BSAP Commands
BSAP Commands
Common Commands
See Device Object Common Commands for commands that are common to all device types.
Commands
Command | Description | Parameters |
---|---|---|
Test Communication | When executed, ACM will poll a known OPC item from the device and wait for the response to see if the communication is good. | None |
Time Sync | Causes a comparison of the date and time in the device to the host date and time. Once compared, the configured rules of the selected time sync object will be applied - including time zone and daylight saving options. | None |
Retrieve meter config during next history poll | Retrieves meter configuration data for all meters during the next history retrieval. | None |
Retrieve History | Requests the retrieval of all enabled archive record types (for all enabled meters) | None |
Reset Audit Pointer | Clears the audit retrieval position so retrieval starts at the oldest record. | None |
Reset Hourly Pointer | Clears the hourly retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Meter Number |
Reset Daily Pointer | Clears the daily retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Meter Number |
Reset Minute Pointer | Clears the minute retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Meter Number |
Move Audit Pointer | Moves the saved audit retrieval position. Enter the number of records: positive to move backward, negative to move forward. Meter Number not used for audit uploads | Meter Number Record Count |
Move Hourly Pointer | Moves the saved hourly retrieval position. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of records: positive to move backward, negative to move forward. | Meter Number Record Count |
Move Daily Pointer | Moves the saved daily retrieval position. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of records: positive to move backward, negative to move forward. | Meter Number Record Count |
Move Minute Pointer | Moves the saved daily retrieval position. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of records: positive to move backward, negative to move forward. | Meter Number Record Count |
Reset User Archive 1-16 Pointer | Clears the archive retrieval position so retrieval starts at the oldest record. Provide the meter number in parameter one, or leave blank for all meters. | Meter Number |
Move User Archive 1-16 Pointer | Moves the saved archive 1-16 retrieval position. Provide the meter number in parameter one, or leave blank for all meters. Enter the number of records: positive to move backward, negative to move forward. | Meter Number Record Count |
, multiple selections available,
Related content
BSAP OPC Items
BSAP OPC Items
Read with this
BenchMark Commands
BenchMark Commands
More like this
Romet Commands
Romet Commands
More like this
Eagle Commands
Eagle Commands
More like this
ROC Commands
ROC Commands
More like this
SCANCOM Commands
SCANCOM Commands
More like this
For assistance, please submit a ticket via our Support Portal, email autosol.support@autosoln.com or call 281.286.6017 to speak to a support team member.