titleSaving Record Collection Changes

When record editing is complete, Click Close to return to the owning object type. Click the Save button  to save any changes made to the record collection.


New Record Configuration

Field Identifier

Default = Unknown. Select the identifier from the Selection form.

Flags or Scale

Default = None. Used for scaling with known factors. Select from the drop-down listing. This option can also be used to convert numeric values into date and time values which may be necessary when using archive fields at time stamps.

Meter Run

Default = Run 1. 

Period

Default = Hourly.

RecordId

Name of record in collection.

...

For customized scaling. If using customized scaling, Flags or Scale option can be set to “None.” This scale string can further scale the value as desired (ex: gain and offset). This option can also convert numeric values into date and time values which may be necessary when using archive fields at time stamps.

Info
titleNote

If both Flags or Scale and Scale String are used, then the Flags or Scale selected option will be scaled first and then the Scale String entry will be scaled second.

Unit Identifier

Default = Unitless. Select the unit from the unit Custom Unit selection form.

Map Example

For Omni, values are scaled using the following formula: Register 1 value after scale = Register 1 value before scale / scale factor.

...