Major Version Change

Components from ACM 9 cannot be combined with components from ACM 7 nor ACM 8.

Database Version

Components from ACM 7 and ACM 8 cannot be combined with Version 40 of the ACM Configuration Database.

ACM 9.0 Installation Notes

If you have a support agreement, the new ACM version can be downloaded by using the monthly login credentials received from your sales representative.  For more details, please contact us today.

Important reminders

Mercury devices already configured in ACM will continue to work using the legacy protocol driver, but updates are no longer available.

As of June 2021, ACM 7.1 Build 306 and earlier no longer receive new updates. Please contact support to assist you in upgrading to ACM 9 to make sure you have access to the latest features!

ACM OPC UA

OPC UA is an open, reliable interface used to transfer information between servers and clients.

Additional Features:

View the OPC UA Server for ACM user guide for more information.

AUTOSOL Bridge

ACM can now subscribe to a broker publishing MQTT in SparkplugB format using the AUTOSOL Bridge service. AUTOSOL Bridge can be configured, started and stopped from within the Server Monitor. Note: at least one broker must be configured to start asiBridge. View AUTOSOL Bridge Configuration for more information.

A separate license is required for AUTOSOL Bridge. Contact your AUTOSOL Sales Representative or AUTOSOL Customer Support for more information.

Weatherford 8500

ACM now supports the Weatherford 8500 Protocol

Features Added

Client Application

Configuration Database

Protocols

BSAP Protocol

DNP3 Protocol

Effect on Published Output

When the "Use history points from device" option is selected, the FBx history header will be used to publish history records.

Effect on Published Output

When the "Use meter config from device" option is checked, published event, alarm and meter configuration records will be determined by the FBx meter config file.

Honeywell - Mercury Protocol

Micro MP3 Protocol

Effect on Published Output

Alternative (non-truck-loading) batch records can now be published.

ROC Protocol

Effect on Published Output

The compressibility fields (Zs and Zb) of the meter configuration record will now be published.

Effect on Published Output

If the new option is used, volume will be published to INDEX_OFF and INDEX_ON will be set to zero in the PGAS output.

Effect on Published Output

Publisher outputs will now include 'Tap Type' in the meter configuration.

Effect on Published Output

Ultrasonic Data can now be published to the FLOWCAL Transaction Queue

Effect on Published Output

If configured in the device, HART tags will be used for Process Limits when publishing meter configuration records for ROC 800 gas and liquid devices..

Effect on Published Output

When the new option "Use indicated volume for mass in mass meters." is selected, indicated volume will be published as mass for liquid mass meters. If not selected, mass will be published.

Effect on Published Output

V-Cone meter data can now be published.

SCADAPack Protocol

Weatherford Protocol

Publishing

Effect on Published Output

If the new PGAS XML option "Create files per record type" is selected, meter characteristic records will be stored separately from other record types in PGAS XML published outputs.

Effect on Published Output

Protocols that use a configurable archive object can now be configured to skip specific EFM record fields when publishing.

Issues Addressed

ACM Server

API

Client Application

Configuration Database

Logging

OPC Items

Protocols

All Protocols

Benchmark Protocol

BSAP Protocol

ControlLogix Protocol

DNP3 Protocol

Flow Automation Protocol

Honeywell - Mercury Protocol

NGCTT Protocol

ROC Protocol

Effect on Published Output

ROC800 events for history segment changes are output correctly via CFX and Transaction Queue publishers.

Effect on Published Output

Complete records will be published when mapping and combining points from different segments, even when the segment pointers are misaligned.

Romet-Adem Protocol

SCADAPack Protocol

Effect on Published Output

The correct value for Pipe Material will be published.

Scancom Protocol

Teledyne CA Protocol

Totalflow Protocol

Effect on Published Output

The "Use FT" AND "Use FB" event values will be correctly formatted when publishing to CFX or Transaction Queue.

Publishing

Effect on Published Output

The correct values for SP and DP calibration will now be output in the PGAS XML publisher.

Effect on Published Output

The Contract Hour and Contract Day will be output to FLOWCAL Transaction Queue.

Effect on Published Output

The sort order of CFX output when publishing "Meters Only" will always be by "RecordTS".

Reports

Server Monitor