Property

Description

Name

The name of this item

Enabled

If checked the Edge ACM will poll this device when running

Publish Rate

The time, in milliseconds, between Device Data Messages

Alter Publish Rate on Point Limits

If enabled, tag limits are monitored by the publisher and the publisher will switch to the Altered Publish Rate if any tag is out of limits

Altered Publish Rate

The time, in milliseconds, between Device Data Messages if any tags assigned to this device are out of limits (Limits are set on the tag object)

Device Address

The Modbus unit address of the device, valid values 0-65535

Modbus TCP

Sets the Modbus message encoding to TCP enabled

Register Set

Defines the specific register set to use when polling the device. Eight register sets are currently included with the application (definitions found below table):

  • AutoPILOT Pro

  • Daniels ASCII

  • Daniels RTU

  • Enron

Modbus RTU
  • Flow Automation

  • Modbus ASCII

Daniels
  • Modbus RTU

Daniels ASCII
  • OMNI

  • Flow Automation

  • AutoPILOT PRO
    • ROC

    • Custom

    Custom Modbus Register Set

    The Modbus Register Set object associated with this device if Custom is selected in the Register Set above.

    Addressing Type

    Defines the End Device addressing type for special configurations of Modbus. There are four options to choose from:

    • None

    • 2byte

    ,
    • SCADAPack

    • Lufkin

    Null Terminated Strings

    Determines if the string registers will be null terminated when written

    Tag Groups

    The Tag Group(s) that are associated with this device. Edge ACM will only poll this device for the tags in the groups

    hilighted

    listed here

    Connection Settings

    The object that contains the connection settings Edge ACM will use to connect to the End Device

    Folder

    The parent folder for this item