moved 'REAL_GRAVITY' in PGAS xml publisher from gas analysis node to the volume node.



7.1.306

Publishing

Issue

Removed enforced timeouts on database updates that could cause update failure.



7.1.306

Publishing

Issue

Writes to I/O items are now combined with other messages of different priority if a continuous scan is in progress. This is enabled for ‘generic’ or basic Protocols: Modbus Protocol only.



7.1.306

Reports

Feature

Adds two new reports for missing daily and missing hourly records.



7.1.306

Reports

Issue

Corrects a crash in the service when logging extra data items which had no extra data.



7.1.306

Reports

Issue

Corrects a history collection issue when using SCADAPack devices with Realflo revisions before 5.20.



7.1.306

Reports

Issue

Corrects an issue that caused history collection looping if an archive object was configured to be its own GC archive.



7.1.306

Reports

Issue

Corrects an issue that could leave an ‘empty’ request message queued while in continuous scan mode if all OPC items were removed.



7.1.302

ACM Server

Feature

Adds an OPC tag to indicate when running in Safe Mode.



7.1.302

ACM Server

Feature

Adds OPC Server item ServerStartTime(local and UTC).



7.1.302

ACM Server

Feature

Adds OPC tags for ServerName and DiskActivity.



7.1.302

ACM Server

Feature

Adds support for /B (Boolean) modifier on Status item.



7.1.302

ACM Server

Feature

Adds support for the new Microsoft OLE DB database connectivity.



7.1.302

ACM Server

Feature

Adds the ability to browser for Alias tags in an OPC client.



7.1.302

ACM Server

Feature

Adds the ability to display last poll times by interval.



7.1.302

ACM Server

Feature

Adds the ability to display last poll times in Julian date format.



7.1.302

ACM Server

Feature

Adds the ability to keep and historize previous meter configurations.



7.1.302

ACM Server

Issue

Corrects a memory leak issue.



7.1.302

ACM Server

Issue

Corrects an issue where asiCONFIGSERVER service could crash.



7.1.302

ACM Server

Issue

Corrects an issue where OPC item $Server.ActiveItemCount was not decrementing when appropriate.



7.1.302

ACM Server

Issue

Corrects an issue where renaming an object while modifying an additional property in the object would fail to modify the additional property.



7.1.302

ACM Server

Issue

Corrects an issue where server level aliasing was not working.



7.1.302

ACM Server

Issue

Corrects an issue where the Change Log was not being updated on object creation.



7.1.302

ACM Server

Issue

Corrects an issue where the item modifier for interval <i*> was not supported for alias items.



7.1.302

ACM Server

Issue

Corrects an issue where the OPC tag MaxDatabaseSize was not always accurate depending upon how the database was set up.



7.1.302

ACM Server

Issue

Corrects an issue with folder security override.



7.1.302

ACM Server

Issue

Corrects an issue with the alias group activate tags option where it had to be disabled then re-enabled to operate properly.



7.1.302

ACM Server

Issue

Imposed a limit on the number of API custom interface item groups to avoid memory saturation.



7.1.302

ACM Server

Issue

Improves the ability to re-connect to the database in the event of a disconnect.



7.1.302

Client Application

Feature

Adds a feature where users may republish a device.



7.1.302

Client Application

Feature

Adds a maximum record count for report viewer.



7.1.302

Client Application

Feature

Adds a user preference for when to activate alias tags on the new dashboard status tab.



7.1.302

Client Application

Feature

Adds Archive Reporting and Management feature.



7.1.302

Client Application

Feature

Adds client DLL information to the 'View Client/Server info' display.



7.1.302

Client Application

Feature

Adds dashboard for Health & Status.



7.1.302

Client Application

Feature

Adds support for multi-select on search results.



7.1.302

Client Application

Feature

Adds support in the Station Wizard for the Daniels Gas Chromatograph.



7.1.302

Client Application

Feature

Adds support to the Station Wizard for creating and linking connections and schedules.



7.1.302

Client Application

Issue

Corrects an issue in the multi-object editor where CategoryName was missing.



7.1.302

Client Application

Issue

Corrects an issue when making a change to database properties and not saving before changing tabs.



7.1.302

Client Application

Issue

Corrects an issue where a value in the record collection dialog was not displayed correctly.



7.1.302

Client Application

Issue

Corrects an issue where changing a property in a time synchronization object changed its icon.



7.1.302

Client Application

Issue

Corrects an issue where folder multi-select followed by single-select behaved oddly.



7.1.302

Client Application

Issue

Corrects an issue where object names could contain trailing spaces.



7.1.302

Client Application

Issue

Corrects an issue where opening a device from a search was not working.



7.1.302

Client Application

Issue

Corrects an issue where ROC History Map user fields were lost upon export/import.



7.1.302

Client Application

Issue

Corrects an issue where the logger did not return to 'Play' after being paused on a scroll event.



7.1.302

Client Application

Issue

Corrects an issue where the logger was able to be paused even when empty.



7.1.302

Client Application

Issue

Corrects an issue where the multi-object editor could error on numeric values.



7.1.302

Client Application

Issue

Corrects an issue where the Multi-object editor was not saving applied filters.



7.1.302

Client Application

Issue

Corrects an issue where the object count was missing when accessed from Category view.



7.1.302

Client Application

Issue

Corrects an issue where the user interface was not correctly saving modified enumerations.



7.1.302

Client Application

Issue

Corrects an issue with the importer where line breaks could cause unexpected results.



7.1.302

Client Application

Issue

Corrects an issue with the importer where linked objects were getting lost.



7.1.302

Client Application

Issue

Corrects an issue with the multi-object editor and Hex Repeater Action Groups.



7.1.302

Client Application

Issue

Improves the multi-object editor to allow for editing of common properties regardless of type.



7.1.302

Client Application

Issue

Improves the performance of the log viewer so it does not lag behind.



7.1.302

Client Application

Issue

Improves the speed with which object tabs are closed.



7.1.302

Client Application

Issue

Updated object icons.



7.1.302

Connections: Base Connection

Feature

Adds logic to prevent task starvation that causes a high volume of high priority tasks to prevent lower priority tasks from running.



7.1.302

Connections: Base Connection

Issue

Corrects an issue where the Queue Viewer can see 'orphaned' polls when switching between primary and secondary connections.



7.1.302

Connections: TCPIP Connection

Feature

Adds new OPC Item 'CurrentHost' to indicate which Host Address is current.



7.1.302

Connections: TCPIP Connection

Issue

Corrects an issue where queue viewer messages were not being removed upon completion when switching between primary and alternate connections.



7.1.302

Connections: TCPIP Connection

Issue

Corrects an issue where the lost connection timeout was not always accurate.



7.1.302

Connections: TCPListen Connection

Issue

Corrects an issue where only some of the devices start to poll when at least 'max sessions' of them are due at once.



7.1.302

Connections: TCPPool Connection

Issue

Corrects an issue where demand stayed on after polling failed due to a lack of response.



7.1.302

Connections: TCPPool Connection

Issue

Corrects an issue where lost connection timeout was not properly reset on valid response.



7.1.302

Connections: TCPPool Connection

Issue

Corrects an issue where modem health was incorrect when the 'Release when done' option was used.



7.1.302

Connections: TCPPool Connection

Issue

Improves TCP Pool so that it can try another modem port within the same poll cycle if the previous modem failed initialization.



7.1.302

Protocols: Base Protocol

Feature

Adds continuous scan.



7.1.302

Protocols: Base Protocol

Feature

Adds the ability to turn on continuous scan for a set number of seconds.



7.1.302

Protocols: Base Protocol

Issue

Removed obsolete property ‘SwitchDelay’. This may cause error messages during startup. These error messages can be safely ignored. These properties can be removed from the database by running the ‘DbCleanup.sql’ script generated during ACM startup. This file can be found in the ACM data directory.



7.1.302

Protocols: BP Wellcontrol Modbus Protocol

Feature

Adds new support for device BP WELLCONTROL.



7.1.302

Protocols: BSAP Protocol

Feature

Adds support for ControlWave devices to use list numbers greater than 255.



7.1.302

Protocols: BSAP Protocol

Issue

Corrects an issue where polling failed to resume after the device was interrupted by another device on the same connection.



7.1.302

Protocols: ControlLogix Protocol

Feature

Adds support for the connection tag modifiers <C1> and <C2>.



7.1.302

Protocols: ControlLogix Protocol

Issue

Corrects an issue where internal tags were causing the connection to attempt connection even when disabled.



7.1.302

Protocols: ControlLogix Protocol

Issue

Corrects an issue where the tag discovery process was receiving an incomplete message and crashing.



7.1.302

Protocols: ControlLogix Protocol

Issue

Corrects an issue with multidimensional writes (tag[0,1]).



7.1.302

Protocols: ControlLogix Protocol

Issue

Corrects an issue with the LEN string write option.



7.1.302

Protocols: ControlLogix Protocol

Issue

Important: The option to enable non-listed tags is now defaulted to ‘enabled’. If you have an existing configuration and use the ‘Enable Non-Listed Tag Validation’ option, OPC items not found in the driver’s saved tag file must now have a data type specifier appended to their names (example: MyBool;C1).



7.1.302

Protocols: ControlLogix Protocol

Issue

Improves CONTROLLOGIX driver to better handle errors from the RegisterSession command using an EIP encapsulated header.



7.1.302

Protocols: DF1 / ABTCP Protocol

Feature

Adds support for the Test Communications feature.



7.1.302

Protocols: DF1 / ABTCP Protocol

Issue

Corrects an issue where gas chromatograph writes were malformed.



7.1.302

Protocols: DF1 / ABTCP Protocol

Issue

Corrects an issue where polling errors were not being logged.



7.1.302

Protocols: DF1 / ABTCP Protocol

Issue

Corrects an issue with PLC5 Serial response.



7.1.302

Protocols: DF1 / ABTCP Protocol

Issue

Corrects invalid values for flowing time and low flow cutoff alarms.



7.1.302

Protocols: DNP3 Protocol

Feature

Adds support for Emerson FBx flow computers using the DNP3 protocol.



7.1.302

Protocols: DNP3 Protocol

Issue

Corrects an issue where message response bytes were logged repeatedly in the logs.



7.1.302

Protocols: DNP3 Protocol

Issue

Improves the handling of large message fragments.



7.1.302

Protocols: Eagle Protocol

Issue

Corrects an issue with Reset Audit Trail feature.



7.1.302

Protocols: Flow Automation Protocol

Issue

Corrects an issue where alarm and event archives were repeating uploads.



7.1.302

Protocols: Flow Automation Protocol

Issue

Corrects an issue where Gas Chromatograph write functions were being requested of a device that does not support such writes.



7.1.302

Protocols: Flow Automation Protocol

Issue

Corrects an issue with function code 34.



7.1.302

Protocols: Hex Repeater Protocol

Issue

Corrects an issue where a demand poll would be repeated without being requested.



7.1.302

Protocols: Hex Repeater Protocol

Issue

Improves time synchronization user interface and logging.



7.1.302

Protocols: Kimray Modbus Protocol

Issue

Improves logging to better inform the user when an archive is misconfigured.



7.1.302

Protocols: Kinder Morgan Modbus Protocol

Issue

Corrects an issue where ACM got out of sync with device history after a device restart.



7.1.302

Protocols: Mercury Protocol

Feature

Adds a new /string modifier to better control data type.



7.1.302

Protocols: Mercury Protocol

Feature

Adds default login information.



7.1.302

Protocols: Mercury Protocol

Feature

Adds Mercury version number to the PGAS publisher.



7.1.302

Protocols: Mercury Protocol

Feature

Adds new option for mapping of EFM volume.



7.1.302

Protocols: Mercury Protocol

Feature

Adds the ability to schedule meter configuration polls.



7.1.302

Protocols: Mercury Protocol

Issue

Corrects an issue where a duplicate history record could stop the poll.



7.1.302

Protocols: Mercury Protocol

Issue

Corrects an issue where OPC item "Status" would display a status of complete when communications are good but the Site id is incorrect.



7.1.302

Protocols: Mercury Protocol

Issue

Corrects an issue where using the RR command for Audit Trail collection could result in error.



7.1.302

Protocols: Mercury Protocol

Issue

Corrects an issue where volume conversion 'publish in MCF' option was using CF.



7.1.302

Protocols: Mercury Protocol

Issue

Corrects an issue where volume data would report incorrectly with option to convert to MCF.



7.1.302

Protocols: Mercury Protocol

Issue

Improves ability to return multiple records within a single response.



7.1.302

Protocols: Mercury Protocol

Issue

Improves the message retry feature to occur if the sign on and wake up failed due to error code.



7.1.302

Protocols: Mercury Protocol

Issue

Improves the validation of EFM records to not include records with dates in the future.



7.1.302

Protocols: Mercury Protocol

Issue

Maximized the performance of polls with multi-record history reads.



7.1.302

Protocols: Modbus Protocol

Feature

Adds MODBUS Broadcast Mode.



7.1.302

Protocols: Modbus Protocol

Feature

Adds support for low priority writes <lpw> and delayed writes <dw>.



7.1.302

Protocols: Modbus Protocol

Issue

Corrects an issue where a "Test Communication" command reported a misleading error message when the device is misconfigured.



7.1.302

Protocols: Modbus Protocol

Issue

Corrects an issue where a checksum error was causing a crash.



7.1.302

Protocols: Modbus Protocol

Issue

Corrects an issue where a time synchronization error was logged when there was no error.



7.1.302

Protocols: Modbus Protocol

Issue

Corrects an issue where auto recovery would attempt to switch communications back to the primary schedule before the current poll is complete.



7.1.302

Protocols: Modbus Protocol

Issue

Corrects an issue where the demand flag is stuck 'on'.



7.1.302

Protocols: Modbus Protocol

Issue

Corrects an issue where the register count and byte count included in Modbus multi-register write messages was not consistent with the number of bytes and registers actually written.



7.1.302

Protocols: Modbus Protocol

Issue

Corrects an issue with the MODBUS bit display modifier (L/0.32).



7.1.302

Protocols: Modbus Protocol

Issue

Important: Devices with an address value of zero are treated as write-only broadcast devices.



7.1.302

Protocols: Modbus Protocol

Issue

Improves efficiency of write requests when data is of disparate types.



7.1.302

Protocols: Modbus Protocol

Issue

Improves MODBUS driver to avoid a crash that could occur upon receipt of invalid data.



7.1.302

Protocols: Modbus Protocol

Issue

Improves the polling process when a CRC error is returned from a device.



7.1.302

Protocols: Omni Modbus Protocol

Issue

Corrects an issue where prove records were not processed correctly if there were multiple prove records on multiple meters.



7.1.302

Protocols: Prosoft Modbus Protocol

Feature

Adds error messaging to alert the user when the configured message size is not sufficient to hold the expected response.



7.1.302

Protocols: Reynolds Protocol

Feature

Adds the ability to map uncorrected volume to PGAS EFM field 'index off'



7.1.302

Protocols: ROC Protocol

Issue

Add Gas Chromatograph fields to the 800L liquid meter configuration map.



7.1.302

Protocols: ROC Protocol

Feature

Adds a button to display the default mapping on the ROC dialog.



7.1.302

Protocols: ROC Protocol

Feature

Adds DS800 OPC tags.



7.1.302

Protocols: ROC Protocol

Feature

Adds support for FB1000/FB2000 series Flow Computers.



7.1.302

Protocols: ROC Protocol

Feature

Adds the ability to collect extended history from a ROC even if it has no standard history configured.



7.1.302

Protocols: ROC Protocol

Issue

Corrects an issue where bad TLPs in OPC (due to data type) caused good tags following them to also be bad.



7.1.302

Protocols: ROC Protocol

Issue

Corrects an issue where Extended history was not polling points 23, 24 and 25.



7.1.302

Protocols: ROC Protocol

Issue

Corrects an issue where OPC tag LastTimeSyncResult was inconsistent.



7.1.302

Protocols: ROC Protocol

Issue

Corrects an issue where the OPC browse section "MISCELLANEOUS" was missing.



7.1.302

Protocols: ROC Protocol

Issue

Improves support for polling of the ROC800 Liquid LiquidCalcs program.



7.1.302

Protocols: ROC Protocol

Issue

Improves the Coriolis Meter Override feature to include override of Calculation Method.



7.1.302

Protocols: SCADAPack Protocol

Feature

Adds advanced meter configuration capability to SCADAPACK.



7.1.302

Protocols: SCADAPack Protocol

Feature

Adds support for the retrieval of liquid history.



7.1.302

Protocols: SCADAPack Protocol

Issue

Corrects an issue where ASI Data Service would crash with SCADAPACK Test Communication command.



7.1.302

Protocols: Totalflow Protocol

Feature

Adds a scheduling interval option for meter configuration read.



7.1.302

Protocols: Totalflow Protocol

Feature

Adds mapping for EFM fields 'OPEN IV' and 'CLOSE IV'.



7.1.302

Protocols: Totalflow Protocol

Feature

Adds new 'Low Bandwidth' feature.



7.1.302

Protocols: Totalflow Protocol

Feature

Adds support for limiting old data for Totalflow trends.



7.1.302

Protocols: Totalflow Protocol

Issue

Adding support for Debounce input reads



7.1.302

Protocols: Totalflow Protocol

Issue

Adding support for processing unsolicited messages.



7.1.302

Protocols: Totalflow Protocol

Issue

Corrects an issue where deleting an internal duplicate EFM configuration field more than once could result in a crash.



7.1.302

Protocols: Totalflow Protocol

Issue

Corrects an issue where EFM field 'CTPL' was not being published correctly.



7.1.302

Protocols: Totalflow Protocol

Issue

Corrects an issue where for some event types, the old and new values would mistakenly be the same.



7.1.302

Protocols: Totalflow Protocol

Issue

Corrects an issue where 'Observed Density' was published incorrectly.



7.1.302

Protocols: Totalflow Protocol

Issue

Corrects an issue where requesting max records for one upload type but not all resulted in error.



7.1.302

Protocols: Totalflow Protocol

Issue

Corrects an issue where scheduling switched from alternate back to primary prematurely.



7.1.302

Protocols: Totalflow Protocol

Issue

Corrects an issue where the archive limits object was not applied properly.



7.1.302

Protocols: Totalflow Protocol

Issue

Corrects an issue where the OPC tag 'DateTime' was not being resolved correctly.



7.1.302

Protocols: Totalflow Protocol

Issue

Important: The default behavior for history retrieval is now to use Low Bandwidth mode when in a communication retry. This can be changed through the device configuration (This note added February 11, 2019).



7.1.302

Protocols: Totalflow Protocol

Issue

Improves error messaging when archive is not configured.



7.1.302

Protocols: Totalflow Protocol

Issue

Improves validation of time synchronization objects to avoid crash.



7.1.302

Publishing

Feature

Adds a new option where users may configure the database publisher to ignore ORACLE constraints



7.1.302

Publishing

Feature

Adds AGA3-2013 and other constants to validation functions for CFX and OLFP.



7.1.302

Publishing

Feature

Adds custom field mapping to the PGAS XML publisher.



7.1.302

Publishing

Feature

Adds handling for RecordStartDate, RecordStartTime, RecordEndDate, & RecordEndTime for protocols with batch records that send those fields in separately.



7.1.302

Publishing

Feature

Adds new PGAS/XML properties.



7.1.302

Publishing

Feature

Adds precision options to the FLOWCAL publishers.



7.1.302

Publishing

Feature

Adds 'sediment and water percent' value to the PGAS XML quality record.



7.1.302

Publishing

Feature

Adds SP_LOW_SPAN and SP_HIGH_SPAN to PGAS XML meter configuration.



7.1.302

Publishing

Feature

Adds support for redundant output to the PGAS XML publisher.



7.1.302

Publishing

Feature

Adds support for the republication of specific devices or meters.



7.1.302

Publishing

Feature

Adds the AGA3-2013 calculation method.



7.1.302

Publishing

Feature

Adds user configurable XML element options to the PGAS XML publisher.



7.1.302

Publishing

Issue

Allow AGA7 as a valid calculation method for Coriolis meters.



7.1.302

Publishing

Issue

Corrects a logging message regarding the number of records processed.



7.1.302

Publishing

Issue

Corrects an issue where empty token values could prefix filenames with '0'.



7.1.302

Publishing

Issue

Corrects an issue where FLOWCAL publishers failed to translate 'Totalizer Digits'.



7.1.302

Publishing

Issue

Corrects an issue where 'Millibar Differential Pressure' was missing from CFX output files.



7.1.302

Publishing

Issue

Corrects an issue where the collection time on a meter configuration record was actually a history collection time.



7.1.302

Publishing

Issue

Corrects an issue where the PGAS XML publisher was using the wrong value for "QTY_CALC_PERIOD".



7.1.302

Publishing

Issue

Corrects an issue where the publisher filter was not appropriately applying to meter only records.



7.1.302

Publishing

Issue

Corrects an issue where the publisher would crash due to the 'Leading Timestamp' option.



7.1.302

Publishing

Issue

Corrects an issue with CorrectedMass not appearing in volume records.



7.1.302

Publishing

Issue

Improve the logic when looking for future dates where the future extends beyond 2038.



7.1.302

Publishing

Issue

Improves PGAS/XML GC output.



7.1.302

Publishing

Issue

Improves the PGAS XML publisher to better handle time changes.



7.1.302

Publishing

Issue

Increased potential length of the custom header string in CSV publisher.



7.1.302

Publishing

Issue

Update PGAS characteristics fields to latest v16 specification.



7.1.302

Publishing

Issue

Updated FLOWCAL publishers to synchronize with the latest updates.



7.1.302

Publishing

Issue

Updated the PGAS XML publisher so that gas analysis data may be processed with the new GQ Periodic node.



7.1.302

Reports

Feature

Adds a report for meters published by publisher filter.



7.1.302

Reports

Feature

Adds a report to show an audit trail of commands sent.



7.1.302

Reports

Feature

Adds scheduled reports.



7.1.302

Reports

Issue

Corrects an issue where the Archive Table Report was omitting records if a meter was specified.



7.1.302

Protocols: Omni Protocol

Feature

Adds positive displacement meter type for Omni firmware 22 and 26.



7.1.302

Reports

Issue

Corrects an issue where a report's timestamp could be incorrect if the report was collected by command.



7.1.302

Protocols: Base Protocol

Issue

Corrects an issue where history collection is impacted when the GC archive has a different buffer size than periodic archive.



7.1.302

Publishing

Issue

Corrects an issue where liquid product alpha unit and EQ vapor pressure unit were being reported when the liquid table did not require it to be included.