This item is used by the End Device item. It defines the connection the Edge Device will use to connect to the End Device

Every End Device requires a Connection Settings object, so it is suggested you create this before creating the End Device object.

Property

Description

Name

The name of this item

Host IP

The number of times a poll message will be tried before a reconnect is attempted

Host Port

The port of the End Device you will connect to

Connection Timeout (ms)

The time, in milliseconds, Edge ACM will wait for a response from the End Device after trying to connect

Connection Interval (ms)

The time, in milliseconds, Edge ACM will wait before attempting to reconnect to the end device after a disconnect

Poll Interval (ms)

The time, in milliseconds, between polls

Response Timeout (ms)

The time, in milliseconds, Edge ACM will wait for a response from the End Device before retying the message

Timer Tick (ms)

The time, in milliseconds, Edge ACM will wait for a response from the End Device before retying the message

Poll retries

The number of times a poll message will be tried before a reconnect is attempted

Folder

The parent folder for this item