Commands

CommandDescriptionParameters

Test Communication

When executed, ACM will poll a known OPC item from the device and wait for the response to see if the communication is good.None
Retrieve HistoryRequests the retrieval of all enabled archive record types.None
Retrieve Meter Config during next history pollRetrieves meter configuration data for all meters during the next history retrieval.None
Retrieve audit log config during next history pollRetrieves the information the driver uses to identify the data that is in the audit log records during the next history retrieval.None
Retrieve device config during next history pollRetrieves the device configuration during the next history retrieval (firmware version, etc).None
Reset Audit PointerClears the audit retrieval position so retrieval starts at the oldest record.None
Reset Event PointerClears the event retrieval position so retrieval starts at the oldest record.None
Reset Alarm PointerClears the alarm retrieval position so retrieval starts at the oldest record.None
Move Audit Pointer BackMoves the saved audit retrieval position to an older record. Enter the Timestamp to move back.Timestamp
Skip AuditMoves the saved hourly retrieval position forward. Enter the number of records to skip.Record Count
Time SyncCauses a comparison of the date and time in the device to the host date and time. Once compared, the configured rules of the selected time sync object will be applied - including time zone and daylight saving options.None

For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.