Date: Thu, 28 Mar 2024 12:57:50 +0000 (UTC) Message-ID: <1516964078.161.1711630670500@d3653f872255> Subject: Exported From Confluence MIME-Version: 1.0 Content-Type: multipart/related; boundary="----=_Part_160_1051460896.1711630670500" ------=_Part_160_1051460896.1711630670500 Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable Content-Location: file:///C:/exported.html
If you have a support agreement, the new ACM version can be downloaded b= y using the monthly login credentials received from your sales representati= ve. For more details, please contact us today. &nbs= p;
Components from ACM 8 cannot be combined with components from ACM 7.
ACM now provides security options to control access to ACM from the desk= top configuration program and from the mobile app. This also includes an op= tion to control whether administrator accounts have access to ACM.
When security is enabled and this option is not selected, it is possible= to configure users and roles such that all users are locked out of the ser= ver or that no users can change the configuration.
Supports both the truck ticket mode and the full six meter flow computer= mode.
Provides the ability to retrieve and publish daily and monthly batch rep= ort records.
Allows for time synchronization.
Adds support for a comma separated list to be used as the Area ID in que=
ries against the Flowcal database for GC Writes. This allows multiple Areas=
to use the same ACM Server for GC Writes.
Logging
Adds the assembly version number to the source column in the Log Viewer.=
Adds the device detail tab fields as OPC Items.
Adds the ability for a user to separately configure whether Serial or Et= hernet protocol is used on the primary and/or secondary connections.
Adds support for array items to meter configuration polling.
Adds a configuration item token number to each meter run. This number wi= ll be used to replace a token in the items for the meter configuration read= s and GC writes, so that a single Meter Configuration or Gas Chromatograph = object can be used for multiple meter runs.
Adds a rule option in the Meter Configuration object for yes/no fields a= nd RelativeDensitySaturationCondition.
Makes FactorFwv and FwvFactorUsed fields interchangeable.
When a Meter Configuration object (the Advanced Configuration assigned t=
o the Meter object) is used to publish meter configuration data, the fields=
below now use predefined constants for the "Constant" and "Rule" options. =
For the CSV publisher, that means that these values will be published as th=
e text strings "Yes"/"No" (or "Wet"/"Dry"/"AsDelivered" for RelativeDensity=
SaturationCondition) if translation is used, and as numeric codes if transl=
ation is not used. For the XML publisher, all of the fields below will be n=
ow published within the <Common> node, rather than the <Extended&g=
t; node as some of them were before:
FlowingPressureEffectEnabled, Live Analysis, Live BTU, Live Gravity, Live T=
emperature, HasDefaultTemperature, UseRTD, FwvFactorUsed, FwvsFactorUsed, H=
asRTD, TemperatureCompensated, PressureCompensated, FactorFa, FactorFb, Fac=
torFg, FactorFpv, FactorFr, FactorFt, FactorFwv, FactorY, RelativeDensitySa=
turationCondition
Adds support for new objects, parameters, measurements, and units in Eme=
rson FBx firmware through 02.07.00.80.
Adds history collection support for the Flow Automation Williams Gas loa= d.
The CFX publisher will now show valid data for GC data in the meter conf= iguration section where previously it was invalid.
Adds read and write item support for function types Plunger Lift (config=
and instantaneous) and Drip Control for Flow Automation devices with the C=
oastal Flow load.
FlowX Protocol
Adds a new command that allows for copying an existing tag file from a c= onfigured device.
Adds support for Dynamic Flow Computer's MicroMP3 Liquid Flow Computer u= sing the Modbus/MicroMP3 protocol.
MicroMP3 supports both the truck ticket mode and the full six meter flow= computer mode.
MicroMP3 provides the ability to retrieve and publish daily and monthly = batch report records.
MicroMP3 allows for time synchronization.
Adds a new option "Combine data from all segments into the same archive = records" to combine a meter's data from different segments into the same re= cord.
If the new option "Combine data from all segments into the same archive = records" is selected and the user has a meter mapped with fields in differe= nt segments, then the fields will be combined into the same record.
Adds more units for ROC meter configuration such as differential pressur= e units, uncorrected volume units to the CFX Output.
For ROC meter configuration, more units (such as differential pressure u= nits, uncorrected volume units) will be output.
Adds the ability to set a ROC device date/time to any value required via= new Extended OPC tag ClockSet.
Adds support for publishing data to Flowcal Ultrasonic Diagnostic area.<= /p>
Published output will only be affected if customers map the new Ultrason= ic EFM IDs to historized points.
Adds the ability to upload batch history records.
Historical batch records can now be published.
Adds the ability to retrieve a specific bit address and width from Analo= g, Greycode and Digital items.
Adds 'TIMESTAMP' and 'TIMESTAMPUTC' modifiers for app.array.index items = to provide date/time in local and UTC timestamp format.
Adds the ability to use tokens in the form $$Fieldn$$ (where 'n' represe= nts the one-based index of a field in a history record) in a path or file n= ame of the CSV publisher.
When the new token is used in a path or file name of the CSV publisher, = the CSV output will be split into multiple files and/or folders according t= o the field value.
Adds non-configuration and DPTransducerRangeLow events for CFX7/CFX8.
Some events that were not previously published as CFX events now will be= .
Improves error messages generated by the PGAS XML publisher by providing= more detail in the logged message.
Provides an option to adjust the timestamp of gas quality records publis= hed through the PGAS XML output object.
The timestamp of gas quality records will be published according to the = PGAS XML setting.
Adds new security options to control access to ACM from the desktop conf= iguration program and from the mobile app. This also includes an option to = control whether administrator accounts have access to ACM. Note that with t= hese new settings, it is possible to leave the server in a state where no o= ne has permission to change any configuration, or even access the server. Server Monitor
Adds the ability to run individual SQL scripts via the ACM Monitor Datab= ase Wizard.
Adds the ability to save a custom database connection setting in the ACM=
Monitor.
Adds a new option "Delay polling on same connection" to the TCP Listen c= onnection to delay polling a device if it uses the same connection as anoth= er device that is currently polling, even if there is a session available. = This will prevent multiple conflicting connections to the same IP address a= nd Port.
Adds a property to the TCP Listen connection object to configure an init= ial data timeout after an incoming socket connection is accepted.
Adds validation to the Missing Hourly and Daily calculation for Archive = Management in order to handle a scenario in which the same meter is being u= sed on multiple devices
Modifies the Alias Group validation to prevent empty alias and item name= s from being saved.
Modifies the ACM security login to accept "." in the user object's domai= n name.
Corrects an issue that could cause replication to fail if the tblMeterRe= cordsHistory is being replicated.
Corrects an issue that prevented items in the $Perf object from being va= lidated and added from OPC clients.
Modifies the client application to display the "Out of Sync" message on = an open form if that object was modified during an import.
Modifies the OPC test client to allow for a value to be written to an it= em more than once, even if the value didn't change.
Standardizes the initialization of writeable Extended items to "Good" qu= ality.
Adds support for user strings and user doubles to GC write.
In situations where two responses are in the buffer at the same time, th= e driver will move over the first packet and validate the second one as the= response to process.
Converts new DNP3 FBx unit types for use in the ACM publishers.
Adds FBx to ACM unit mappings that were left out of previous updates.
History fields may be published with new unit types.
Corrects a GC Write issue in the Williams Gas Load that could cause the = GC Write to fail after reading partial GC items.
Adds validation to the Flow-X History Map to prevent duplicate Field Ide= ntifiers from being used.
Corrects an issue that prevented writes to device configuration items un= less the ACM license has the 'history' feature enabled.
Adds stricter validation on ROC T.P:L items.
Corrects an issue where external mapping with an EFM ID of UNKNOWN produ= ced unexpected results.
Corrects an issue where an external mapping with the ACM field identifie= r "Unknown" could cause incorrect results in published history records.
=Corrects an issue where configuring a "First Collection Count" of 0 caus= ed no records to be retrieved. Instead, a limit of 0 is now treated as if n= o limit is defined and all available records will be collected.
When the archive limit is set to zero, all records will be returned.
Corrects an issue where some history point mappings could lead to sporad= ic partial history records.
This corrects an issue where some history point mappings can lead to spo= radic partial history records.
Corrects an issue in referenced object text boxes that caused names to b= e truncated in the display.
Adds Flow Time to the CFX8 batch records.
Flow Time will now be included in CFX8 batch records.
Adds the ability to delete history on a hourly interval. This option is = found in the Manage Database wizard of ACM Monitor.
Corrects an issue that prevented items in the "Alias" branch from displa= ying correctly when browsing ACM from Ignition.
Improves the description for the FlowCal Area Index property.
Prevents a TCPIP Listen connection attempt from lasting more than two mi= nutes.
Prevents a TCPIP connection attempt from lasting more than two minutes.<= /p>