Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

*Use the "shift" key to sort by multiple columns.

ReleaseTypeCategoryDescriptionAffects Published OutputAddresses Security Vulnerability
9.1.2IssueAlias Groups/ItemsCorrects an issue that caused items within an alias group to be internally advised and ready for MQTT publishing by a copied device object, even when the alias group did not have MQTT publishing enabled.

9.1.2IssueAPICorrects an issue that prevents a solution utilizing the API in an ASP.NET environment from finding the AutoSol.ACM.Config.Client file.

9.1.2IssueClient ApplicationRestores the User Preference Activate Alias Tags on Status Tab "Only when Alias Group tags are active" option.

9.1.2IssueClient ApplicationRemoves the unused 'Alarm Service' fields from the ACM Connect to Server Options.

9.1.2IssueClient ApplicationPrevents spaces from being saved at the beginning or end of the Connect String field.

9.1.2IssueClient ApplicationIncreases the character limit of the "Provider String" field to 512 characters for the EFMDB and DB output types.

9.1.2IssueClient ApplicationChanges the default button on the "Delete Objects" dialog to "Cancel".

9.1.2IssueClient ApplicationPrevents the Config Client from disconnecting from the server when using special characters in the search tool.

9.1.2IssueClient ApplicationCorrects sorting for datetime columns in the Dashboard.

9.1.2IssueClient ApplicationCorrects an issue that caused the search functionality to only find matching objects if those objects with descriptions.

9.1.2IssueClient ApplicationCorrects an issue that caused the search functionality to fail to find matches when there was a leading or trailing space in the search criteria.

9.1.2IssueClient ApplicationCorrects an issue that could leave items advised and polling when switching between different alias groups on the Status tab of a device configuration form.

9.1.2IssueClient ApplicationChanges the labels in the Publisher CSV from "Publish Report Records" to "Publish All Report Records" and "Publish Prove Report Records" to "Publish Prove Records".

9.1.2IssueConfiguration DatabaseUpdates variables in two stored procedures, asi_spResetPublisherPosition_Filter and asi_spResetPublisherPosition, from INT to BIGINT to allow for large archive sequence IDs.

9.1.2IssueConfiguration DatabaseUpdates the asi_spFrequentalarmandEventReport stored procedure to use the alarmLimitEvent parameter.

9.1.2IssueConfiguration DatabaseAdds the table 'EdgeEFMConfigurationErrors' to the ACM database to record errors that may occur when publishing EFM data from the Edge.  These errors will be visible in the 'Error Log Report Last X Days' report.

9.1.2IssueConfiguration DatabaseModifies the "Publish a Device" command on the Publisher Command tab to publish all records, regardless of filter settings.  Previously if the filter was for meters only, it would log "No records published for ObjectId = ### as it is not contained in the filter". This is a database update to the asi_spInsertPublishObjects4 stored procedure. *Effect On Published Output: When using the "Publish a Device" command from a publisher, all records will be published for that device regardless of filter settings.X
9.1.2IssueConnections: Base ConnectionCorrects the failure retry count of polls that occur after a priority interruption.

9.1.2IssueExportMDBPrevents ACM from replacing an existing Access database backup file with an empty one if asiData cannot connect to SQL Server.

9.1.2IssueGeneralCorrects an error that could occur while saving objects if asiData was disconnected from the SQL Server when using the SQL Driver MSOLEDBSQL version 18.6 or later.  The error messages in ACM addressed by this fix include: "Could not find prepared statement with handle #" and "Procedure {procedurename} has too many arguments specified".

9.1.2IssueGeneralCorrects an issue that caused an invalid timestamp to occur on Leap Day.

9.1.2IssueImporter/ExporterPrevents an error from occurring when importing a "Connect String" with a trailing space.

9.1.2IssueImporter/ExporterPrevents ACM from updating references when the "Cancel" button is clicked from the Import form.

9.1.2IssueImporter/ExporterCorrects an issue encountered while importing Alias Groups with empty record values which prevented the entire Alias Group from getting imported.

9.1.2IssueItem ServerCorrects an issue that caused MinutesSinceComplete to be incorrectly calculated immediately after DST.

9.1.2IssueItem ServerReduces nuisance log messages that appeared while the ItemServer waited for asiDATA to start.  Now the service will wait until asiDATA is running before attempting the IPC connection.

9.1.2IssueKinder Morgan ModbusImproves the handling of unexpected sequence number and archive reset conditions.

9.1.2IssueLoggingAdds additional information to the logger if asiLogger is unable to retrieve the local time and fails to generate a new file at midnight.

9.1.2IssueMQTTCorrects an issue that sent erroneous DDEATH messages to the MQTT broker when the interval on an alias group changed.

9.1.2IssueMQTTCorrects an issue that caused a partially configured broker to require an ItemServer restart before being able to complete the configuration.

9.1.2IssueOPC UACorrects the data type of the initial value update for archive 'Move' and 'Reset' items.

9.1.2IssueOPC UAPrevents inactive OPC UA items from internal updates.

9.1.2IssueOPC UACorrects an issue that caused the 'Restart OPC UA Service' message to be shown when only log flags were changed on the OPC UA configuration dialog.

9.1.2IssueOPC UACorrects an issue that prevented a monitored item from being created on an address space node that has a bad status.

9.1.2IssueOPC UACorrects an issue where the status of a new monitored item would be set to Good when the associated node had a bad status.

9.1.2IssueProsoft ModbusModifies the driver to evaluate the contract hour unit and convert the value accordingly. *Effect On Published Output: The contract hour will be converted using the correct contract hour unit.X
9.1.2IssueProtocols: BSAP ProtocolCorrects an issue that caused BSAP Devices to fail to retrieve history over ethernet connections.

9.1.2IssueProtocols: ControlLogix ProtocolCorrects an issue that prevented the LastPollSuccessTime from updating correctly due to CIP Forward Open errors.

9.1.2IssueProtocols: DNP3 ProtocolCorrects the DNP3 meter type and calculation method mapping.  Previously 'AGA3-2013' was published as 'AGA3-1992' and 'API 12.2 Volumetric' was published as 'Linear Mass'.  Meter Types 'Ultrasonic' and 'Positive Displacement' were previously empty in published output. *Effect On Published Output: The correct calculation method and meter type will now be published.X
9.1.2IssueProtocols: DNP3 ProtocolModifies the Move and Reset commands for alarm and event pointers so that they will execute as long as any meter is assigned.

9.1.2IssueProtocols: DNP3 ProtocolPrevents an OPC Client from activating DNP3 internal items.

9.1.2IssueProtocols: DNP3 ProtocolCorrects the Gain/Offset scaling in the DNP3 FBx protocol. *Effect On Published Output: When set in the Archive Field Configuration, the published raw values will be scaled according to the Gain/Offset Scaling formula ItemName{SG:Gain:Offset}.X
9.1.2IssueProtocols: GE SRTP ProtocolExtends the write message to include more than one item write in the same protocol message.

9.1.2IssueProtocols: Honeywell - Mercury ProtocolModifies the protocol to perform a primary path test before switching from the secondary connection to the primary connection.

9.1.2IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that prevented the Mercury Call-in Schedule from saving the Start, Length, and Interval values.

9.1.2IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that caused an incorrect leading/trailing timestamp indicator to be published for Mini-AT, Mini-Max, AccuTest and TurboCorrector devices. *Effect On Published Output: The correct leading/trailing timestamp indicator will be published.X
9.1.2IssueProtocols: Honeywell - Mercury ProtocolDecodes G items (1600-1699) for the Mercury EC350 series. *Effect On Published Output: The correct value for G items will be published.X
9.1.2IssueProtocols: Honeywell - Mercury ProtocolModifies the 'First Collection Limit' so that the most recent alarm and event Archive records are published instead of the oldest.

9.1.2IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that caused all alarms in the alarm buffer of a Mini-AT to be published on every history upload. *Effect On Published Output: Only the expected alarms will be published when using the RL command to upload alarms.X
9.1.2IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that could cause multiple items to be associated with an RD message when the server was starting.

9.1.2IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that caused a Call-in message to be ignored if a low priority write was currently queued.

9.1.2IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that caused items that were reported as invalid by the RTU to be added back to poll messages.

9.1.2IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that prevented an item write from being sent to device if the write happened during an active poll session.

9.1.2IssueProtocols: Honeywell - Mercury ProtocolPrevents the driver from collecting records that are out of the request range.

9.1.2IssueProtocols: Modbus ProtocolAdds missing Modbus Protocol token values for meter configuration records. *Effect On Published Output: The published output will no longer be missing token values.X
9.1.2IssueProtocols: ROC ProtocolRemoves the "Combine data from all segments into the same archive record" option from non-800 RTUs as it is not applicable. Previously, if used erroneously, it could result in a crash.

9.1.2IssueProtocols: ROC ProtocolCorrects an issue that caused the driver to retrieve all batch records instead of the Batch Archive Limit value.

9.1.2IssueProtocols: ROC ProtocolCorrects an issue where the tag modifier <TJULIAN> was not functional for 4 byte Julian dates.

9.1.2IssueProtocols: Totalflow ProtocolCorrects an issue that prevented Totalflow extended items such as Move Daily and Move event from reverting back to their default value in UA Clients.

9.1.2IssueProtocols: Totalflow ProtocolIncludes the orifice plate reference temperature value in the meter configuration records for orifice meters using the AGA3-2013 calculation method.  Previously it output 'empty/null'. *Effect On Published Output: The orifice plate reference temperature will be published for orifice meters using the AGA3-2013 calculation method.X
9.1.2IssueProtocols: Totalflow ProtocolIncludes additional diagnostic logging when the "Enable message tracing for more logging information" option is selected.

9.1.2IssueProtocols: Totalflow ProtocolCorrects an error that could use the wrong 'remote meter index' when sending GC data to device.

9.1.2IssuePublishingIn the CFX publishers, if the meter contents change from liquid to gas or vice versa, the CFX file will be renamed to include the current timestamp and a new file will be generated.  Previously the publisher would fail. *Effect On Published Output: While the data within the CFX file will not change, the file name may change if a meter's content changes from Liquid to Gas or vice versa.X
9.1.2IssuePublishingCorrects an issue that allowed duplicate periodic records to be published to CFX7 and CFX8 files. *Effect On Published Output: Duplicate periodic records will no longer be published to CFX.X
9.1.2IssueServer MonitorModifies the database form in ACM Monitor so that the "Create/Update Database" button cannot be clicked until a provider is selected.

9.1.2IssueServer MonitorCorrects an issue that caused the wrong "History Deletion Frequency" option to be displayed during create/update database operations via ACM Monitor.

9.1.2IssueServer MonitorUpdates the support package creator to provide more information regarding what can be included and provide more options to configure the contents.

9.1.2IssueServer MonitorCorrects an issue that caused the Database Statistics form to return the error message: "Keyword not supported: 'provider' not allowed.".

9.1.2IssueBulk ManagerChanges the Bulk Manager so that a file that failed to import due to the process being selected as the "DEADLOCK victim" will stay in the import folder.

9.1.2IssueBulk ManagerImproves the log messages to contain more details if a SQL failure occurs.

9.1.2IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that could prevent the driver from sending the log on sequence to the RTU if the last poll cycle ended in comm failure.

9.1.2IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that could cause a received status packet to be ignored if other protocol packets preceded it in the comm buffer, resulting in timeouts.

9.1.2IssueOPC UACorrects an issue that could prevent items in a new Alias Group from being updated if that contained invalid item names.

9.1.2IssueOPC UASets the status of a node that represents an ACM item to 'UncertainLastUsableValue' when all monitored items are removed from the node.

9.1.1IssueBulk ManagerCorrects an issue after upgrading to 9.1.0 that prevented asiBulkMgr from starting until the database connection had been modified in ACM Monitor.

9.1.1IssueClient ApplicationPrevents ACM Configuration from freezing when loading all properties for DNP3 FBx and BSAP devices.  This could occur when selecting the "View All Properties" menu option in the "Type View" of the navigation tree.

9.1.1IssueClient ApplicationPrevents the Dashboard grid from flickering when sorting a large number of records.

9.1.1IssueClient ApplicationRemoves the option to select an alias group object in the "Status" panel of port objects.

9.1.1IssueClient ApplicationMasks the password in the "Provider String" fields on the Database and AUTOSOL EFM Database objects "Database" tabs.

9.1.1IssueClient ApplicationMasks the "Password" field in the "Security" section of the Totalflow "Device" tab.

9.1.1IssueClient ApplicationImproves the loading performance of the Dashboard.

9.1.1IssueClient ApplicationCorrects the multi-line copy and paste capability for the "Comments" column when using multi-object edit tool.  Now text with hard returns will be pasted into a single cell, and the entire cell contents, even if they include a hard return, will be copied.

9.1.1IssueConfiguration DatabaseDeprecated Alias Group properties will be added to the database cleanup script.

9.1.1IssueConnections: TCPIP ConnectionDuring a primary path test, ACM will no longer attempt to connect to the primary port if it was closed with a 'Close Port' command.

9.1.1IssueGC Write ServiceAdds more details for file parsing errors to aid in troubleshooting processing issues.

9.1.1IssueGeneralPrevents loss of data when ACM cannot read the configuration from the database during startup.

9.1.1IssueGeneralCorrects the missing log messages for 'Data sent to client' when the client is an OPC UA client.

9.1.1IssueInstallerCorrects an issue that caused the 64-bit version of ACM to be installed in C:\Program Files(x86) instead of C:\Program Files.

9.1.1IssueInstallerCorrects an issue that may cause the ACM installer to erroneously report that a previous version of ACM is already installed.

9.1.1IssueKinder Morgan ModbusCorrects an issue related to archive sequence number resets.

9.1.1IssueMQTTCorrects an issue that caused asiData to crash when restarting asiItemServer.

9.1.1IssueMQTTAdds configurable logging detail modes for connections, device and item activity between ACM and MQTT broker publishing to aid in troubleshooting.

9.1.1IssueOPC UACorrects the data type of the initial value update for archive 'Move' and 'Reset' items in the Totalflow protocol.

9.1.1IssueOPC UAIncorporates OPC Foundation stack version 1.4.371.96 which includes resolutions for security issues CVE-2023-27321 and CVE-2023-31048.X
9.1.1IssueProtocols: Base ProtocolPrevents a possible memory leak that could occur while processing history records.  This leak only occurred when using a configurable archive object with fields of 'string' data types marked as 'Not Used' for their attribute value with the following protocols: Enron Modbus, Kinder Morgan Modbus, ETNG Modbus, Prosoft Modbus, Benchmark, and BSAP.

9.1.1IssueProtocols: BSAP ProtocolPrevents a memory leak that may occur when using Accol or Signal files for item names.

9.1.1IssueProtocols: BSAP ProtocolCorrects an issue that caused the protocol to retrieve all history each time the "Retrieve History" command was executed. *Effect On Published Output: ACM will no longer republish all history records each time history is retrieved.X
9.1.1IssueProtocols: FlowX ProtocolPrevents repeat error log messages for duplicate tag names when configuring a FlowX History Map object.

9.1.1IssueProtocols: GE SRTP ProtocolPrevents a memory leak that occurs when the GESRTP Protocol validates received responses.

9.1.1IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that created duplicate EFM meter configuration fields. *Effect On Published Output: ACM will no longer publish duplicate EFM meter configuration fields.X
9.1.1IssueProtocols: Honeywell - Mercury ProtocolCorrects the temperature and pressure high/low alarm setpoint values published to the meter configuration record. *Effect On Published Output: ACM will publish the correct temperature and pressure high/low alarm setpoint values.X
9.1.1IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that prevented the driver from converting values correctly when the "Publish volume and related items data and units in MCF" checkbox is checked.

9.1.1IssueProtocols: Modbus ProtocolPrevents a memory leak that could occur when retrieving history in the Modbus Enron and Modbus SCADAPack protocols.

9.1.1IssueProtocols: Omni Modbus ProtocolCorrects a polling error that occurred when using the "Modicon Compatible" option on the Modbus OMNI 7000 "OMNI" tab.

9.1.1IssueProtocols: ROC ProtocolCorrects an issue where the K-Factor override to use Point Type 7 did not function with the new Firmware 2.0+. *Effect On Published Output: ACM will publish the correct K-Factor for devices with the new Firmware 2.0+.X
9.1.1IssueProtocols: SCADAPack ProtocolCorrects the Data Resolution value published to CFX files. *Effect On Published Output: The correct Data Resolution value will be published to CFX files.X
9.1.1IssueProtocols: SCADAPack ProtocolCorrects gas Relative Density and liquid Density output values in history records. *Effect On Published Output: Publishes Relative Density for gas and Density for liquid output in history records.X
9.1.1IssueProtocols: SCADAPack ProtocolPrevents ACM from publishing a partial meter configuration record if the meter configuration data cannot be fully retrieved from the device. *Effect On Published Output: ACM will not publish a partial meter configuration record if that meter configuration data cannot be fully retrieved from the device.X
9.1.1IssueProtocols: SCADAPack ProtocolAdds initial support for new Scadapack 470i and 474i controllers.

9.1.1IssueProtocols: Totalflow ProtocolUses the correct value for the meter serial number when the Archive Collection tab is configured to use the "ACM meter description" as the source for the meter serial number *Effect On Published Output: ACM will publish the correct value for Meter Serial number when using the "ACM Meter Description" as the source.X
9.1.1IssueProtocols: Totalflow ProtocolTurbine meters will now have empty/blank values in the meter configuration record for Pipe Material, Tap Type, and Tap Location. *Effect On Published Output: The output for Turbine meters will now have empty/blank values in the meter configuration record for Pipe Material, Tap Type, and Tap Location.X
9.1.1IssueProtocols: Totalflow ProtocolCorrects the AGA calculation method reported for gas coriolis Totalflow meters. *Effect On Published Output: The correct AGA calculation method will be published for gas coriolis Totalflow meters.X
9.1.1IssueProtocols: Totalflow ProtocolCorrects a memory leak that occurs during history collection if at least one debounce meter and input is assigned.

9.1.1IssuePublishingPrevents a memory leak in the publisher process if a referenced token string cannot be identified.

9.1.1IssuePublishingCorrects a memory leak when using the right-click configuration tree menu option to re-publish history for a device.

9.1.1IssueServer MonitorAdds a new "About" tab to the Server Monitor to simplify reporting information to AUTOSOL Customer support.  The "About" tab displays the Server Version, Server Start Time, Windows Version and License Information.  It also has buttons to open the Log File directory, the Dump File directory and the event Viewer filtered to ACM events.  A fourth button creates a "Support Package" zip file that can be attached to a support ticket. The zip file contents include log files, dump files, events, a few reports and server information.

9.1.1IssueServer MonitorProvides the ability to use an unsecure connection when testing the MQTT and Bridge Broker Connections.  Note: This setting is not suggested for use in a production environment.

9.1.1IssueGeneralPrevents a memory leak that could occur when the asiData service is stopped.

9.1.1IssueGeneralPrevents a memory leak that could occur when configuring View objects.

9.1.1IssueServer MonitorUpdates the "View Client/Server Info" form in ACM Configuration and the "Server information" form in ACM Monitor to include the third digit in the version. This represents the maintenance release number of the ACM server, e.g. 9.1.1.

9.1.1IssueServer MonitorAdds the license information to the "View Client/Server Info" form in ACM Configuration.

9.1.1IssueSiemens S7 ProtocolCorrects an issue with non bit offset writes that was causing the device to return an error.

9.1.1IssueSiemens S7 ProtocolCorrects an issue that prevented some error messages from being logged when the Enhanced logging option was not selected.

9.1.0IssueAlias Groups/ItemsCorrects ACM to use only the $Server alias group if one is assigned.  If an alias group is not assigned to the $Server object, ACM will use the device specific alias groups.

9.1.0IssueAPIModifies the API to enforce validation of maximum/minimum values.

9.1.0IssueAPICorrects an issue connecting to ACM when the API is loaded by an unmanaged process.

9.1.0IssueArchive ManagementCorrects an issue that could cause the Archive Management grid to display an incorrect Contract Hour for various protocols.

9.1.0IssueBridgeCorrects the "Quality of Service" used by asiBRIDGE when it publishes MQTT messages.

9.1.0IssueClient ApplicationModifies the "Copy" functionality so that when copying a device, the meter references will not be copied. This prevents multiple devices polling data for the same meters.

9.1.0IssueClient ApplicationCorrects the tool tip message for the Details tab User01 property.

9.1.0IssueClient ApplicationCorrects an issue that caused the Configuration Manager to disconnect from asiData when searching for certain special characters (e.g parantheses).

9.1.0IssueClient ApplicationCorrects an issue in the Scheduled Report form that caused fields using tokens to be reset.

9.1.0IssueClient ApplicationCorrects an issue that prevented  the object tree from reloading when selecting multiple objects via the search tool.

9.1.0IssueClient ApplicationAdds the $Server and $Perf objects to the object tree in "Type View" and "Category View".

9.1.0IssueClient ApplicationAdds more descriptive error messaging to the object name field.

9.1.0IssueConfiguration DatabaseCorrects casing in sp_InvokeArchiveSnapshot and sp_GetPublisherFilterObjects to prevent errors on SQL Servers with extremely strict case defaults.

9.1.0IssueGC Write ServiceCorrects the use of the tab delimiter and adds validation for delimiters in the GC Write File Service.

9.1.0IssueGeneralCorrects an issue that caused ACM to wait for an OPC Sync Read request to complete when the target device object had been disabled.

9.1.0IssueGeneralChanges the default DCOM authentication level from 'Connect' to 'Packet Integrity'. An override is available and instructions are found here: https://autosoln.atlassian.net/wiki/spaces/ACMDOCS/pages/2516287489/ACM+and+Windows+DCOM+Hardening.X
9.1.0IssueGeneralCorrects an issue that could cause an invalid timestamp in an OPC data change update.

9.1.0IssueImporter/ExporterExcludes missing Alias Group references from exported configuration data and ignores missing Alias Group references during configuration import.

9.1.0IssueImporter/ExporterModifies the import process so it will update all references after an import.

9.1.0IssueInstallerModifies the ACM Crash Dump Configuration so that it will change when the ACM Data Directory is changed.

9.1.0IssueOPC ItemsCorrects Communication Statistics counter values.

9.1.0IssueOPC ItemsCorrects an error that cleared the item's last value when quality was "Last Known Value".

9.1.0IssueOPC UACorrects an issue that rejected items with square brackets around the device object name.

9.1.0IssueOPC UACorrects an issue that caused multiple address space nodes to be created for the same item if a client did not include the namespace index in the item name.

9.1.0IssueOPC UACorrects an error that resulted in an "out of bounds" error message when a client reinitialized a monitored item list.  Corrects an issue that prevented monitored items from updating for nodes of data type 'signed byte'.  Corrects an error that could return a "Service Fault - BadNotSupported" error message when creating a second monitored item for a node with data type 'signed byte'.

9.1.0IssueOPC UACorrects an issue that prevented monitored items from being created in the Server address namespace.

9.1.0IssueProtocols: Base ProtocolRemoves a duplicate warning message in log files about Item Data and Item Update that appeared when a demand timed out.

9.1.0IssueProtocols: Base ProtocolAdds validation to the device "Connect String" property to disallow non-numeric characters in the IP Port number.

9.1.0IssueProtocols: Base ProtocolCorrects an issue that prevented the Archive Limits "Limit First Collection" settings from being applied when assigning an Archive Limit object after having collected history and reset the pointer.

9.1.0IssueProtocols: Benchmark ProtocolCorrects an issue that incorrectly processed a sub-command 11 when a field item data index was present in the item.

9.1.0IssueProtocols: DNP3 ProtocolAdds support for Vinson Transactional Logs.

9.1.0IssueProtocols: DNP3 ProtocolCorrects an issue that prevented the "Use meter config from device" option from being used during publishing. *Effect On Published Output: The correct meter configuration will be published based on the "Use meter config from device" checkbox.X
9.1.0IssueProtocols: DNP3 ProtocolCorrects an issue that could prevent meter configuration file items from being read after re-checking the "Use meter config from device" option. This could occur when going from using the meter config from the device, to using the advanced meter config, and back again while the meter configuration file from the first setting was still valid.

9.1.0IssueProtocols: DNP3 ProtocolACM will process records that exist in a history record file, even when the sequence number and record count are not the same as those used to open the file.  The sequence and record count mismatch can occur when the device detects and removes corrupted records from the file.  Corrects an issue with using the value of a DNP3 binary item as an enumeration for meter configuration record values. *Effect On Published Output: Corrects publishing incorrect information to meter configuration records, and not retrieving available history records.X
9.1.0IssueProtocols: FlowX ProtocolCorrects the history map validation to treat records with the same EFMID, MeterID and Period as duplicates.

9.1.0IssueProtocols: GE SRTP ProtocolPrevents a memory leak in GE SRTP protocol.

9.1.0IssueProtocols: GE SRTP ProtocolModifies the GE SRTP driver so a "No meter assigned for device" message will not appear when polling a device for which you are not collecting history.

9.1.0IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that prevented audit trail items set to register address 255 from being published when the field was configured in a configurable archive as a 'Value' field. *Effect On Published Output: Audit trail items set to address 255 will now be published if configured as a 'Value' field in the configurable archive object record set.X
9.1.0IssueProtocols: Honeywell - Mercury ProtocolAdds the alarm description in the alarm record output for non EC350 devices. *Effect On Published Output: alarm descriptions will be published for non-EFM alarms.X
9.1.0IssueProtocols: Honeywell - Mercury ProtocolModifies the driver so the demand item will be updated during a cry out after triggering a continuous scan.

9.1.0IssueProtocols: Honeywell - Mercury ProtocolCorrectly assign units for items 910 and 911 in Audit Trail record when used as meter1. *Effect On Published Output: The correct unit will be published for 910 and 911 if the Audit Trail record is used as meter 1.X
9.1.0IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that could prevent a meter's configuration from being uploaded if the sign-on sequence failed during a history upload and a retry is attempted by ACM.

9.1.0IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that could cause the polling sequence to an RTU to get out of sync with the RTU resulting in an Invalid Command Error response during sign-on sequence.

9.1.0IssueProtocols: Honeywell - Mercury ProtocolPrevents a possible invalid value from appearing in the PGASOutputOptions property.

9.1.0IssueProtocols: Honeywell - Mercury ProtocolRemoves the "Change Access" capability for Honeywell Mercury EC350 & ERX350 as it is unsupported by these devices.

9.1.0IssueProtocols: Micro MP3 ProtocolCorrects an issue that prevented the "Contract Hour" from being polled correctly which resulted in the value always being 0 on the Archive Management tab. *Effect On Published Output: Contract hour is now polled correctly and published for Micro MP3 devices.X
9.1.0IssueProtocols: Modbus ProtocolCorrects an error that occurred when writing to array item using common Modbus item modifier 'IS'.

9.1.0IssueProtocols: Omni Modbus ProtocolPrevents a Viscosity event in Omni 7000 devices from returning an abnormal code.

9.1.0IssueProtocols: Omni Modbus ProtocolAdds the Calculation Method for the Omni 7000 liquid meter to the published output. *Effect On Published Output: The Calculation Method will now be published for Omni 7000 liquid meters.X
9.1.0IssueProtocols: Omni Modbus ProtocolCorrects an issue that could cause an exception while processing an Omni 3000/7000 alarm record.

9.1.0IssueProtocols: Possibly multiple protocolsAdds all Batch Record field identifiers and Liquid Product field identifiers to the selection list in the Archive Field Configuration Record Collection form.

9.1.0IssueProtocols: ROC ProtocolAdds DATABASE.TOTAL_YD back to the OPC browsing list.

9.1.0IssueProtocols: ROC ProtocolCorrects an issue that caused the GCWrite to write to incorrect TLPs if the GCWrite was executed before ROC meter configuration was read.

9.1.0IssueProtocols: ROC ProtocolCorrects an issue that occasionally prevented the driver from determining the appropriate series when the "Do not switch ROC automatically series" was unchecked.

9.1.0IssueProtocols: ROC ProtocolCorrects an issue that left an invalid item in the poll message after an "Invalid TLP" error code.

9.1.0IssueProtocols: ROC ProtocolCorrects an issue where ROC FB103's were being polled as 503's resulting in missing values and no extended records. *Effect On Published Output: Corrects an issue where ROC FB103's were being polled as 503's resulting in missing values and no extended records.X
9.1.0IssueProtocols: ROC ProtocolAdds a field to the "Device" tab labeled "Schedule Reinitialization" to schedule the Reinitialize command.

9.1.0IssueProtocols: ROC ProtocolUpdates the Internal Archive Map Details pop-up to list EFM Fields according to meter type.  The button to view this list is found on the "Archive Collection" tab.

9.1.0IssueProtocols: SCADAPack ProtocolCorrects an issue that prevented the Scadapack driver from updating the status of a GC Write request if the request failed due to a Comm error.

9.1.0IssueProtocols: SCADAPack ProtocolPrevents a partial meter record from being published if it is missing a Contract Hour. *Effect On Published Output: Partial meter config records that are missing the Contract Hour will not be published.X
9.1.0IssueProtocols: Siemens ProtocolCorrects an issue with Byte Bit offsets that caused returned and written values to be off by one index.

9.1.0IssueProtocols: Totalflow ProtocolCorrects an issue where a time sync and history request will fail due to having the same priority schedule.

9.1.0IssueProtocols: Totalflow ProtocolModifies the driver to use the configuration value read from the device for the "Has Default Temperature" field instead of a fixed value. *Effect On Published Output: The meter configuration field "Has Default Value" will display the meter's configured value.X
9.1.0IssueProtocols: Totalflow ProtocolCorrects the driver so it will not collect duplicate alarm Records during log period collection. *Effect On Published Output: Duplicate alarm records will not be published.X
9.1.0IssueProtocols: Totalflow ProtocolAdds 'Double' data type support for Totaflow register read and write.

9.1.0IssueProtocols: Weatherford ProtocolCorrects an issue that could cause ACM to stop running if the driver received an unexpected response packet to an FC16EX card buffer upload request.

9.1.0IssueProtocols: Weatherford ProtocolCorrects an issue that could cause the event directory upload to never cease running if the event buffer on the controller was completely full.

9.1.0IssuePublishingIncreases the size of the variables in asi_spgetPublisherFilteredObjects to varchar(max) to process large filters. Note: After this fix, there is still a SQL Server limitation to varchar(max).  If this error is still seen after DB Version 42, the filter will need to be modified.

9.1.0IssuePublishingAdds logging to the Database output type to show if a transaction was committed or rolled back to show the transaction completed.

9.1.0IssuePublishingAdds the field name and unit of measure to the message that is logged when the publisher cannot validate an event.

9.1.0IssuePublishingCorrects the error that resulted in an "Implicit conversion from data type datetime to real is not allowed." message when publishing a sample date to the FLOWCAL Transaction Queue. *Effect On Published Output: The sample date value from a DNP3 FBx device can now be published.X
9.1.0IssuePublishingCorrects the conversion for the Meter Access Date, Cold Start Date, Warm Start Date and Sample Date which are datetime fields but stored as a 'real' value in FLOWCAL. *Effect On Published Output: The Meter Access Date, Cold Start Date, Warm Start Date and Sample Date fields may now have data where previously they were incorrect null or 0.X
9.1.0IssuePublishingPrevents a string value from being published as the Contract Hour if an alphabetic character is entered for Contract Hour in the Advanced Meter Config. *Effect On Published Output: The FLOWCAL Transaction Queue will publish a number entered in the Contract Hour of the Advanced Meter Config, and will publish nothing if an alphabetic character is entered.X
9.1.0IssuePublishingAdds a fixed/live temperature indicator as TEMP_SOURCE and a fixed/live pressure indicator as SP_SOURCE to the meter characteristics for the PGAS XML publisher. *Effect On Published Output: The PGAS XML output will include fixed/live temperature and fixed/live pressure flags in the meter characteristics element if the protocol driver provides them.X
9.1.0IssuePublishingIncludes the values of the User01, User02, and User03 fields from the Details tab, as well as the External GC Reference and External Meter Reference values in the published output. *Effect On Published Output: The User01, User02, User03, External GC Reference and External Meter Reference properties will now have values in the published output.X
9.1.0IssueReportsPrevents extraneous logs from being written when saving edits to scheduled reports.

9.1.0IssueReportsThe script to update the database to version 42 will rebuild the Referenced Objects list which is used by the Orphaned Objects report.  A manual update script is also available if this needs to occur in a database earlier than version 42.

9.1.0IssueReportsAdds support for all of the following report formats to both manually run reports and scheduled reports:  CSV, HTML, PDF, XLS, XLSX, & TEXT.

9.1.0IssueReportsCorrects the Scheduled Report form for the Missing Daily Archive Records to show the saved start and end date parameters when editing the form.

9.1.0IssueServer MonitorModifies the History Deletion value displayed in the Task Summary field when creating a new ACM database to show HH:MM.

9.1.0IssueServer MonitorCorrects the Write Timeout property of "Gas Analysis Writes Retry" to accept values in the range of 30 to 600 seconds.

9.1.0IssueServer MonitorModifies the password requirements for the database user in ACM Monitor to prevent semi-colons.

9.1.0FeatureClient ApplicationAdds a new "right-click" menu option labeled "Navigate To Object" to an object tab that will locate the opened object in the configuration tree.

9.1.0FeatureClient ApplicationAdds a row number to the Dashboard grid.

9.1.0FeatureConnections: UDP BSAP ConnectionModifies ACM to ignore the UDP error code 'WSAECONNRESET' in UDP BSAP.

9.1.0FeatureDNP3 ProtocolAdds the fields KFactor13 - KFactor20 and Frequency13 - Frequency20 to the publisher and the Meter Configuration object. *Effect On Published Output: These fields will be added to the published meter configuration record if FBx meter config files are used and contain these fields.X
9.1.0FeatureDNP3 ProtocolAdds the field VersionNumber to the Meter Configuration object. *Effect On Published Output: These fields will be added to the published meter configuration record if FBx meter config files are used and contain these fields.X
9.1.0FeatureDNP3 ProtocolPublishes the fields KFactor1 - KFactor20 and Frequency1 - Frequency20 from the meter config file read from the DNP3 FBx device. *Effect On Published Output: These fields will be added to the published meter configuration record if FBx meter config files are used and contain these fields.X
9.1.0FeatureGeneralAdds a new Sync Read Timeout property to the $Server object Server tab to establish the lengh of time (in milliseconds) the server should wait for a Sync Read to time out.

9.1.0FeatureMobile PortalAUTOSOL has released the Mobile Portal.

9.1.0FeatureOPC UAAdds a new element to the configuration file named "TraceMasks" to control the message logging output from the OPC UA Stack.  More information regarding the use of the new element can be found in Appendix B of the OPC UA User Guide: https://autosoln.atlassian.net/wiki/spaces/ACMDOCS/pages/1596359214/Appendix+B+Configuration+File

9.1.0FeatureOPC UAAdds support for writing to array type items in ACM.

9.1.0FeatureOPC UAAdds configurable server properties MaxNodesPerWrite and MaxMonitoredItemsPerCall.

9.1.0FeatureOPC UAIntegrates the OPC UA .NET Standard Stack Version 1.4.370.12 from OPC Foundation which fixes the following cybersecurity vulnerability: CVE-2022-33916.X
9.1.0FeatureProtocols: ControlLogix ProtocolUpdates the driver so it can communicate with a device running ControlLogix firmware Rev34.

9.1.0FeatureProtocols: DNP3 ProtocolAdds a modifier &SECONDS to the DNP3 FBx protocol to return seconds elapsed since January 1st, 2000 at 12:00:00 AM.

9.1.0FeatureProtocols: DNP3 ProtocolAdds a new EFM Option, "Publish all meter config fields" to the Archive Collection tab.  When selected, ACM will publish all fields whether or not they have values. *Effect On Published Output: If this option is checked, all meter config fields will be published.  When unchecked, only meter config fields with data will be published.X
9.1.0FeatureProtocols: E-Lite Modbus ProtocolAdds support for the Dynamic Flow Computer's E-Lite Protocol.  This includes the ability to perform a TimeSync command, read and write to registers, and retrieve history, alarm, events and meter configuration information.

9.1.0FeatureProtocols: Honeywell - Mercury ProtocolAdds the ability to include "zero value" bytes to the device wake-up message.  The new field is labeled "Message Nulls" and is found on the Device tab and can be used to stabilize the connection before the 04 byte is sent.

9.1.0FeatureProtocols: Honeywell - Mercury ProtocolAdds a new feature to allow a time sync to be performed on RTU call-in.

9.1.0FeatureProtocols: Kimray ProtocolAdds additional items for the AutoTune/AutoRecovery command for read and write.

9.1.0FeatureProtocols: ROC ProtocolAdds more details to the logging information when the "Log EFM Upload Progress" option on the "Device" tab is checked.

9.1.0FeatureProtocols: ROC ProtocolAdds support for Emerson's new enhanced security released in the following firmware versions: FB107 version 2.0, ROC 800L version 1.70,  ROC 800 version 3.90.

9.1.0FeatureProtocols: ROC ProtocolAdds the Software Version to the meter configuration collection. *Effect On Published Output: The Software Version will now be populated in CFX output.X
9.1.0FeatureProtocols: ROC ProtocolAdds a new option to the "Device" tab labeled "Device is an FB107 with firmware version 2.0 or higher" that must be checked to collect history on FB107 devices with Firmware 2.0+.

9.1.0FeatureProtocols: ROC ProtocolAdds an option to the "Device" tab labeled "Collect history on a ROC with no configured meters (non-RocPlus)" to collect history from devices with no meters assigned.  This feature is not intended for use with the ROC800 series. *Effect On Published Output: When the new option is selected, history will be published for devices with no meters configured.X
9.1.0FeatureProtocols: ROC ProtocolAdds support for Vinson Haul Logs, Vinson Cyclic Logs and Vinson Gas Lift Logs in 107, 80X and 800L series ROC devices.

9.1.0FeatureProtocols: ROC ProtocolAdds an option "Store events only with associated meters" to only publish calibration events with their associated meters. *Effect On Published Output: If the option is turned on, calibration events in ROC800 will only be published to the associated meters.X
9.1.0FeatureProtocols: ROC ProtocolAdds the ability to configure, by meter, which TLPs are written to on GC Write activities.

9.1.0FeatureProtocols: SCADAPack ProtocolAdds an option to the "Archive Collection" tab labeled "Publish Density to Observed Density with Liquid Meters". *Effect On Published Output: If the new option is checked, the Density value will be published to Observed Density for Liquid Meters.X
9.1.0FeatureProtocols: SCADAPack ProtocolUpgrades the SCADAPack driver to support 20 meters.

9.1.0FeatureProtocols: Totalflow ProtocolAdds "Attached to Stream", "Stream Id" and "Fixed Analysis on Error" as Meter Characteristics that can be published. The fields for these characteristics can be set on the Archive Collection tab. *Effect On Published Output: If configured, "Attached to Stream", "Stream Id" and "Fixed Analysis on Error" will be included in the published output.X
9.1.0FeatureProtocols: Weatherford ProtocolUpdates the driver so that an OPC Sync Read of a card buffer array item will cause an immediate upload of that card buffer.

9.1.0FeatureReportsAdds the ability to send scheduled reports to multiple individual emails without the need for a group email account. Email addresses must be separated by a comma.

9.1.0FeatureSecurityAdds the ability to configure, in seconds, the inactivity timeout period. The new option, "Inactivity Timeout" is on the "Security Tab" and only applies when "Enable ROC Login" is checked.

9.1.0FeatureServer MonitorAdds a new column in ACM Monitor Status view showing the Startup Type (i.e. Manual, Automatic or Disabled) for each process.

9.1.0FeatureServer MonitorProvides the ability to change the Startup Type for all ACM processes within the ACM Monitor Status View tab.

9.1.0IssueProtocols: Honeywell - Mercury ProtocolCorrects the alarmType register value for all available Mercury registers to display all digits. *Effect On Published Output: Field5 will no longer be included in the published output.X
9.1.0IssueProtocols: Honeywell - Mercury ProtocolRemoves the extraneous 'Field5' field from the alarm Record. *Effect On Published Output: Field5 will no longer be included in the published output.X
9.1.0IssueProtocols: Honeywell - Mercury ProtocolA Time Sync operation will now cause the Call-in Schedule to be set on the RTU when the protocol option "Set call-in schedule after regular polls" is enabled.

9.1.0IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that caused the RTU call-in to not be acknowledged when no device protocol call-in options were enabled.

9.1.0IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that could cause the next Call-in Schedule to not be set on the RTU when certain combinations of device protocol call-in options were enabled.

9.1.0IssueOPC UAAdds an option that allows the OPC UA server to connect to and disconnect from asiData when a client app connects and disconnects.  This option is on the Properties tab of the OPC UA Configuration in ACM Monitor and is labeled "Only Connect To asiData When There Are Active Client Sessions".

9.1.0IssueOPC UAAdds functionality to allow the OPC UA server to start asiData when a client app connects.

9.1.0IssueReportsCorrects an issue in the Scheduled Reports that caused the $$CurrentDay$$ or $$CurrentHour$$ tokens to be incorrectly calculated in Throughput reports.

9.1.0IssueReportsCorrects an issue in the Scheduled Reports form that prevented the Save button from being enabled after editing the connection.

9.1.0IssueReportsModifies the "Configuration Changes for a Device" report to filter to only Device type objects.

9.1.0IssueReportsAdds a new report titled "Configuration Changes for an Object" to search for configuration changes for any object type.

9.1.0IssueServer MonitorAdds the newest Microsoft OLE DB Driver 19 to the available database providers in ACM Monitor. This provides additional encryption options for the connection.  More information can be found in the User Guide.

9.1.0IssueServer MonitorAdds a button to view the connection string.

9.0.1IssueACM ServerCorrects an issue that prevented encrypted channel communication between an ACM client and server when the client and server components are on different computers.

9.0.1IssueACM ServerCorrects small memory leaks in Flow Automation, Honeywell Mercury, and Totalflow protocols.

9.0.1IssueArchive ManagementThe "Device Id" column in Archive Management now shows the device's object id.

9.0.1IssueBulk ManagerNo longer moves Import files to the Import Failed folder after a SQL Timeout.  Instead they will remain in the Import folder.

9.0.1IssueClient ApplicationRemoves the "Retrieve History", "Delete History for Device" and "Republish Device Records" commands from the right-click menu of Real-Time Only devices.

9.0.1IssueClient ApplicationCorrects an issue on the "OMNI" tab of an OMNI 7000 device that prevented a user from properly typing a value into the "Password" and "Register Block Read Path" text boxes.

9.0.1IssueClient ApplicationCorrects an issue that caused the Logger and Queue tabs to go blank when a large number of object tabs were open in multiple ACM Clients.

9.0.1IssueClient ApplicationCorrects an issue when creating a new Port Object that prevented the Port Type from being changed after canceling out of the folder location screen.

9.0.1IssueClient ApplicationPrevents the Edit Multiple Objects grid from re-sorting the data while a user is typing a value into a cell.

9.0.1IssueConfiguration DatabaseCorrects an issue in SQLUpdate_39.sql that prevented the ACM database from upgrading to DBVersion 39 and above on a SQL Server with the default collation set to "SQL_Latin1_General_CP850_BIN".

9.0.1IssueConfiguration DatabaseIncreases the size of the LastUpdateUser column in tblProperties and tblObjects, and the size of CfgUser in tblChanges, to nvarchar(100).  Note: If the tables are being replicated, this will not run automatically and instead can be run via the Manual Script feature in ACM Monitor.

9.0.1IssueGeneralCorrects a memory leak that occurs when logging "data sent to client" on items in the OPC UA interface.

9.0.1IssueOPC UAIntegrates the OPC UA .NET Standard Stack Version  1.4.369.30 from OPC Foundation which fixes the following cybersecurity vulnerabilities: CVE-2022-29862, CVE-2022-29863, CVE-2022-29864, CVE-2022-29865, and CVE-2022-29866.X
9.0.1IssueProtocols: Base ProtocolCorrects an issue that prevented the PctGoodTries and PctBadTries statistic items from being correctly updated when a connection was dropped before a message could be sent.

9.0.1IssueProtocols: Base ProtocolPrevents queuing an additional Demand after Demand is poked to trigger a continuous scan during cry out.

9.0.1IssueProtocols: BSAP ProtocolCorrects an issue that caused the driver to ignore the previous position and retrieve all history when the "Disable duplicate record deletion" option was selected.

9.0.1IssueProtocols: BSAP ProtocolPrevents a crash from occurring when the Field Configuration has not been assigned and the device cannot be reached.

9.0.1IssueProtocols: DNP3 ProtocolCorrects an issue so that alias items are added correctly via browsing in an OPC client.

9.0.1IssueProtocols: DNP3 ProtocolCorrects an issue that caused incorrect meter configuration values for VersionNumber, CalculationMethod and HeatingValueUnits to be published when using meter config file read from FBx device. *Effect On Published Output: The values for VersionNumber, CalculationMethod and HeatingValueUnits will be published correctly.X
9.0.1IssueProtocols: DNP3 ProtocolChanges the dropdown list that selects the meter run into a numeric updown control in the Meter Runs tab.

9.0.1IssueProtocols: Flow Automation ProtocolCorrects an issue that caused YesterdayFlowTime and YesterdayFlowEnergy to be incorrectly retrieved when the "Retrieve yesterday flow time or energy using history message" option was checked.

9.0.1IssueProtocols: Honeywell - Mercury ProtocolCorrects a potential memory leak.

9.0.1IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that prevented the Unit types for Pressure and Temperature audit record fields from being published for an ER type device. *Effect On Published Output: For ER type devices, the Units for Temperature and Pressure fields will now be published.X
9.0.1IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that could cause EFM audit records to be skipped if comm failure occurred during upload.

9.0.1IssueProtocols: Modbus ProtocolCorrects the default data type for BlockStart-BlockEnd values to unsigned and adds an "S" item conversion to allow values to be output as signed.

9.0.1IssueProtocols: Omni Modbus ProtocolCorrects an issue that prevented subsequent archives from being requested after processing the GC archive for Archive 1.

9.0.1IssueProtocols: Omni Modbus ProtocolPrevents a crash from occurring when polling raw data upload.

9.0.1IssueProtocols: ROC ProtocolDisplays the correct log message type in the logger when the "Items in message" log option is enabled.

9.0.1IssueProtocols: ROC ProtocolNo longer updates the item quality when the "test" of the primary connection fails when using the Auto Recover feature.

9.0.1IssueProtocols: ROC ProtocolCorrects an issue in detecting the ROC model type that prevented ROC history collection settings from updating properly.

9.0.1IssueProtocols: Totalflow ProtocolCorrects an issue that prevented LastHourlyRecord/1 from being initialized correctly with the latest hourly record time stamp.

9.0.1IssueProtocols: Totalflow ProtocolCorrects an issue that occurred when the field device handles a request for a history record at the "maximum position" by returning more than one record.

9.0.1IssueProtocols: Totalflow ProtocolPrevents a poll on the primary connection from switching to the secondary connection when an item with the secondary connection specifier failed to poll.

9.0.1IssueProtocols: Totalflow ProtocolCorrects an issue that prevented the daily record from being collected when using the "number of days" method in the DB2 protocol.

9.0.1IssueProtocols: Weatherford ProtocolCorrects an issue that prevented card data from publishing to a database when the number of data points in the card set exceeded the maximum column count of the table. *Effect On Published Output: When publishing card data using Function Code 25, the position/load data pair field names now starts with "Position0" and "Load0" for each individual stroke record in the card set as opposed to the field name index continuing to increment across the entire card set.X
9.0.1IssuePublishingPrevents the asiPublish process from hanging when asiData is being shut down.

9.0.1IssuePublishingCorrects an issue that prevented FPV Method change events from publishing to the FLOWCAL Transaction Queue. *Effect On Published Output: Events for changing the FPV Method value will now publish correctly to the FLOWCAL Transaction Queue.X
9.0.1IssuePublishingCorrects a PGAS XML publishing issue that created an unnecessary transaction with an empty 'METER' element.

9.0.1IssuePublishingCorrects an issue that stopped publishing to the FLOWCAL Transaction Queue when a record had an invalid future timestamp.

9.0.1IssueReportsLogs the query of a scheduled report when the "Report Logging" option is enabled.

9.0.1IssueReportsCorrects an issue that prevented users from requesting unlimited records when running reports.

9.0.1IssueServer MonitorCorrects an issue in the ACM Database Safe Mode backup that caused the backup to fail if there are orphaned properties or items for a device that does not exist.

9.0.1IssueServer MonitorPrevents an exception in the Server Monitor that could occur when retrieving ACM license request information when FIPS is enabled in the Group Policy.

9.0.1IssueToolsCorrects an issue that could cause one OPC item to replace a previous OPC item in the ACM memory. This only affects the 64-bit version of ACM.

9.0.1IssueBase ProtocolCorrectly updates PctBadTries and PctGoodTries if the connection fails before the message can be sent.

9.0.1IssueBase ProtocolCorrectly updates the port PollAttempts counter when an external interruption occurrs.

9.0.1IssueDNP3 ProtocolAdds support for new objects, parameters, measurements, units and error codes in Emerson FBx firmware release version 2.9.

9.0.1IssueDNP3 ProtocolHandles alarm event records that occur when the device is configured for BSAP Combined event Log.

9.0.1IssueDNP3 ProtocolUses meter config file from device to publish string events as well as FLOWCAL events to non-Generic meters.

9.0.1IssueDNP3 ProtocolIn cases where this can be detected before polling, does not try to retrieve records from empty or unconfigured archives.

9.0.0IssueACM ServerAdds information to GC Request logging to indicate where a failure occurred.  GC Status updates that do not change rows will return a DB Error status.

9.0.0IssueACM ServerResolves issues related to OPC client browsing when clients use absolute browse paths instead of relative browsing.

9.0.0IssueAPICorrects an issue in the API which reported that "Server" objects are creatable.

9.0.0IssueClient ApplicationThe Add/Select object window will now retain its size when closed and reopened.

9.0.0IssueClient ApplicationCorrects various forms throughout ACM where fields and buttons were enabled when they shouldn't have been.

9.0.0IssueClient ApplicationCorrects an issue that occasionally caused an incorrect command name to be logged in the database.

9.0.0IssueClient ApplicationCorrects the message regarding the maximum number of archive records that can be published from 1000 to 5000 to match the actual functionality.

9.0.0IssueClient ApplicationCorrects the tab order on the "Database" tab of the configuration form of the $Server object.

9.0.0IssueClient ApplicationPrevents ACM Configuration from attempting to use an http port when connecting to ACM if one has not been configured.

9.0.0IssueClient ApplicationDisplays a new error message when an object name contains a carriage return in the name.

9.0.0IssueClient ApplicationPrevents invalid data from being saved by disabling the Save button when text is deleted from a required field and when invalid data is entered.

9.0.0IssueClient ApplicationCorrects an issue which caused ACM to crash after renaming a device, then renaming its meter to the same name, but saving changes to the meter before saving the device.

9.0.0IssueConfiguration DatabaseAdds a setting in ACM Monitor called "Keep Meter History".  By default this is set to true and ACM will continue to keep meter record history as in previous versions of ACM.  If this is unselected, ACM will no longer move meter records into history, and and ACM will only have current meter records.

9.0.0IssueConfiguration ServerChanges the default value for deleting old history to "Disabled".

9.0.0IssueLoggingCorrects an issue that caused messages to be split into multiple lines in the log file.

9.0.0IssueMQTTCorrects an issue with Detail Items not showing up correctly in an OPC browse.

9.0.0IssueOPC ItemsCorrects an issue that prevented Detail Items from displaying correctly in an OPC browse.

9.0.0IssueProtocols: Base ProtocolChanges the Quality of Extended Items to "Bad" when a device is disabled and "Good" when the device is enabled. This change affects the ROC, Totalflow, Honeywell Mercury, ControlLogix and Modbus Devices.

9.0.0IssueProtocols: Base ProtocolCorrects an issue that could prevent a device from returning to its regular polling schedule if its alternative schedule was disabled while the device was actively polling on that alternative schedule.

9.0.0IssueProtocols: Benchmark ProtocolCorrects an issue related to writing to multiple items at once that could cause asiData to crash.

9.0.0IssueProtocols: BSAP ProtocolCorrects an issue that prevented the item value from saving for upload pointer and time sync item reads.

9.0.0IssueProtocols: ControlLogix ProtocolCorrects an issue in the "Processor Slot Number" field on the device tab that allowed out of range values to be entered.  The valid range is 0 to 255.

9.0.0IssueProtocols: DNP3 ProtocolCorrects problems with poll cycle interrupts and DNP3 message sequences that shouldn't be interrupted.

9.0.0IssueProtocols: Flow Automation ProtocolCorrects an issue that caused duplicate factor events to be published to the FLOWCAL Transaction Queue, which caused the publisher to fail.

9.0.0IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that caused gaps to occur in history records after an ACK message timed out. Now, instead of skipping to the next record, the driver will attempt to recollect the previous record.

9.0.0IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that could cause an access violation error when certain noise bytes are received in a poll response.

9.0.0IssueProtocols: Honeywell - Mercury ProtocolAdds a new informational message when time synchronization is completed.

9.0.0IssueProtocols: NGCTT ProtocolCorrects an issue that caused history polling to terminate when 10 04 bytes were returned from a device in the middle of polling.

9.0.0IssueProtocols: ROC ProtocolCorrects an issue where events would fail to poll and publish. *Effect On Published Output: Yes. Previously omitted event records may now be polled and published.X
9.0.0IssueProtocols: ROC ProtocolROC Validation of raw TLP OPC tags now takes into account the number and types of meters configured on the device before it attempts to poll them.

9.0.0IssueProtocols: ROC ProtocolCorrects incorrect event mapping for history segment changes in the ROC800 devices. *Effect On Published Output: ROC800 events for history segment changes are output correctly via CFX and Transaction Queue publishers.X
9.0.0IssueProtocols: ROC ProtocolCorrects an issue where mapping and combining points from different segments caused partial records when the segment pointers are misaligned. *Effect On Published Output: Complete records will be published when mapping and combining points from different segments, even when the segment pointers are misaligned.X
9.0.0IssueProtocols: Romet-Adem ProtocolCorrects an issue that could cause incorrect meter configuration values when using the RD command to read register values after a timeout occurs.

9.0.0IssueProtocols: SCADAPack ProtocolModifies the driver to use the correct registers for reading and writing heating value and gas density value.

9.0.0IssueProtocols: SCADAPack ProtocolCorrects an issue that caused GC Write to fail for gas coriolis meter runs on controllers running RealFlo 6.95 or greater.

9.0.0IssueProtocols: SCADAPack ProtocolCorrects an issue that could cause an incorrect pipe material to be published. *Effect On Published Output: The correct value for Pipe Material will be published.X
9.0.0IssueProtocols: Scancom ProtocolCorrects an issue that prevented "Trusted Log In" from being enabled once it had been disabled.

9.0.0IssueProtocols: Scancom ProtocolChanges the "Read Only" state on FRDM items to reflect Barton documentation.

9.0.0IssueProtocols: Scancom ProtocolCorrects an issue when writing to multiple items at once that caused the message to be too large for the PLC to process.  This resulted in no response and communication failure.

9.0.0IssueProtocols: Teledyne CA ProtocolCorrects an issue in the driver that could prevent items of higher cards and points from being polled, which resulted in invalid item values.

9.0.0IssueProtocols: Totalflow ProtocolAdds the Trend Record Type to the trends tab form view. It previously only existed in the Property Grid view.

9.0.0IssueProtocols: Totalflow ProtocolCorrects an issue that caused the "Use FT" and "Use FB" event values to be incorrectly formatted when publishing to CFX or Transaction Queue. *Effect On Published Output: The "Use FT" AND "Use FB" event values will be correctly formatted when publishing to CFX or Transaction Queue.X
9.0.0IssueProtocols: Weatherford ProtocolCorrects an issue that could cause card data reports to publish to the wrong file if more than one device object is configured to use the same meter object.

9.0.0IssuePublishingCorrects the mapping of the SP and DP calibration values so they are output correctly in the PGAS publisher. *Effect On Published Output: The correct values for SP and DP calibration will now be output in the PGAS XML publisher.X
9.0.0IssuePublishingCorrects an issue that prevented the Contract Hour and Contract Day fields from being output to the FLOWCAL Transaction Queue. *Effect On Published Output: The Contract Hour and Contract Day will be output to FLOWCAL Transaction Queue.X
9.0.0IssuePublishingCorrects the default order of archive records in CFX outputs when publishing meters only. *Effect On Published Output: The sort order of CFX output when publishing "Meters Only" will always be by "RecordTS".X
9.0.0IssueReportsCorrects an issue that could cause a scheduled report to run at least once a minute  - ignoring the "sync time".

9.0.0IssueReportsChanges the heading of the 'Date' column in the Configuration Change Reports to 'Date (UTC)'.

9.0.0IssueReportsOptimizes the performance of retrieving and displaying report data.

9.0.0IssueServer MonitorCorrects an issue that prevented services from being started via the Server Monitor if the user for the ACM services did not already have the "Log on as a service" right.

9.0.0IssueServer MonitorProvides a manual update script to change the tblItems ID column to a BIGINT if the column was not upgraded due to the table being replicated.  This can only be run once the tblItems table is removed from the replicated articles.

9.0.0FeatureClient ApplicationProvides the ability to assign multiple alias groups to devices and views.  

9.0.0




9.0.0FeatureClient ApplicationAdds the ability to assign an Interval to Alias Groups.

9.0.0FeatureClient ApplicationAdds the feature to drop down boxes on the Reports tab to automatically filter results while typing.

9.0.0FeatureClient ApplicationAdds a new tool that processes SCADA XML files containing Emerson DNP3 object/parameter names and provides the ability to create, update or replace ACM Alias Group items.

9.0.0FeatureClient ApplicationAdds the Object ID and Description to the search results form.

9.0.0FeatureProtocols: BSAP ProtocolAdds ControlWave signal items to RBE polls.

9.0.0FeatureProtocols: DNP3 ProtocolImplements items to log FBx meter configuration file data.  These items are: LogMeterFileDP/{meter number}, LogMeterFileLinear/{meter number}, LogMeterFileLiquid/{meter number} and LogMeterFileList.

9.0.0FeatureProtocols: DNP3 ProtocolAdds an option "Use history points from device" to the Archive Collection tab's EFM Options to signify to ACM to use the FBx history header to publish history records. *Effect On Published Output: When the "Use history points from device" option is selected, the FBx history header will be used to publish history records.X
9.0.0FeatureProtocols: DNP3 ProtocolAdds an option "Use meter config from device" to the Archive Collection tab's EFM Options to signify to ACM to use the FBx meter config file to: Read the meter list and meter config files from the device to determine which items to read and publish as meter configuration records and read event and alarm records. *Effect On Published Output: When the "Use meter config from device" option is checked, published event, alarm and meter configuration records will be determined by the FBx meter config file.X
9.0.0FeatureProtocols: Honeywell - Mercury ProtocolAdds OPC item "MoveAudit" that provides the ability to move each Audit pointer to the desired date and time.

9.0.0FeatureProtocols: Honeywell - Mercury ProtocolAdds OPC item "ChangeACS" in order for the user to change the access code.  This is only supported for non-350 series controllers.

9.0.0FeatureProtocols: Honeywell - Mercury ProtocolAdds support for using configurable archive records.

9.0.0FeatureProtocols: Micro MP3 ProtocolAdds the ability to poll and publish alternative (non-truck-loading) batch records. *Effect On Published Output: Alternative (non-truck-loading) batch records can now be published.X
9.0.0FeatureProtocols: ROC ProtocolAdds the ability to process ROC 800 Liquid meter data in the GC Write service.

9.0.0FeatureProtocols: ROC ProtocolAdds compressibility (Zs and Zb) to the meter configuration record for Directive 17 Compliance. *Effect On Published Output: The compressibility fields (Zs and Zb) of the meter configuration record will now be published.X
9.0.0FeatureProtocols: ROC ProtocolAdds support for publishing data to Flowcal Ultrasonic Diagnostic area. *Effect On Published Output: Only if customers map the new Ultrasonic EFM IDs to historized points. Existing customers will not be affected.X
9.0.0FeatureProtocols: ROC ProtocolAdds a new PGAS Output option labeled "Map Volume to INDEX_OFF and 0 to INDEX_ON" for PGAS output. *Effect On Published Output: If the new option is used, volume will be published to INDEX_OFF and INDEX_ON will be set to zero in the PGAS output.X
9.0.0FeatureProtocols: ROC ProtocolAdds the ability to collect 'Tap Type' with meter configuration in ROC800 devices. *Effect On Published Output: Publisher outputs will now include 'Tap Type' in the meter configuration.X
9.0.0FeatureProtocols: ROC ProtocolAdds the ability to publish Ultrasonic Data to the FLOWCAL Transaction Queue. *Effect On Published Output: Ultrasonic Data can now be published to the FLOWCAL Transaction QueueX
9.0.0FeatureProtocols: ROC ProtocolAdds the ability to retrieve HART tags for Process Limits for the meter configuration records of ROC 800 gas and liquid devices.  The HART module in ROC FB107 and any older ROC devices (200's, 300's, 500's) is not supported. *Effect On Published Output: If configured in the device, HART tags will be used for Process Limits when publishing meter configuration records.X
9.0.0FeatureProtocols: ROC ProtocolAdds an option to the device tab "Use indicated volume for mass in mass meters." to control whether mass or indicated volume is published as mass for liquid mass meters. *Effect On Published Output: When the new option "Use indicated volume for mass in mass meters." is selected, indicated volume will be published as mass for liquid mass meters.  If not selected, mass will be published.X
9.0.0FeatureProtocols: ROC ProtocolAdds support for V-Cone meters.  A new tab for configuring this has been added between the "Meter Runs" and "History Segments" tabs in the ROC configuration. *Effect On Published Output: V-Cone meter data may now be published.X
9.0.0FeatureProtocols: Weatherford ProtocolAdds a Weatherford 8500 protocol module to communicate with Weatherford WellPilot RPOC, ePic VSD, ePic RPC, M8800, M8750, M2000, M8650, M8500, and EXS-1000 ESP. Other devices that use the same Weatherford/Baker/eProd 8500 protocol, or use protocol simulators, are also supported.

9.0.0FeatureProtocols: Weatherford ProtocolOptimizes the performance for OPC synchronous read from device requests.

9.0.0FeaturePublishingAdds an option to the PGAS XML output type labeled "Create files per record type" to store meter characteristic records separately from other record types. If enabled, meter characteristics records will be stored in their own file. All other record types (volume, alarm, event and quality) will be stored together. *Effect On Published Output: If the new PGAS XML option "Create files per record type" is selected, meter characteristic records will be stored separately from other record types in PGAS XML published outputs.X
9.0.0FeaturePublishingField records of an Archive Field Configuration object can now be selectively configured to be skipped when publishing the EFM record. *Effect On Published Output: Protocols that use a configurable archive object can now be configured to selectively skip EFM record fields when publishing.X
9.0.0FeatureSCADAPack ProtocolAdds support for SCADAPack x70 series RTUs.

9.0.0FeatureSCADAPack ProtocolAdds support for RealFlo 7.0.

9.0.0FeatureSCADAPack ProtocolAdds support for AGA3-2013.

9.0.0IssueConfiguration DatabaseRemoves the logic from the following deprecated stored procedures: asi_spPubNewRecords, asi_spPubNewMeterRecords, asi_spGetHourlyGapsMain, asi_spGetHourlyGaps, asi_spGetHourly, asi_spGetDailyGapsMain, asi_spGetDailyGaps, asi_spGetDaily, asi_spChildObjects, asi_spDeleteOldArchiveRecords, asi_spDeleteOldArchiveRecords2.  The empty stored procedures will remain in the database as replicated stored procedures cannot be "dropped".

9.0.0IssueConfiguration DatabaseModifies the Meter Historization process stored procedure to improve processing speed.

9.0.0IssueConfiguration DatabaseDeletes Meter Record History rows (in tblMeterRecordsHistory) for meters that do not exist in the ACM configuration.

8.2.1IssueACM ServerCorrects a property load error that can occur when processes ACM relies upon aren't available.

8.2.1IssueClient ApplicationCorrects the tool tip message for the Details tab User01 property.

8.2.1IssueClient ApplicationCorrects the checkbox list initial focus issue on multiple tabbed pages

8.2.1IssueClient ApplicationThe date-time parameters in reports will now correctly display the saved date and time when editing a scheduled report.

8.2.1IssueClient ApplicationCorrects an issue that prevented using the "Edit Multiple" feature to edit the Protocol Options on multiple New Honeywell Mercury devices.

8.2.1IssueClient ApplicationRemoves erroneous log messages that were displayed when writing to an item with "ReadUserOnly" disabled.

8.2.1IssueConfiguration DatabaseImproves performance of the Archive Management/Gap Detection Process.

8.2.1IssueConfiguration DatabaseImproves performance of resetting a publisher, both with and without a filter.  Note:  Will be more efficient if appropriate indexes exist on the tables.  Run the manual update script to create missing indexes.

8.2.1IssueConfiguration DatabaseImproves overall publishing performance. Note:  Will be more efficient if appropriate indexes exist on the tables.  Run the manual update script to create missing indexes.

8.2.1IssueConfiguration DatabaseAdds three reports for verifying data and schema integrity. 
-The "Data Integrity Report" returns information regarding potential errors in the configuration.

-The "Frequent alarm and event Report" returns information regarding meters with alarms and events above a given quantity .
-The "Database Schema Integrity Report" returns details about the production schema that does not match the installed ACM version such as missing or mismatched indexes and triggers.


8.2.1IssueConfiguration DatabaseAdds a table to the ACM Database for keeping track of database version history.

8.2.1IssueConfiguration DatabaseProvides a script to create all expected but missing indexes on ACM tables.

8.2.1IssueConfiguration DatabaseModifies the stored procedure that is responsible for deleting archive records to make it more efficient.

8.2.1IssueConnections: Base ConnectionIncreases the Connection Settings Reply Timeout maximum value from two minutes to three minutes.

8.2.1IssueConnections: Serial ConnectionCorrects an issue that prevented saving configuration changes in Serial Ports.

8.2.1IssueConnections: TCP Listen ConnectionCorrects a crash in connection modules that occurred during poll interruption.

8.2.1IssueGC Write ServiceCorrects an issue to prevent GC Write Requests from getting stuck after 32,767 retries when using "slow mode".

8.2.1IssueGeneralCorrects the OPC item ->Server/CfgCount value update when multiple ACMConfig Clients are connected.

8.2.1IssueGeneralCorrects an issue that allowed Async Writes from an OPC client when they should have been blocked.

8.2.1IssueGeneralCorrects an issue that could cause the initial OPC refresh to fail when used by a managed language client.

8.2.1IssueLoggingCorrects a crash in asiLOGSERVER service.

8.2.1IssueProtocols: Benchmark ProtocolCorrects an issue that caused asiData to hang when uploading history from a Benchmark device if the server did not have DST setup.

8.2.1IssueProtocols: ControlLogix ProtocolAdds a new option to "Invalidate read items on Forward Open failures". When selected, the driver will Invalidate read items on Forward Open connection errors that are non-recoverable, resulting in no poll messages with item value updates during that poll cycle attempt. Improved logging details for Forward Open connection errors.

8.2.1IssueProtocols: ControlLogix ProtocolLowers the Timeout Multiplier for CIP connections to help avoid running out of connection resources during rapid polling schedules.

8.2.1IssueProtocols: ControlLogix ProtocolCorrects an issue with Bit offsets for INT data types that stopped getting read updates after being written to with the Verify Writes option enabled.

8.2.1IssueProtocols: ControlLogix ProtocolCorrects an issue where invalid messages present in the buffer could cause validation logic to hang up the polling engine.

8.2.1IssueProtocols: Enron Modbus ProtocolCorrects an issue where EFM configuration requests were being built individually, even when poll block was enabled and registers were within range.  Now these will be built as combined messages for Enron, Kinder Morgan, Prosoft, Scadapack and Scanner1150 Modbus protocol.

8.2.1IssueProtocols: Flow Automation ProtocolModifies the driver to output the correct meter configuration record for Coastal Flow device type.

8.2.1IssueProtocols: FlowX ProtocolProvides missing device destination IP and Port as part of requested message to meet possible firewall rules.

8.2.1IssueProtocols: FlowX ProtocolCorrects an issue that could prevent history collection when not using an alarm map.

8.2.1IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that prevented items from being successfully added during a restart of ACM if the device firmware did not support the new RG command.

8.2.1IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue that prevented messages from being consolidated after items were removed.

8.2.1IssueProtocols: Honeywell - Mercury ProtocolCorrects an issue when writing TS, GCWrite and NextCallinSchedule that prevented the write message from using the configured access code.

8.2.1IssueProtocols: Honeywell - Mercury ProtocolModifies the driver to correctly handle an error returned during an ACK or NAK request so that a poll cycle retry will be triggered.

8.2.1IssueProtocols: Honeywell - Mercury ProtocolModifies several protocols such as the new Mercury protocol and Omni protocol to update meter record time stamp after recollection. *Effect On Published Output: Meter configuration records will be republished after re-collection without requiring a restart of asiData.X
8.2.1IssueProtocols: Modbus ProtocolCorrects an error that prevented using the modbus "block read" item.

8.2.1IssueProtocols: ROC ProtocolCorrects a logger warning message which resulted when some ROC configurations published meter configuration information.

8.2.1IssueProtocols: Scancom ProtocolCorrects an issue with Demand GC message not correctly building for Adept 4.0 message format.

8.2.1IssueProtocols: Scancom ProtocolCorrects an issue with variable length strings in EFM records that resulted in reading incorrect characters from the buffer beyond the record. *Effect On Published Output: Invalid characters from the buffer will no longer be output in a variety of record types.X
8.2.1IssueProtocols: Scancom ProtocolCorrects OPC validation of hardware items so that they will will not be added if parameter and slot are not entered correctly.

8.2.1IssueProtocols: Scancom ProtocolModifies the driver so that items not updated due to an error with an item id in a read are now marked as invalid.

8.2.1IssueProtocols: Siemens S7 ProtocolAdds configuration settings to directly control TSAP values on S7-200 model connections.

8.2.1IssueProtocols: Totalflow ProtocolCorrects the log messages displayed when executing the "Retrieve Meter config during next history poll" and "Reset History (LogPeriod/Daily/Event) Pointer" commands.

8.2.1IssueProtocols: Totalflow ProtocolCorrects an issue in the meter configuration record where multiple sets of duplicated fields were output when using the Number of Days history collection option. *Effect On Published Output: Meter Configuration records will no longer contain multiple duplicate fields.X
8.2.1IssuePublishingCorrects an issue that could cause the FlowCal Transaction Queue publisher to insert a zero into a GC or history field when the field has no value. *Effect On Published Output: Empty GC and history record fields will now be blank instead of displaying a 0 in the Flowcal Transaction Queue.X
8.2.1IssueConfiguration DatabaseModifies the meter historization process to run in a stored procedure instead of a trigger to prevent issues with replication and clustering.

8.2.1IssueConfiguration DatabaseModifies the meter historization process to only keep unique meter FieldData

8.2.1IssueHoneywell - Mercury ProtocolCorrects an issue that resulted in response packet noise byte characters being included in the CRC calculation.

8.2.1IssueHoneywell - Mercury ProtocolCorrects an issue that could result in a failed EFM upload completing with a Successful Poll result.



Release

Category

Type

Text

Affects Published Output

Addresses Security Vulnerability
9.1.2Alias Groups/ItemsIssueCorrects an issue that caused items within an alias group to be internally advised and ready for MQTT publishing by a copied device object, even when the alias group did not have MQTT publishing enabled.

9.1.2APIIssueCorrects an issue that caused the AutoSol.ACM.Config.Client file to not be found when developing using the API in an ASP.NET environment.

9.1.2asiDATAIssueCorrects an error that could occur while saving objects if asiData was disconnected from the SQL Server when using the SQL Driver MSOLEDBSQL version 18.6 or later.  The error messages in ACM addressed by this fix include: "Could not find prepared statement with handle #" and "Procedure {procedurename} has too many arguments specified".

9.1.2asiDATAIssueCorrects an issue that caused an invalid timestamp to occur on Leap Day.

9.1.2Base ConnectionIssueCorrects the failure retry count of polls that occur after a priority interruption.

9.1.2BSAP ProtocolIssueCorrects an issue that caused BSAP Devices to fail to retrieve history over ethernet connections.

9.1.2Bulk ManagerIssueChanges the Bulk Manager so that a file that failed to import due to the process being selected as the "DEADLOCK victim" will stay in the import folder.

9.1.2Bulk ManagerIssueImproves the log messages to contain more details if a SQL failure occurs.

9.1.2Client ApplicationIssueChanges the labels in the Publisher CSV from "Publish Report Records" to "Publish All Report Records" and "Publish Prove Report Records" to "Publish Prove Records". 

9.1.2Client ApplicationIssueRestores the User Preference Activate Alias Tags on Status Tab "Only when Alias Group tags are active" option.

9.1.2Client ApplicationIssueRemoves the unused 'Alarm Service' fields from the ACM Connect to Server Options.

9.1.2Client ApplicationIssueIncreases the character limit of the "Provider String" field to 512 characters for the EFMDB and DB output types.

9.1.2Client ApplicationIssueChanges the default button on the "Delete Objects" dialog to "Cancel".

9.1.2Client ApplicationIssuePrevents spaces from being saved at the beginning or end of the Connect String field.

9.1.2Client ApplicationIssueCorrects sorting for datetime columns in the Dashboard.

9.1.2Client ApplicationIssuePrevents the Config Client from disconnecting from the server when using special characters in the search tool. 

9.1.2Client ApplicationIssueCorrects an issue that could leave items advised and polling when switching between different alias groups on the Status tab of a device configuration form.

9.1.2Client ApplicationIssueCorrects an issue that caused the search to only find matching objects if those objects had a description.

9.1.2Client ApplicationIssueCorrects an issue that caused the search functionality to fail to find matches when there was a leading or trailing space in the search criteria.

9.1.2Configuration DatabaseIssueUpdates the asi_spFrequentalarmandEventReport stored procedure to use the alarmLimitEvent parameter.

9.1.2Configuration DatabaseIssueAdds the table 'EdgeEFMConfigurationErrors' to the ACM database to record errors that may occur when publishing EFM data from the Edge.  These errors will be visible in the 'Error Log Report Last X Days' report.

9.1.2Configuration DatabaseIssueUpdates variables in two stored procedures, asi_spResetPublisherPosition_Filter and asi_spResetPublisherPosition, from INT to BIGINT to allow for very large archive sequence IDs.

9.1.2Configuration DatabaseIssueModifies the "Publish a Device" command on the Publisher Command tab to publish all records, regardless of filter settings.  Previously if the filter was for meters only, it would log "No records published for ObjectId = ### as it is not contained in the filter". This is a database update to the asi_spInsertPublishObjects4 stored procedure. *Effect on published output: When using the "Publish a Device" command from a publisher, all records will be published for that device regardless of filter settings.

9.1.2ControlLogix ProtocolIssueCorrects an issue that prevented the LastPollSuccessTime from updating correctly due to CIP Forward Open errors.

9.1.2DNP3 ProtocolIssueModifies the Move and Reset commands for alarm and event pointers so that they will execute as long as any meter is assigned.

9.1.2DNP3 ProtocolIssueCorrects the DNP3 meter type and calculation method mapping.  Previously 'AGA3-2013' was published as 'AGA3-1992' and 'API 12.2 Volumetric' was published as 'Linear Mass'.  Meter Types 'Ultrasonic' and 'Positive Displacement' were previously empty in published output.  *Effect on published output: The correct calculation method and meter type will now be published.  X
9.1.2DNP3 ProtocolIssuePrevents an OPC Client from activating DNP3 internal items.

9.1.2DNP3 ProtocolIssueCorrects the Gain/Offset scaling in the DNP3 FBx protocol. *Effect on published output: When set in the Archive Field Configuration, the published raw values will be scaled according to the Gain/Offset Scaling formula ItemName{SG:Gain:Offset}.X
9.1.2ExportMDBIssuePrevents ACM from replacing an existing Access database backup file with an empty one if asiData cannot connect to SQL Server.

9.1.2GE SRTP ProtocolIssueExtends the write message to include more than one item write in the same protocol message.

9.1.2Honeywell - Mercury ProtocolIssueCorrects an issue that could cause multiple items to be associated with an RD message when the server was starting.

9.1.2Honeywell - Mercury ProtocolIssueCorrects an issue that caused a Call-in message to be ignored if a low priority write was currently queued.

9.1.2Honeywell - Mercury ProtocolIssueCorrects an issue that caused items that were reported as invalid by the RTU to be added back to poll messages.

9.1.2Honeywell - Mercury ProtocolIssueCorrects an issue that prevented an item write from being sent to device if the write happened during an active poll session.

9.1.2Honeywell - Mercury ProtocolIssueCorrects an issue that could prevent the driver from sending the log on sequence to the RTU if the last poll cycle ended in comm failure.

9.1.2Honeywell - Mercury ProtocolIssueCorrects an issue that caused an incorrect leading/trailing timestamp indicator to be published for Mini-AT, Mini-Max, AccuTest and TurboCorrector devices. *Effect on published output: The correct leading/trailing timestamp indicator will be published.X
9.1.2Honeywell - Mercury ProtocolIssueDecodes G items (1600-1699) for the Mercury EC350 series. *Effect on published output: The correct value for G items will be published.X
9.1.2Honeywell - Mercury ProtocolIssueModifies the 'First Collection Limit' so that the most recent alarm and event Archive records are published instead of the oldest. 

9.1.2Honeywell - Mercury ProtocolIssueCorrects an issue that caused all alarms in the alarm buffer of a Mini-AT to be published on every history upload. *Effect on published output: Only the expected alarms will be published when using the RL command to upload alarms.X
9.1.2Honeywell - Mercury ProtocolIssueModifies the protocol to perform a primary path test before switching from the secondary connection to the primary connection.

9.1.2Honeywell - Mercury ProtocolIssuePrevents the driver from collecting records that are out of the request range.

9.1.2Honeywell - Mercury ProtocolIssuePrevents a possible invalid value from appearing in the PGASOutputOptions property. 

9.1.2Honeywell - Mercury ProtocolIssueCorrects an issue that prevented the Mercury Call-in Schedule from saving the Start, Length, and Interval values.

9.1.2Importer/ExporterIssuePrevents ACM from updating references when the "Cancel" button is clicked from the Import form.

9.1.2Importer/ExporterIssuePrevents an error from occurring when importing a "Connect String" that had a space at the end of the value.

9.1.2Importer/ExporterIssueCorrects an issue encountered while importing Alias Groups with empty record values that prevents the entire Alias Group from getting imported.

9.1.2Item ServerIssueReduces nuisance log messages that appeared while the ItemServer waited for asiDATA to start.  Now the service will wait until asiDATA is running before attempting the IPC connection.

9.1.2Item ServerIssueCorrects an issue that caused MinutesSinceComplete to be incorrectly calculated immediately after DST.

9.1.2Kinder Morgan ModbusIssueImproves the handling of unexpected sequence number and archive reset conditions.

9.1.2LoggingIssueAdds additional information to the logger if asiLogger is unable to retrieve the local time and fails to generate a new file at midnight.

9.1.2Modbus ProtocolIssueAdds missing Modbus Protocol token values for meter configuration records. *Effect on published output: The published output will no longer be missing token values.X
9.1.2MQTTIssueCorrects an issue that sent erroneous DDEATH messages to the MQTT broker when the interval on an alias group changed.

9.1.2MQTTIssueCorrects an issue that caused a partially configured broker to require an ItemServer restart before being able to complete the configuration.

9.1.2OPC UAIssueCorrects the data type of the initial value update for archive 'Move' and 'Reset' items.

9.1.2OPC UAIssuePrevents inactive OPC UA items from getting an internal update.

9.1.2OPC UAIssueCorrects an issue that could prevent items in a new Alias Group from being updated if that contained invalid item names.

9.1.2OPC UAIssueSets the status of a node that represents an ACM item to 'UncertainLastUsableValue' when all monitored items are removed from the node.

9.1.2OPC UAIssueCorrects an issue that prevented a monitored item from being created on an address space node that has a bad status.

9.1.2OPC UAIssueCorrects an issue that caused the 'Restart OPC UA Service' message to be shown when only log flags were changed on the OPC UA configuration dialog.

9.1.2Prosoft ModbusIssueModifies the driver to evaluate the contract hour unit and convert the value accordingly. *Effect on published output: The contract hour will be converted using the correct contract hour unit.X
9.1.2PublishingIssueIn the CFX publishers, if the meter contents change from liquid to gas or vice versa, the CFX file will be renamed to include the current timestamp and a new file will be generated.  Previously the publisher would fail. *Effect on published output: While the data within the CFX file will not change, the file name may change if a meter's content changes from Liquid to Gas or vice versa.X
9.1.2PublishingIssueCorrects an issue that allowed duplicate periodic records to be published to CFX7 and CFX8 files. *Effect on published output: Duplicate periodic records will no longer be published to CFX.X
9.1.2ROC ProtocolIssueRemoves the "Combine data from all segments into the same archive record" option from non-800 RTUs as it is not applicable. Previously, if used erroneously, it could result in a crash.

9.1.2ROC ProtocolIssueCorrects an issue that caused the driver to retrieve all batch records instead of the Batch Archive Limit value.

9.1.2ROC ProtocolIssueCorrects an issue where the tag modifier <TJULIAN> was not functional for 4 byte Julian dates.

9.1.2Server MonitorIssueCorrects an issue that caused the Database Statistics form to return the error message: "Keyword not supported: 'provider' not allowed.".

9.1.2Server MonitorIssueUpdates the support package creator to provide more information regarding what can be included and provide more options to configure the contents.

9.1.2Server MonitorIssueCorrects an issue that caused the wrong "History Deletion Frequency" option to be displayed during create/update database operations via ACM Monitor.

9.1.2Server MonitorIssueModifies the database form in ACM Monitor so that the "Create/Update Database" button cannot be clicked until a provider is selected.

9.1.2Totalflow ProtocolIssueCorrects an issue that prevented Totalflow extended items such as Move Daily and Move event from reverting back to their default value in UA Clients.

9.1.2Totalflow ProtocolIssueIncludes the orifice plate reference temperature value in the meter configuration records for orifice meters using the AGA3-2013 calculation method.  Previously it output 'empty/null'. *Effect on published output: The orifice plate reference temperature will be published for orifice meters using the AGA3-2013 calculation method.X
9.1.2Totalflow ProtocolIssueIncludes additional diagnostic logging when the "Enable message tracing for more logging information" option is selected.

9.1.2Totalflow ProtocolIssueCorrects an error that could use the wrong 'remote meter index' when sending GC data to device.

ACM 9.1Protocols: ROC ProtocolFeatureAdds a new option to the "Device" tab labeled "Device is an FB107 with firmware version 2.0 or higher" that must be checked to collect history on FB107 devices with Firmware 2.0+. 

ACM 9.1Protocols: ROC ProtocolFeatureAdds an option to the "Device" tab labeled "Collect history on a ROC with no configured meters (non-RocPlus)" to collect history from devices with no meters assigned.  This feature is not intended for use with the ROC800 series. *Effect On Published Output: When the new option is selected, history will be published for devices with no meters configured.

ACM 9.1Protocols: ROC ProtocolFeatureAdds support for Vinson Haul Logs, Vinson Cyclic Logs and Vinson Gas Lift Logs in 107, 80X and 800L series ROC devices. 

ACM 9.1Protocols: ROC ProtocolFeatureAdds an option "Store events only with associated meters" to only publish calibration events with their associated meters. *Effect On Published Output: If the option is turned on, calibration events in ROC800 will only be published to the associated meters.X
ACM 9.1Protocols: ROC ProtocolFeatureAdds the ability to configure, by meter, which TLPs are written to on GC Write activities. 

ACM 9.1Protocols: SCADAPack ProtocolFeatureAdds an option to the "Archive Collection" tab labeled "Publish Density to Observed Density with Liquid Meters". *Effect On Published Output: If the new option is checked, the Density value will be published to Observed Density for Liquid Meters.X
ACM 9.1Protocols: SCADAPack ProtocolFeatureUpgrades the SCADAPack driver to support 20 meters. 

ACM 9.1Protocols: Totalflow ProtocolFeatureAdds "Attached to Stream", "Stream Id" and "Fixed Analysis on Error" as Meter Characteristics that can be published. The fields for these characteristics can be set on the Archive Collection tab. *Effect On Published Output: If configured, "Attached to Stream", "Stream Id" and "Fixed Analysis on Error" will be included in the published output.X
ACM 9.1Protocols: Weatherford ProtocolFeatureUpdates the driver so that an OPC Sync Read of a card buffer array item will cause an immediate upload of that card buffer. 

ACM 9.1ReportsFeatureAdds the ability to send scheduled reports to multiple individual emails without the need for a group email account. Email addresses must be separated by a comma. 

ACM 9.1SecurityFeatureAdds the ability to configure, in seconds, the inactivity timeout period. The new option, "Inactivity Timeout" is on the "Security Tab" and only applies when "Enable ROC Login" is checked. 

ACM 9.1Server MonitorFeatureAdds a new column in ACM Monitor Status view showing the Startup Type (i.e. Manual, Automatic or Disabled) for each process. 

ACM 9.1Server MonitorFeatureProvides the ability to change the Startup Type for all ACM processes within the ACM Monitor Status View tab. 

ACM 9.1Alias Groups/ItemsIssueCorrects ACM to use only the $Server alias group if one is assigned.  If an alias group is not assigned to the $Server object, ACM will use the device specific alias groups. 

ACM 9.1APIIssueModifies the API to enforce validation of maximum/minimum values. 

ACM 9.1APIIssueCorrects an issue connecting to ACM when the API is loaded by an unmanaged process. 

ACM 9.1asiBridgeIssueCorrects the Quality of Service used by asiBRIDGE when it publishes MQTT messages. 

ACM 9.1Client ApplicationIssueModifies the "Copy" functionality so that when copying a device, the meter references will not be copied. This prevents multiple devices polling data for the same meters. 

ACM 9.1Client ApplicationIssueCorrects the tool tip message for the Details tab User01 property. 

ACM 9.1Client ApplicationIssueCorrects an issue that caused the Configuration Manager to disconnect from asiData when searching for certain special characters (e.g parantheses). 

ACM 9.1Client ApplicationIssueCorrects an issue in the Scheduled Report form that caused fields using tokens to be reset. 

ACM 9.1Client ApplicationIssueCorrects an issue that prevented  the object tree from reloading when selecting multiple objects via the search tool. 

ACM 9.1Client ApplicationIssueAdds the $Server and $Perf objects to the object tree in "Type View" and "Category View". 

ACM 9.1Configuration DatabaseIssueCorrects casing in asi_spInvokeArchiveSnapshot and asi_spGetPublisherFilterObjects to prevent errors on SQL Servers with extremely strict case defaults. 

ACM 9.1Configuration DatabaseIssueIncreases the size of variables in asi_spGetPublisherFilteredObjects to handle very large filters.

ACM 9.1Configuration DatabaseIssueCorrects an issue in the stored procedure asi_spInvokeArchiveSnapshots that could cause the Archive Management grid to display an incorrect Contract Hour for various protocols. 

ACM 9.1Configuration DatabaseIssueThe script to update the database to version 42 will rebuild the Referenced Objects list which is used by the Orphaned Objects report.  A manual update script is also available if this needs to occur in a database earlier than version 42. 

ACM 9.1GC Write ServiceIssueCorrects the use of the tab delimiter and adds validation for delimiters in the GC Write File Service. 

ACM 9.1GeneralIssueCorrects an issue that caused ACM to wait for an OPC Sync Read request to complete when the target device object had been disabled. 

ACM 9.1GeneralIssueChanges the default DCOM authentication level from 'Connect' to 'Packet Integrity'. An override is available and instructions are found in the ACM and Windows DCOM Hardening section of the user guide.
YES
ACM 9.1GeneralIssueCorrects an issue that could cause an invalid timestamp in an OPC data change update. 

ACM 9.1Importer/ExporterIssueExcludes missing Alias Group references from exported configuration data and ignores missing Alias Group references during configuration import. 

ACM 9.1Importer/ExporterIssueModifies the import process so it will update all references after an import. 

ACM 9.1InstallerIssueModifies the ACM Crash Dump Configuration so that it will change when the ACM Data Directory is changed. 

ACM 9.1Kinder Morgan ModbusIssueCorrects an issue related to archive sequence number resets in Kinder Morgan Modbus. 

ACM 9.1OPC ItemsIssueCorrects Communication Statistics counter values. 

ACM 9.1OPC ItemsIssueCorrects an error that cleared the item's last value when quality was "Last Known Value". 

ACM 9.1OPC UAIssueAdds an option that allows the OPC UA server to connect to and disconnect from asiData when a client app connects and disconnects.  This option is on the Properties tab of the OPC UA Configuration in ACM Monitor and is labeled "Only Connect To asiData When There Are Active Client Sessions". 

ACM 9.1OPC UAIssueAdds functionality to allow the OPC UA server to start asiData when a client app connects. 

ACM 9.1OPC UAIssueCorrects an issue that rejected items with square brackets around the device object name. 

ACM 9.1OPC UAIssueCorrects an issue that caused multiple address space nodes to be created for the same item if a client did not include the namespace index in the item name. 

ACM 9.1OPC UAIssueCorrects an error that resulted in an "out of bounds" error message when a client reinitialized a monitored item list.  Corrects an issue that prevented monitored items from updating for nodes of data type 'signed byte'.  Corrects an error that could return a "Service Fault - BadNotSupported" error message when creating a second monitored item for a node with data type 'signed byte'. 

ACM 9.1OPC UAIssueCorrects an issue that prevented monitored items from being created in the Server address namespace. 

ACM 9.1OPC UAIssueCorrects issue that could cause items to not be added to ACM but be active in the client application when the 'Only connect to asiData when there are active client sessions' property is enabled. 

ACM 9.1Protocols: Base ProtocolIssueRemoves a duplicate warning message in log files about Item Data and Item Update that appeared when a demand timed out. 

ACM 9.1Protocols: Base ProtocolIssueAdds validation to the device "Connect String" property to disallow non-numeric characters in the IP Port number. 

ACM 9.1Protocols: Base ProtocolIssueCorrects an issue that prevented the Archive Limits "Limit First Collection" settings from being applied when assigning an Archive Limit object after having collected history and reset the pointer. 

ACM 9.1Protocols: Benchmark ProtocolIssueCorrects an issue that incorrectly processed a sub-command 11 when a field item data index was present in the item. 

ACM 9.1Protocols: DNP3 ProtocolIssueAdds support for Vinson Transactional Logs. 

ACM 9.1Protocols: DNP3 ProtocolIssueCorrects an issue that prevented the "Use meter config from device" option from being used during publishing. *Effect On Published Output: The correct meter configuration will be published based on the "Use meter config from device" checkbox.X
ACM 9.1Protocols: DNP3 ProtocolIssueCorrects an issue that could prevent meter configuration file items from being read after re-checking the "Use meter config from device" option. This could occur when going from using the meter config from the device, to using the advanced meter config, and back again while the meter configuration file from the first setting was still valid. 

ACM 9.1Protocols: DNP3 ProtocolIssueACM will process records that exist in a history record file, even when the sequence number and record count are not the same as those used to open the file.  The sequence and record count mismatch can occur when the device detects and removes corrupted records from the file.  Corrects an issue with using the value of a DNP3 binary item as an enumeration for meter configuration record values. *Effect On Published Output: Corrects publishing incorrect information to meter configuration records, and not retrieving available history records.X
ACM 9.1Protocols: FlowX ProtocolIssueCorrects the history map validation to treat records with the same EFMID, MeterID and Period as duplicates. 

ACM 9.1Protocols: GE SRTP ProtocolIssuePrevents a memory leak in the GE SRTP protocol. 

ACM 9.1Protocols: GE SRTP ProtocolIssueModifies the GE SRTP driver so a "No meter assigned for device" message will not appear when polling a device for which you are not collecting history. 

ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueCorrects an issue that prevented audit trail items set to register address 255 from being published when the field was configured in a configurable archive as a 'Value' field. Effect On Published Output: Audit trail items set to address 255 will now be published if configured as a 'Value' field in the configurable archive object record set.X
ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueCorrects the AlarmType register value for all available Mercury registers to display all digits. 

ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueRemoves the extraneous 'Field5' field from the Alarm Record. *Effect On Published Output: Field5 will no longer be included in the published output.X
ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueAdds the alarm description in the alarm record output for non EC350 devices. *Effect On Published Output: Alarm descriptions will be published for non-EFM alarms.X
ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueModifies the driver so the demand item will be updated during a cry out after triggering a continuous scan. 

ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueCorrectly assign units for items 910 and 911 in Audit Trail record when used as meter1. *Effect On Published Output: The correct unit will be published for 910 and 911 if the Audit Trail record is used as meter 1.X
ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueCorrects an issue that could prevent a meter's configuration from being uploaded if the sign-on sequence failed during a history upload and a retry is attempted by ACM. 

ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueCorrects an issue that could cause the polling sequence to an RTU to get out of sync with the RTU resulting in an Invalid Command Error response during sign-on sequence. 

ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueA Time Sync operation will now cause the Call-in Schedule to be set on the RTU when the protocol option "Set call-in schedule after regular polls" is enabled. 

ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueCorrects an issue that caused the RTU call-in to not be acknowledged when no device protocol call-in options were enabled. 

ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueCorrects an issue that could cause the next Call-in Schedule to not be set on the RTU when certain combinations of device protocol call-in options were enabled. 

ACM 9.1Protocols: Honeywell - Mercury ProtocolIssueRemoves the "Change Access" capability for Honeywell Mercury EC350 & ERX350 as it is unsupported by these devices. 

ACM 9.1Protocols: Micro MP3 ProtocolIssueCorrects an issue that prevented the "Contract Hour" from being polled correctly which resulted in the value always being 0 on the Archive Management tab. *Effect On Published Output: Contract hour is now polled correctly and published for Micro MP3 devices.X
ACM 9.1Protocols: Modbus ProtocolIssueCorrects an error that occurred when writing to array item using common Modbus item modifier 'IS'. 

ACM 9.1Protocols: Omni Modbus ProtocolIssuePrevents a Viscosity event in Omni 7000 devices from returning an abnormal code. 

ACM 9.1Protocols: Omni Modbus ProtocolIssueAdds the Calculation Method for the Omni 7000 liquid meter to the published output. *Effect On Published Output: The Calculation Method will now be published for Omni 7000 liquid meters.X
ACM 9.1Protocols: Omni Modbus ProtocolIssueCorrects an issue that could cause an exception while processing an Omni 3000/7000 alarm record. 

ACM 9.1Protocols: Possibly multiple protocolsIssueAdds all Batch Record field identifiers and Liquid Product field identifiers to the selection list in the Archive Field Configuration Record Collection form. 

ACM 9.1Protocols: ROC ProtocolIssueAdds DATABASE.TOTAL_YD back to the OPC browsing list. 

ACM 9.1Protocols: ROC ProtocolIssueCorrects an issue that caused the GCWrite to write to incorrect TLPs if the GCWrite was executed before ROC meter configuration was read. 

ACM 9.1Protocols: ROC ProtocolIssueCorrects an issue that occasionally prevented the driver from determining the appropriate series when the "Do not switch ROC automatically series" was unchecked. 

ACM 9.1Protocols: ROC ProtocolIssueCorrects an issue that left an invalid item in the poll message after an "Invalid TLP" error code. 

ACM 9.1Protocols: ROC ProtocolIssueCorrects an issue where ROC FB103's were being polled as 503's resulting in missing values and no extended records. *Effect On Published Output: Corrects an issue where ROC FB103's were being polled as 503's resulting in missing values and no extended records.X
ACM 9.1Protocols: ROC ProtocolIssuePrevents the option group from scrolling when clicking on an option while the form is not maximized. 

ACM 9.1Protocols: ROC ProtocolIssueAdds a field to the "Device" tab labeled "Schedule Reinitialization" to schedule the Reinitialize command. 

ACM 9.1Protocols: ROC ProtocolIssueUpdates the Internal Archive Map Details pop-up to list EFM Fields according to meter type.  The button to view this list is found on the "Archive Collection" tab. 

ACM 9.1Protocols: SCADAPack ProtocolIssueCorrects an issue that prevented the Scadapack driver from updating the status of a GC Write request if the request failed due to a Comm error. 

ACM 9.1Protocols: SCADAPack ProtocolIssuePrevents a partial meter record from being published if it is missing a Contract Hour. *Effect On Published Output: Partial meter config records that are missing the Contract Hour will not be published.X
ACM 9.1Protocols: Siemens ProtocolIssueCorrects an issue with Byte Bit offsets that caused returned and written values to be off by one index. 

ACM 9.1Protocols: Totalflow ProtocolIssueCorrects an issue where a time sync and history request will fail due to having the same priority schedule. 

ACM 9.1Protocols: Totalflow ProtocolIssueModifies the driver to use the configuration value read from the device for the "Has Default Temperature" field instead of a fixed value. *Effect On Published Output: The meter configuration field "Has Default Value" will display the meter's configured value.X
ACM 9.1Protocols: Totalflow ProtocolIssueCorrects the driver so it will not collect duplicate Alarm Records during log period collection. *Effect On Published Output: Duplicate alarm records will not be published.X
ACM 9.1Protocols: Totalflow ProtocolIssueAdds 'Double' data type support for Totaflow register read and write. 

ACM 9.1Protocols: Weatherford ProtocolIssueCorrects an issue that could cause ACM to stop running if the driver received an unexpected response packet to an FC16EX card buffer upload request. 

ACM 9.1Protocols: Weatherford ProtocolIssueCorrects an issue that could cause the event directory upload to never cease running if the event buffer on the controller was completely full. 

ACM 9.1PublishingIssueIncreases the size of the variables in asi_spgetPublisherFilteredObjects to varchar(max) to process very large filters. Note: After this fix, there is still a SQL Server limitation to varchar(max).  If this error is still seen after DB Version 42, the filter will need to be modified. 

ACM 9.1PublishingIssueAdds logging to the Database output type to show if a transaction was committed or rolled back to show the transaction completed. 

ACM 9.1PublishingIssueAdds the field name and unit of measure to the message that is logged when the publisher cannot validate an event. 

ACM 9.1PublishingIssueCorrects the error that resulted in an "Implicit conversion from data type datetime to real is not allowed." message when publishing a sample date to the FLOWCAL Transaction Queue. *Effect On Published Output: The sample date value from a DNP3 FBx device can now be published.X
ACM 9.1PublishingIssueCorrects the conversion for the Meter Access Date, Cold Start Date, Warm Start Date and Sample Date which are datetime fields but stored as a 'real' value in FLOWCAL. *Effect On Published Output: The Meter Access Date, Cold Start Date, Warm Start Date and Sample Date fields may now have data where previously they were incorrect null or 0.X
ACM 9.1PublishingIssuePrevents a string value from being published as the Contract Hour if an alphabetic character is entered for Contract Hour in the Advanced Meter Config. *Effect On Published Output: The FLOWCAL Transaction Queue will publish a number entered in the Contract Hour of the Advanced Meter Config, and will publish nothing if an alphabetic character is entered.X
ACM 9.1PublishingIssueAdds a fixed/live temperature indicator as TEMP_SOURCE and a fixed/live pressure indicator as SP_SOURCE to the meter characteristics for the PGAS XML publisher. *Effect On Published Output: The PGAS XML output will include fixed/live temperature and fixed/live pressure flags in the meter characteristics element if the protocol driver provides them.X
ACM 9.1PublishingIssueIncludes the values of the User01, User02, and User03 fields from the Details tab, as well as the External GC Reference and External Meter Reference values in the published output. *Effect On Published Output: The User01, User02, User03, External GC Reference and External Meter Reference properties will now have values in the published output.X
ACM 9.1PublishingIssueThe User01, User02, User03, External GC Reference and External Meter Reference properties will now have values in the published output. 

ACM 9.1ReportsIssuePrevents extraneous logs from being written when saving edits to scheduled reports. 

ACM 9.1ReportsIssueCorrects an issue in the Scheduled Reports that caused the $$CurrentDay$$ or $$CurrentHour$$ tokens to be incorrectly calculated in Throughput reports. 

ACM 9.1ReportsIssueCorrects an issue in the Scheduled Reports form that prevented the Save button from being enabled after editing the connection. 

ACM 9.1ReportsIssueModifies the "Configuration Changes for a Device" report to filter to only Device type objects. 

ACM 9.1ReportsIssueAdds a new report titled "Configuration Changes for an Object" to search for configuration changes for any object type. 

ACM 9.1ReportsIssueAdds support for all of the following report formats to both manually run reports and scheduled reports:  CSV, HTML, PDF, XLS, XLSX, & TEXT. 

ACM 9.1ReportsIssueCorrects the Scheduled Report form for the Missing Daily Archive Records to show the saved start and end date parameters when editing the form. 

ACM 9.1Server MonitorIssueAdds the newest Microsoft OLE DB Driver 19 to the available database providers in ACM Monitor. This provides additional encryption options for the connection.  More information can be found in the User Guide. 

ACM 9.1Server MonitorIssueAdds a button to view the connection string. 

ACM 9.1Server MonitorIssueModifies the History Deletion value displayed in the Task Summary field when creating a new ACM database to show HH:MM. 

ACM 9.1Server MonitorIssueCorrects the Write Timeout property of "Gas Analysis Writes Retry" to accept values in the range of 30 to 600 seconds. 

ACM 9.1Server MonitorIssueModifies the password requirements for the database user in ACM Monitor to prevent semi-colons. 

ACM 9.0.1

ACM Server

Issue

Corrects an issue that prevented encrypted channel communication between an ACM client and server when the client and server components are on different computers.



ACM 9.0.1

Bulk Manager

Issue

No longer moves Import files to the Import Failed folder after a SQL Timeout.  Instead they will remain in the Import folder.



ACM 9.0.1

Client Application

Issue

Corrects an issue in the "Password" and "Register Block Read Path" textboxes that did not allow user to enter a value properly.



ACM 9.0.1

Client Application

Issue

Removes the "Retrieve History", "Delete History for Device" and "Republish Device Records" commands from the right-click menu of Real-Time Only devices.



ACM 9.0.1

Client Application

Issue

Corrects an issue when creating a new Port Object that prevented the Port Type from being changed after canceling out of the folder location screen.



ACM 9.0.1

Client Application

Issue

Prevents the Edit Multiple Objects grid from re-sorting the data while a user is typing a value into a cell.



ACM 9.0.1

Client Application

Issue

Corrects an issue that caused the Logger and Queue tabs to go blank when a large number of object tabs were open in multiple ACM Clients.



ACM 9.0.1

Configuration Database

Issue

Corrects an issue in SQLUpdate_39.sql that prevented the ACM database from upgrading to DBVersion 39 and above where the default collation on the SQL Server is SQL_Latin1_General_CP850_BIN.



ACM 9.0.1

Configuration Database

Issue

Increases the size of the LastUpdateUser column in tblProperties and tblObjects, and the size of CfgUser in tblChanges, to nvarchar(100).  Note: If the tables are being replicated, this will not run automatically and instead can be run via the Manual Script feature in ACM Monitor.



ACM 9.0.1

General

Issue

Corrects a memory leak that occurs when logging "data sent to client" on items in the OPC UA interface.



ACM 9.0.1

OPC UA

Issue

Integrates the OPC UA .NET Standard Stack Version  1.4.369.30 from OPC Foundation which fixes the following cybersecurity vulnerabilities: CVE-2022-29862, CVE-2022-29863, CVE-2022-29864, CVE-2022-29865, and CVE-2022-29866.


YES

ACM 9.0.1

Protocols: Base Protocol

Issue

Correctly updates PctBadTries and PctGoodTries if the connection fails before the message can be sent.



ACM 9.0.1

Protocols: Base Protocol

Issue

Correctly updates the port PollAttempts counter when an external interruption occurrs.



ACM 9.0.1

Protocols: Base Protocol

Issue

Prevents queuing an additional demand after Demand is poked to trigger a continuous scan during cry out.



ACM 9.0.1

Protocols: Base Protocol

Issue

Corrects an issue that prevented the PctGoodTries and PctBadTries statistic items from being correctly updated when a connection was dropped before a message could be sent.



ACM 9.0.1

Protocols: BSAP Protocol

Issue

Corrects an issue that caused the driver to ignore the previous position and retrieve all history when the "Disable duplicate record deletion" option was selected.



ACM 9.0.1

Protocols: BSAP Protocol

Issue

Prevents a crash from occurring when the Field Configuration has not been assigned and the device could not be reached.



ACM 9.0.1

Protocols: DNP3 Protocol

Issue

Adds support for new objects, parameters, measurements, units and error codes in Emerson FBx firmware release version 2.9. 

X


ACM 9.0.1

Protocols: DNP3 Protocol

Issue

Handles alarm and event records that occur when the device is configured for BSAP Combined Event Log. *Effect on published output: Correctly publishes alarm and event records.

X


ACM 9.0.1

Protocols: DNP3 Protocol

Issue

Uses meter config file from device to publish string events as well as FLOWCAL events to non-Generic meters. 

X


ACM 9.0.1

Protocols: DNP3 Protocol

Issue

In cases where this can be detected before polling, does not try to retrieve records from empty or unconfigured archives.

X


ACM 9.0.1

Protocols: DNP3 Protocol

Issue

Corrects an issue so that alias items are added correctly via browsing in an OPC client.



ACM 9.0.1

Protocols: DNP3 Protocol

Issue

Corrects an issue that caused incorrect meter configuration values for VersionNumber, CalculationMethod and HeatingValueUnits to be published when using meter config file read from FBx device. *Effect on published output: The values for VersionNumber, CalculationMethod and HeatingValueUnits will be published correctly.

X


ACM 9.0.1

Protocols: DNP3 Protocol

Issue

Changes the dropdown list that selects the meter run into a numeric updown control in the Meter Runs tab.



ACM 9.0.1

Protocols: Flow Automation Protocol

Issue

Corrects an issue that caused YesterdayFlowTime and YesterFlowEnergy to be incorrectly retrieved when the "Retrieve yesterday flow time or energy using history message" option was checked.



ACM 9.0.1

Protocols: Honeywell - Mercury Protocol

Issue

Corrects a potential memory leak.



ACM 9.0.1

Protocols: Honeywell - Mercury Protocol

Issue

Corrects an issue that prevented the Unit types for Pressure and Temperature audit record fields from being published for an ER type device. *Effect on published output: For ER type devices, the Units for Temperature and Pressure fields will now be published.

X


ACM 9.0.1

Protocols: Modbus Protocol

Issue

Corrects the default data type for BlockStart-BlockEnd values to unsigned and adds an "S" item conversion to allow values to be output as signed.



ACM 9.0.1

Protocols: Omni Modbus Protocol

Issue

Corrects an issue that prevented subsequent archives from being requested after processing the GC archive for Archive 1.



ACM 9.0.1

Protocols: Omni Modbus Protocol

Issue

Prevents a crash from occurring when polling raw data upload.



ACM 9.0.1

Protocols: ROC Protocol

Issue

No longer updates the item quality when the "test" of the primary connection fails when using the Auto Recover feature.



ACM 9.0.1

Protocols: ROC Protocol

Issue

Displays the correct log message type in the logger when the "Items in message" log option is enabled.



ACM 9.0.1

Protocols: ROC Protocol

Issue

Corrects an issue in detecting the ROC model type that prevented ROC history collection settings from updating properly.



ACM 9.0.1

Protocols: Totalflow Protocol

Issue

Corrects an issue that prevented LastHourlyRecord/1 from being initialized correctly with the latest hourly record time stamp.



ACM 9.0.1

Protocols: Totalflow Protocol

Issue

Corrects an issue that occurred when the field device handles a request for a history record at the "maximum position" by returning more than one record.



ACM 9.0.1

Protocols: Totalflow Protocol

Issue

Prevents a poll on the primary connection from switching to the secondary connection when an item with the secondary connection specifier failed to poll.



ACM 9.0.1

Protocols: Totalflow Protocol

Issue

Corrects an issue that prevented the daily record from being collected when using the "number of days" method in the DB2 protocol.



ACM 9.0.1

Protocols: Weatherford Protocol

Issue

Corrects an issue that prevented card data from publishing to a database when the number of data points in the card set exceeded the maximum column count of the table. *Effect on published output: When publishing card data using Function Code 25, the position/load data pair field names now starts with "Position0" and "Load0" for each individual stroke record in the card set as opposed to the field name index continuing to increment across the entire card set.

X


ACM 9.0.1

Publishing

Issue

Corrects an issue that prevented FPV Method change events from publishing to the FLOWCAL Transaction Queue. *Effect on published output: Events for changing the FPV Method value will now publish correctly to the FLOWCAL Transaction Queue.

X


ACM 9.0.1

Publishing

Issue

Corrects a PGAS XML publishing issue that created an unnecessary transaction with an empty 'METER' element.



ACM 9.0.1

Publishing

Issue

Prevents the asiPublish process from hanging when asiData is being shut down.



ACM 9.0.1

Publishing

Issue

Corrects an issue that stopped publishing to the FLOWCAL Transaction Queue when a record had an invalid future timestamp.



ACM 9.0.1

Reports

Issue

Logs the query of a scheduled report when the "Report Logging" option is enabled.



ACM 9.0.1

Reports

Issue

Corrects an issue that prevented users from requested unlimited records when running reports.



ACM 9.0.1

Server Monitor

Issue

Corrects an issue in the ACM Database Safe Mode backup that caused the backup to fail if there are orphaned properties or items for a device that does not exist.



ACM 9.0.1Server MonitorIssuePrevents an exception in the Server Monitor that could occur when retrieving ACM license request information when FIPS is enabled in the Group Policy.

ACM 9.0.1

Tools

Issue

Corrects an issue that could cause one OPC item to replace a previous OPC item in the ACM memory. This only affects the 64-bit version of ACM.



ACM 9.0

ACM Server

Issue

Resolves issues related to OPC client browsing when clients use absolute browse paths instead of relative browsing.



ACM 9.0

ACM Server

Issue

Adds information to GC Request logging to indicate where a failure occurred.  GC Status updates that do not change rows will return a DB Error status.



ACM 9.0

API

Issue

Corrects an issue in the API which reported that "Server" objects are creatable.



ACM 9.0

Client Application

Feature

Adds the Object ID and Description to the search results form.



ACM 9.0

Client Application

Feature

Adds a new tool that processes SCADA XML files containing Emerson DNP3 object/parameter names and provides the ability to create, update or replace ACM Alias Group items.



ACM 9.0

Client Application

Feature

Provides the ability to assign multiple alias groups to devices and views.  



ACM 9.0

Client Application

Feature

Adds the ability to assign an Interval to Alias Groups.



ACM 9.0

Client Application

Feature

Adds the feature to drop down boxes on the Reports tab to automatically filter results while typing.



ACM 9.0

Client Application

Issue

Corrects an issue that occasionally caused an incorrect command name to be logged in the database.



ACM 9.0

Client Application

Issue

Corrects the message regarding the maximum number of archive records that can be published from 1000 to 5000 to match the actual functionality.



ACM 9.0

Client Application

Issue

Corrects various forms throughout ACM where fields and buttons were enabled when they shouldn't have been.



ACM 9.0

Client Application

Issue

The Add/Select object window will now retain its size when closed and reopened.



ACM 9.0

Client Application

Issue

Corrects an issue which caused ACM to crash after renaming a device, then renaming its meter to the same name, but saving changes to the meter before saving the device.



ACM 9.0

Client Application

Issue

Prevents invalid data from being saved by disabling the Save button when text is deleted from a required field and when invalid data is entered.



ACM 9.0

Client Application

Issue

Corrects the tab order on the "Database" tab of the configuration form of the $Server object.



ACM 9.0

Client Application

Issue

Prevents ACM Configuration from attempting to use an http port when connecting to ACM if one has not been configured.



ACM 9.0

Client Application

Issue

Displays a new error message when an object name contains a carriage return in the name.



ACM 9.0

Configuration Database

Issue

Adds a setting in ACM Monitor called "Keep Meter History".  By default this is set to true and ACM will continue to keep meter record history as in previous versions of ACM.  If this is unselected, ACM will no longer move meter records into history, and and ACM will only have current meter records.



ACM 9.0

Configuration Server

Issue

Changes the default value for deleting old history to "Disabled".



ACM 9.0

Protocols: SCADAPack Protocol

Feature

Adds support for SCADAPack x70 series RTUs.



ACM 9.0

Protocols: SCADAPack Protocol

Feature

Adds support for RealFlo 7.0.



ACM 9.0

Protocols: SCADAPack Protocol

Feature

Adds support for AGA3-2013.



ACM 9.0

Configuration Database

Issue

Removes the logic from the following deprecated stored procedures: asi_spPubNewRecords, asi_spPubNewMeterRecords, asi_spGetHourlyGapsMain, asi_spGetHourlyGaps, asi_spGetHourly, asi_spGetDailyGapsMain, asi_spGetDailyGaps, asi_spGetDaily, asi_spChildObjects, asi_spDeleteOldArchiveRecords, asi_spDeleteOldArchiveRecords2.  The empty stored procedures will remain in the database as replicated stored procedures cannot be "dropped".



ACM 9.0

Configuration Database

Issue

Modifies the Meter Historization process stored procedure to improve processing speed.



ACM 9.0

Configuration Database

Issue

Deletes Meter Record History rows (in tblMeterRecordsHistory) for meters that do not exist in the ACM configuration.



ACM 9.0

Logging

Issue

Corrects an issue that caused messages to be split into multiple lines in the log file.



ACM 9.0

OPC Items

Issue

Corrects an issue that prevented Detail Items from displaying correctly in an OPC browse.



ACM 9.0

Protocols: Base Protocol

Issue

Corrects an issue that could prevent a device from returning to its regular polling schedule if its alternative schedule was disabled while the device was actively polling on that alternative schedule.



ACM 9.0

Protocols: Base Protocol

Issue

Changes the Quality of Extended Items to "Bad" when a device is disabled and "Good" when the device is enabled. This change affects the ROC, Totalflow, Honeywell Mercury, ControlLogix and Modbus Devices.



ACM 9.0

Protocols: Benchmark Protocol

Issue

Corrects an issue related to writing to multiple items at once that could cause asiData to crash.



ACM 9.0

Protocols: BSAP Protocol

Feature

Adds ControlWave signal items to RBE polls.



ACM 9.0

Protocols: BSAP Protocol

Issue

Corrects an issue that prevented the item value from saving for upload pointer and time sync item reads.



ACM 9.0

Protocols: ControlLogix Protocol

Issue

Corrects an issue in the "Processor Slot Number" field on the device tab that allowed out of range values to be entered.  The valid range is 0 to 255.



ACM 9.0

Protocols: DNP3 Protocol

Feature

Implements items to log FBx meter configuration file data.  These items are: LogMeterFileDP/{meter number}, LogMeterFileLinear/{meter number}, LogMeterFileLiquid/{meter number} and LogMeterFileList.



ACM 9.0

Protocols: DNP3 Protocol

Feature

Adds an option "Use history points from device" to the Archive Collection tab's EFM Options to signify to ACM to use the FBx history header to publish history records. *Effect on published output: When the "Use history points from device" option is selected, the FBx history header will be used to publish history records.

X


ACM 9.0

Protocols: DNP3 Protocol

Feature

Adds an option "Use meter config from device" to the Archive Collection tab's EFM Options to signify to ACM to use the FBx meter config file to: *Read event and alarm records. *Read the meter list and meter config files from the device to determine which items to read and publish as meter configuration records *Effect on published output: When the "Use meter config from device" option is checked, published event, alarm and meter configuration records will be determined by the FBx meter config file.

X


ACM 9.0

Protocols: DNP3 Protocol

Issue

Corrects problems with poll cycle interrupts and DNP3 message sequences that shouldn't be interrupted.



ACM 9.0

Protocols: Flow Automation Protocol

Issue

Corrects an issue that caused duplicate factor events to be published to the FLOWCAL Transaction Queue, which caused the publisher to fail.



ACM 9.0

Protocols: Honeywell - Mercury Protocol

Feature

Adds support for using configurable archive records.



ACM 9.0

Protocols: Honeywell - Mercury Protocol

Feature

Adds OPC item "MoveAudit" that provides the ability to move each Audit pointer to the desired date and time.



ACM 9.0

Protocols: Honeywell - Mercury Protocol

Feature

Adds OPC item "ChangeACS" in order for the user to change the access code.  This is only supported for non-350 series controllers.



ACM 9.0

Protocols: Honeywell - Mercury Protocol

Issue

Corrects an issue that caused gaps to occur in history records after an ACK message timed out. Now, instead of skipping to the next record, the driver will attempt to recollect the previous record.



ACM 9.0

Protocols: Honeywell - Mercury Protocol

Issue

Corrects an issue that could cause an access violation error when certain noise bytes are received in a poll response.



ACM 9.0

Protocols: Honeywell - Mercury Protocol

Issue

Adds a new informational message when time synchronization is completed.



ACM 9.0

Protocols: Micro MP3 Protocol

Feature

Adds the ability to poll and publish alternative (non-truck-loading) batch records. *Effect on published output: Alternative (non-truck-loading) batch records can now be published.

X


ACM 9.0

Protocols: NGCTT Protocol

Issue

Corrects an issue that caused history polling to terminate when 10 04 bytes were returned from a device in the middle of polling.



ACM 9.0

Protocols: ROC Protocol

Feature

Adds compressibility (Zs and Zb) to the meter configuration record for Directive 17 Compliance. *Effect on published output: The compressibility fields (Zs and Zb) of the meter configuration record will now be published.

X


ACM 9.0

Protocols: ROC Protocol

Feature

Adds the ability to process ROC 800 Liquid meter data in the GC Write service.



ACM 9.0

Protocols: ROC Protocol

Feature

Adds support for V-Cone meters.  A new tab for configuring this has been added between the "Meter Runs" and "History Segments" tabs in the ROC configuration. *Effect on published output: V-Cone meter data may now be published.

X


ACM 9.0

Protocols: ROC Protocol

Feature

Adds a new PGAS Output option labeled "Map Volume to INDEX_OFF and 0 to INDEX_ON" for PGAS output. *Effect on published output: If the new option is used, volume will be published to INDEX_OFF and INDEX_ON will be set to zero in the PGAS output.

X


ACM 9.0

Protocols: ROC Protocol

Feature

Adds the ability to collect 'Tap Type' with meter configuration in ROC800 devices. *Effect on published output: Publisher outputs will now include 'Tap Type' in the meter configuration.

X


ACM 9.0

Protocols: ROC Protocol

Feature

Adds the ability to publish Ultrasonic Data to the FLOWCAL Transaction Queue. *Effect on published output: Ultrasonic Data can now be published to the FLOWCAL Transaction Queue

X


ACM 9.0

Protocols: ROC Protocol

Feature

Adds the ability to retrieve HART tags for Process Limits for the meter configuration records of ROC 800 gas and liquid devices.  The HART module in ROC FB107 and any older ROC devices (200's, 300's, 500's) is not supported. *Effect on published output: If configured in the device, HART tags will be used for Process Limits when publishing meter configuration records.

X


ACM 9.0

Protocols: ROC Protocol

Feature

Adds an option to the device tab "Use indicated volume for mass in mass meters." to control whether mass or indicated volume is published as mass for liquid mass meters. *Effect on published output: When the new option "Use indicated volume for mass in mass meters." is selected, indicated volume will be published as mass for liquid mass meters.  If not selected, mass will be published.

X


ACM 9.0

Protocols: ROC Protocol

Issue

Corrects incorrect event mapping for history segment changes in the ROC800 devices. *Effect on published output: ROC800 events for history segment changes are output correctly via CFX and Transaction Queue publishers.

X


ACM 9.0

Protocols: ROC Protocol

Issue

Corrects an issue where mapping and combining points from different segments caused partial records when the segment pointers are misaligned. *Effect on published output: Complete records will be published when mapping and combining points from different segments, even when the segment pointers are misaligned.

X


ACM 9.0

Protocols: ROC Protocol

Issue

ROC Validation of raw TLP OPC tags now takes into account the number and types of meters configured on the device before it attempts to poll them.



ACM 9.0

Protocols: Romet-Adem Protocol

Issue

Corrects an issue that could cause incorrect meter configuration values when using the RD command to read register values after a timeout occurs.



ACM 9.0

Protocols: SCADAPack Protocol

Issue

Corrects an issue that caused GC Write to fail for gas coriolis meter runs on controllers running RealFlo 6.95 or greater.



ACM 9.0

Protocols: SCADAPack Protocol

Issue

Corrects an issue that could cause an incorrect pipe material to be published. *Effect on published output: The correct value for Pipe Material will be published.

X


ACM 9.0

Protocols: SCADAPack Protocol

Issue

Modifies the driver to use the correct registers for reading and writing heating value and gas density value.



ACM 9.0

Protocols: Scancom Protocol

Issue

Corrects an issue that prevented "Trusted Log In" from being enabled once it had been disabled.



ACM 9.0

Protocols: Scancom Protocol

Issue

Changes the "Read Only" state on FRDM items to reflect Barton documentation.



ACM 9.0

Protocols: Scancom Protocol

Issue

Corrects an issue when writing to multiple items at once that caused the message to be too large for the PLC to process.  This resulted in no response and communication failure.



ACM 9.0

Protocols: Teledyne CA Protocol

Issue

Corrects an issue in the driver that could prevent items of higher cards and points from being polled, which resulted in invalid item values.



ACM 9.0

Protocols: Totalflow Protocol

Issue

Corrects an issue that caused the "Use FT" and "Use FB" event values to be incorrectly formatted when publishing to CFX or Transaction Queue. *Effect on published output: The "Use FT" AND "Use FB" event values will be correctly formatted when publishing to CFX or Transaction Queue.

X


ACM 9.0

Protocols: Totalflow Protocol

Issue

Adds the Trend Record Type to the trends tab form view. It previously only existed in the Property Grid view.



ACM 9.0

Protocols: Weatherford Protocol

Feature

Adds a Weatherford 8500 protocol module to communicate with Weatherford WellPilot RPOC, ePic VSD, ePic RPC, M8800, M8750, M2000, M8650, M8500, and EXS-1000 ESP. Other devices that use the same Weatherford/Baker/eProd 8500 protocol, or use protocol simulators, are also supported.



ACM 9.0

Protocols: Weatherford Protocol

Feature

Optimizes the performance for OPC synchronous read from device requests.



ACM 9.0

Protocols: Weatherford Protocol

Issue

Corrects an issue that could cause card data reports to publish to the wrong file if more than one device object is configured to use the same meter object.



ACM 9.0

Publishing

Feature

Adds an option to the PGAS XML output type labeled "Create files per record type" to store meter characteristic records separately from other record types. If enabled, meter characteristics records will be stored in their own file. All other record types (volume, alarm, event and quality) will be stored together. *Effect on published output: If the new PGAS XML option "Create files per record type" is selected, meter characteristic records will be stored separately from other record types in PGAS XML published outputs.

X


ACM 9.0

Publishing

Feature

Field records of an Archive Field Configuration object can now be selectively configured to be skipped when publishing the EFM record. *Effect on published output: Protocols that use a configurable archive object can now be configured to selectively skip EFM record fields when publishing.

X


ACM 9.0

Publishing

Issue

Corrects the default order of archive records in CFX outputs when publishing meters only. *Effect on published output: The sort order of CFX output when publishing "Meters Only" will always be by "RecordTS".

X


ACM 9.0

Publishing

Issue

Corrects an issue that prevented the Contract Hour and Contract Day fields from being output to the FLOWCAL Transaction Queue. *Effect on published output: The Contract Hour and Contract Day will be output to FLOWCAL Transaction Queue.

X


ACM 9.0

Publishing

Issue

Corrects the mapping of the SP and DP calibration values so they are output correctly in the PGAS publisher. *Effect on published output: The correct values for SP and DP calibration will now be output in the PGAS XML publisher.

X


ACM 9.0

Reports

Issue

Optimizes the performance of retrieving and displaying report data.



ACM 9.0

Reports

Issue

Changes the heading of the 'Date' column in the Configuration Change Reports to 'Date (UTC)'.



ACM 9.0

Reports

Issue

Corrects an issue that could cause a scheduled report to run at least once a minute  - ignoring the "sync time".



ACM 9.0

Server Monitor

Issue

Provides a manual update script to change the tblItems ID column to a BIGINT if the column was not upgraded due to the table being replicated.  This can only be run once the tblItems table is removed from the replicated articles.



ACM 9.0

Server Monitor

Issue

Corrects an issue that prevented services from being started via the Server Monitor if the user for the ACM services did not already have the "Log on as a service" right.



ACM 8.2.1

ACM Server

Issue

Corrects a property load error that can occur when processes ACM relies upon aren't available.



ACM 8.2.1

Client Application

Issue

Corrects an issue that prevented using the "Edit Multiple" feature to edit the Protocol Options on multiple New Honeywell Mercury devices.



ACM 8.2.1

Client Application

Issue

Removes erroneous log messages that were displayed when writing to an item with "ReadUserOnly" disabled.



ACM 8.2.1

Client Application

Issue

Corrects the tool tip message for the Details tab User01 property.



ACM 8.2.1

Client Application

Issue

Corrects the checkbox list initial focus issue on multiple tabbed pages



ACM 8.2.1

Client Application

Issue

The date-time parameters in reports will now correctly display the saved date and time when editing a scheduled report.



ACM 8.2.1

Configuration Database

Issue

Improves performance of the Archive Management/Gap Detection Process.



ACM 8.2.1

Configuration Database

Issue

Improves performance of resetting a publisher, both with and without a filter.  Note:  Will be more efficient if appropriate indexes exist on the tables.  Run the manual update script to create missing indexes.



ACM 8.2.1

Configuration Database

Issue

Improves overall publishing performance. Note:  Will be more efficient if appropriate indexes exist on the tables.  Run the manual update script to create missing indexes.



ACM 8.2.1

Configuration Database

Issue

Adds three reports for verifying data and schema integrity.   -The "Data Integrity Report" returns information regarding potential errors in the configuration. -The "Frequent Alarm and Event Report" returns information regarding meters with alarms and events above a given quantity . -The "Database Schema Integrity Report" returns details about the production schema that does not match the installed ACM version such as missing or mismatched indexes and triggers.



ACM 8.2.1

Configuration Database

Issue

Adds a table to the ACM Database for keeping track of database version history.



ACM 8.2.1

Configuration Database

Issue

Provides a script to create all expected but missing indexes on ACM tables.



ACM 8.2.1

Configuration Database

Issue

Modifies the stored procedure that is responsible for deleting archive records to make it more efficient.



ACM 8.2.1

Connection: Base Connection

Issue

Increases the Connection Settings Reply Timeout maximum value from two minutes to three minutes.



ACM 8.2.1

Connection: Serial Connection

Issue

Corrects an issue that prevented saving configuration changes in Serial Ports.



ACM 8.2.1

Connection: TCP Listen Connection

Issue

Corrects a crash in connection modules that occurred during poll interruption.



ACM 8.2.1

GC Write Service

Issue

Corrects an issue to prevent GC Write Requests from getting stuck after 32,767 retries when using "slow mode".



ACM 8.2.1

General

Issue

Corrects the OPC item ->Server/CfgCount value update when multiple ACMConfig Clients are connected.



ACM 8.2.1

General

Issue

Corrects an issue that allowed Async Writes from an OPC client when they should have been blocked.



ACM 8.2.1

General

Issue

Corrects an issue that could cause the initial OPC refresh to fail when used by a managed language client.



ACM 8.2.1

Configuration Database

Issue

Modifies the meter historization process to run in a stored procedure instead of a trigger to prevent issues with replication and clustering.



ACM 8.2.1

Configuration Database

Issue

Modifies the meter historization process to only keep unique meter FieldData



ACM 8.2.1

Protocols: Honeywell - Mercury Protocol

Issue

Corrects an issue that resulted in response packet noise byte characters being included in the CRC calculation.



ACM 8.2.1

Protocols: Honeywell - Mercury Protocol

Issue

Corrects an issue that could result in a failed EFM upload completing with a Successful Poll result.



ACM 8.2.1

Logging

Issue

Corrects a crash in asiLOGSERVER service.



ACM 8.2.1

Protocols: Benchmark Protocol

Issue

Corrects an issue that caused asiData to hang when uploading history from a Benchmark device if the server did not have DST setup.



ACM 8.2.1

Protocols: ControlLogix Protocol

Issue

Corrects an issue with Bit offsets for INT data types that stopped getting read updates after being written to with the Verify Writes option enabled.



ACM 8.2.1

Protocols: ControlLogix Protocol

Issue

Corrects an issue where invalid messages present in the buffer could cause validation logic to hang up the polling engine.



ACM 8.2.1

Protocols: ControlLogix Protocol

Issue

Lowers the Timeout Multiplier for CIP connections to help avoid running out of connection resources during rapid polling schedules.



ACM 8.2.1

Protocols: ControlLogix Protocol

Issue

Adds a new option to "Invalidate read items on Forward Open failures". When selected, the driver will Invalidate read items on Forward Open connection errors that are non-recoverable, resulting in no poll messages with item value updates during that poll cycle attempt. Improved logging details for Forward Open connection errors.



ACM 8.2.1

Protocols: Enron Modbus Protocol

Issue

Corrects an issue where EFM configuration requests were being built individually, even when poll block was enabled and registers were within range.  Now these will be built as combined messages for Enron, Kinder Morgan, Prosoft, Scadapack and Scanner1150 Modbus protocol.



ACM 8.2.1

Protocols: Flow Automation Protocol

Issue

Modifies the driver to output the correct meter configuration record for Coastal Flow device type.



ACM 8.2.1

Protocols: FlowX Protocol

Issue

Provides missing device destination IP and Port as part of requested message to meet possible firewall rules.



ACM 8.2.1

Protocols: FlowX Protocol

Issue

Corrects an issue that could prevent history collection when not using an alarm map.



ACM 8.2.1

Protocols: Honeywell - Mercury Protocol

Issue

Corrects an issue that prevented items from being successfully added during a restart of ACM if the device firmware did not support the new RG command.



ACM 8.2.1

Protocols: Honeywell - Mercury Protocol

Issue

Modifies the driver to correctly handle an error returned during an ACK or NAK request so that a poll cycle retry will be triggered.



ACM 8.2.1

Protocols: Honeywell - Mercury Protocol

Issue

Modifies several protocols such as the new Mercury protocol and Omni protocol to update meter record time stamp after recollection. *Effect on published output: Meter configuration records will be republished after re-collection without requiring a restart of asiData.

X


ACM 8.2.1

Protocols: Honeywell - Mercury Protocol

Issue

Corrects an issue that prevented messages from being consolidated after items were removed.



ACM 8.2.1

Protocols: Honeywell - Mercury Protocol

Issue

Corrects an issue when writing TS, GCWrite and NextCallinSchedule that prevented the write message from using the configured access code.



ACM 8.2.1

Protocols: Modbus Protocol

Issue

Corrects an error that prevented using the modbus "block read" item.



ACM 8.2.1

Protocols: ROC Protocol

Issue

Corrects a logger warning message which resulted when some ROC configurations published meter configuration information.



ACM 8.2.1

Protocols: Scancom Protocol

Issue

Corrects an issue with variable length strings in EFM records that resulted in reading incorrect characters from the buffer beyond the record. *Effect on published output: Invalid characters from the buffer will no longer be output in a variety of record types.

X


ACM 8.2.1

Protocols: Scancom Protocol

Issue

Corrects an issue with Demand GC message not correctly building for Adept 4.0 message format.



ACM 8.2.1

Protocols: Scancom Protocol

Issue

Corrects OPC validation of hardware items so that they will will not be added if parameter and slot are not entered correctly.



ACM 8.2.1

Protocols: Scancom Protocol

Issue

Modifies the driver so that items not updated due to an error with an item id in a read are now marked as invalid.



ACM 8.2.1

Protocols: Siemens S7 Protocol

Issue

Adds configuration settings to directly control TSAP values on S7-200 model connections.



ACM 8.2.1

Protocols: Totalflow Protocol

Issue

Corrects the log messages displayed when executing the "Retrieve Meter config during next history poll" and "Reset History (LogPeriod/Daily/Event) Pointer" commands.



ACM 8.2.1

Protocols: Totalflow Protocol

Issue

Corrects an issue in the meter configuration record where multiple sets of duplicated fields were output when using the Number of Days history collection option. *Effect on published output: Meter Configuration records will no longer contain multiple duplicate fields.

X


ACM 8.2.1

Publishing

Issue

Corrects an issue that could cause the FlowCal Transaction Queue publisher to insert a zero into a GC or history field when the field has no value. *Effect on published output: Empty GC and history record fields will now be blank instead of displaying a 0 in the Flowcal Transaction Queue.

X


...