Beginning July 2020, ACM will only support Microsoft operating systems and servers that are also still supported by Microsoft.
If you have a support agreement, the new ACM version can be downloaded by using the monthly login credentials received from your sales representative. For more details, please contact us today.
Components from ACM 8 cannot be combined with components from ACM 7.
ACM 8.1 includes a Beta release of the OMNI 7000 driver. This driver:
The Totalflow driver in ACM 8.1 has been updated to use the latest functionality available in the 3.12 version of the ABB toolkit. The driver can now be used with RMC models that support many more meters than previous models. New functionality includes:
Added support for Coriolis and Ultrasonic meter types.
|
Gas Analysis data can be retrieved from periodic records in enhanced meters.
Gas analysis values can be published from the “extra data” associated with each log period or daily record in enhanced meters. |
Standardized the gas analysis location and format.
The history record output format has changed to standardize the location, order and content of the gas analysis fields. When configured to be included in the output, all gas analysis fields will be published. Fields without data will have an empty or 'null' value in the output record. |
Beginning June 2021, ACM 7.1 Build 306 and earlier will no longer receive new updates. Please contact support to assist you in upgrading to ACM 8 to make sure you have access to the latest features!
Added mapping for SP Transducer Range High to SP_HIGH_RANGE in the PGASXML publisher.
When an EFM record contains SP Transducer Range High, SP_HIGH_RANGE is assigned and present in the output file. |
Modified the PGASXML history type to convert values that are in an energy unit other than MMBTU, DTH or GJ to DTH.
When an unsupported energy unit is submitted with a PGAS record, the value and unit will be converted to DTH. |
Implemented support for the Pulse Accumulator Meter Run 2.
Published data may contain EFM records for Meter Run 2 for a Pulse Accumulator. |
Added an option to publish the K-Factor units in “Pulses per Cubic Meter” instead of “Pulses per Cubic Foot” when the device is using cubic meters.
If this option is selected, K-Factor units will not be converted to pulses per cubic feet when the device is using cubic meters. |
Added variables Octane, Nonane and Decane to the ROC800L Internal Map.
Octane, Nonane and Decane fields will be published for ROC devices. |
Corrected an issue with bit offsets causing a 1 to be returned instead of VARIANT_TRUE (-1).
May affect published output if the previous output expected "1" or had a conversion in place to change to -1. |
Corrected an issue that caused non-configured station meter data to be published.
Non-configured station meter data will no longer be published. |
Corrected an issue that caused incorrect values to be published for Audit Trail volume units for non-350 series devices.
Audit record volume units for non-350 series Mercury devices will now have correct values. |
Corrected an issue that caused EFM history records to always be published with a value of 60 for the $$Record.Period$$ field.
EFM history records are now published with the correct value in the $$Record.Period$$ field. |
Corrected an issue that caused the LogTrigger column to be missing from a CSV Audit Report.
The CSV audit report will contain the LogTrigger column by default. This may add an additional column to the CSV report. |
Modified the contents of the LogTrigger column in a CSV Audit Report to contain the entire T&A value.
The LogTrigger column in the CSV audit report will now contain the entire T&A field value. |
Corrected an issue that could cause non-time triggered audit records to be published even when the ACM device object was not configured to do so.
Non time-triggered audit records will only be published if the ACM device object is configured to do so. |
Corrected an issue that prevented an item's unit value from being published in the audit record if the item's units could not be resolved.
Item unit values are now published for all items in the audit record, including the items that do not have an associated unit. This may add additional columns to a CSV report. |
Corrected an issue that caused audit records with invalid timestamps to be published. Instead an error message will be logged.
Audit records with invalid timestamps will no longer be published. |
Corrected an issue returning a "***Requested too many events***" message when the event or alarm archive wraps around to the top.
Events and alarms that were not being published due to this issue will now be published. |
Corrected batch record processing to map the batch record to the correct meter configured in the external map when the external map is applied.
The record will be output as the correct meter. |
Corrected an issue that caused EFM history records to always be published with a value of 60 for the $$Record.Period$$ field.
EFM history records are now published with the correct value in the $$Record.Period$$ field. |
Corrected an issue that prevented the LogTrigger column from appearing on a CSV Audit Report.
The CSV audit report will contain the LogTrigger column by default. This may add an additional column to the CSV report. |
Modified the contents of the LogTrigger column in a CSV Audit Report to contain the entire T&A value.
The LogTrigger column in the CSV audit report will now contain the entire T&A field value. |
Corrected an issue that could cause non-time triggered audit records to be published even when the ACM device object was not configured to do so.
Non time-triggered audit records will only be published if the ACM device object is configured to do so. |
Corrected an issue that prevented the K-Factor value from being published.
Non time-triggered audit records will only be published if the ACM device object is configured to do so. |